• Title/Summary/Keyword: self calibration

Search Result 186, Processing Time 0.027 seconds

Systematic error calibration of 2-axis lateral shearing interferometer (2축 층밀리기 간섭계의 계통오차 보정)

  • 김승우;이혁교
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.98-104
    • /
    • 2002
  • We present a new self-calibration method to remove the systematic error of a 2-axis lateral shearing interferometer that has been specially designed for optical testing of aspheric optics. The method takes multiple measurements by rotating the test optics and extracts the systematic error by fitting the measured wavefronts into the Zernike polynomials. The method works with arbitrary azimuthal angles for test optics rotation, which offers an advantage of correcting the error induced by the non-orthogonality of the two axes of wavefront shearing as well as the error caused by the optical components of the interferometer system itself.

Development of a Time-selective Self-triggering Water Sampler and Its Application to In-situ Calibration of a Turbidity Sensor

  • Jin, Jae-Youll;Hwang, Keun-Choon;Park, Jin-Soon;Yum, Ki-Dai;Oh, Jae-Kyung
    • Journal of the korean society of oceanography
    • /
    • v.34 no.4
    • /
    • pp.200-206
    • /
    • 1999
  • Seawater sampling is the primary task for the study of the marine environmental parameters that require shipboard or laboratory experiments for their analyses, and is also required for the calibration of some instruments for in situ measurement. A new automatic bottle (AUTTLE) is developed for seawater sampling at any desired time and water depth by self-triggering. Both any type of single or assembled mooring for 15 days and manual actuation by using a remote messenger as existing instantaneous single point water samplers are possible. Its sampling capacity and the resolution of time setting are 2 liters and 1 second, respectively. The result of a field experiment with an optical backscattering sensor (OBS) and a total of 14 AUTTLES for the in situ calibration of the OBS shows that the AUTTLE must improve our understanding on the behavior of the sand/mud mixtures in the environments with high waves and strong tides. The AUTTLE will serve as a valuable instrument in the various fields of oceanography, especially where synchronized seawater sampling at several sites is required and/or the information in storm period is important.

  • PDF

An 8-b 1GS/s Fractional Folding CMOS Analog-to-Digital Converter with an Arithmetic Digital Encoding Technique

  • Lee, Seongjoo;Lee, Jangwoo;Lee, Mun-Kyo;Nah, Sun-Phil;Song, Minkyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.473-481
    • /
    • 2013
  • A fractional folding analog-to-digital converter (ADC) with a novel arithmetic digital encoding technique is discussed. In order to reduce the asymmetry errors of the boundary conditions for the conventional folding ADC, a structure using an odd number of folding blocks and fractional folding rate is proposed. To implement the fractional technique, a new arithmetic digital encoding technique composed of a memory and an adder is described. Further, the coding errors generated by device mismatching and other external factors are minimized, since an iterating offset self-calibration technique is adopted with a digital error correction logic. A prototype 8-bit 1GS/s ADC has been fabricated using an 1.2V 0.13 um 1-poly 6-metal CMOS process. The effective chip area is $2.1mm^2$(ADC core : $1.4mm^2$, calibration engine : $0.7mm^2$), and the power consumption is 88 mW. The measured SNDR is 46.22 dB at the conversion rate of 1 GS/s. Both values of INL and DNL are within 1 LSB.

Self-Calibration of a Rotating and Zooming Camera (회전과 줌을 하는 카메라의 Self-Calibration)

  • 서용덕;홍기상
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10c
    • /
    • pp.405-407
    • /
    • 1998
  • 이 논문에서는 회전과 줌을 하는 카메라의 내부변수를 3차원 패턴 없이 주어진 영상만을 이용하여 구하는 방법을 제안한다. 먼저, 카메라의 skew를 0으로 가정하면 카메라의 내부변수가 매 영상취득 시점마다 바뀌어도 그 값들을 구할 수 있다는 것을 이론적으로 보인다. 이때 구해지는 회전 행렬을 기준 좌표계를 설정하는데 따라 달라질 뿐이다. 카메라 보정은 획득되어진 영상 사이의 투영변환행렬을 분석하여 얻어지며, 이는 회전하는 카메라에서 얻어진 두 영상 사이에는 투영변환행렬이 존재한다는 것을 이용한 것이다. 가장 일반적인 경우, 즉 카메라의 skew를 0으로 가정하면, 카메라 내부변수를 계산하기 위하여 모두 네 개의 투영변환행렬이 필요하며, 가장 단순한 카메라 모델의 경우 principal point와 aspect ratio 가 변화하지 않으면 단지 한 개의 투영거리변환이 필요하다. 합성 데이터와 실제 영상 데이터를 이용하여 제안하는 알고리듬을 시험하였다.

  • PDF

3D Surface Model Generation of Micro Structure by Self Calibration of The SEM Image (SEM 영상의 자체검정에 의한 미세구조물의 3차원 표면모델 생성)

  • 이효성;박형동
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.151-159
    • /
    • 2003
  • This study presents method for self-calibration of the SEM(Scanning Electron Microscope) stereo image using the standard microprobe with same grid pattern and using parallel and central perspective projection equation. Result showed that parallel projection method is more suitable for standard microprobe. The maximum error of 3D coordinates acquired by this method did not exceed 5 $\mu\textrm{m}$, and DSM(Digital Surface Model) for three dimensional measurement of the rock sample was generated by the digital photogrammetry. This result can be used for quantification of micro scale change of shape and analysis of the micro morphology of rock due to weathering.

  • PDF

Self-Compensation of PZT Errors in White Light Scanning Interferometry

  • Kang, Min-Gu;Lee, Sang-Yoon;Kim, Seong-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.35-40
    • /
    • 1999
  • One of main error sources in white light scanning interferometry is the inaccuracy of scanning mechanisms in that PZT(piezoelectric transducer) micro-actuators are preferably used. We propose a new calibration method that is capable of identifying actual scanning errors directly by analyzing the spectral distribution of sampled interferograms. This calibration provides an effective means of self-compensation for the non-linearity errors caused by PZT hysteresis, enhancing the measurement uncertainty to a level of 5 nanometers over an entire measuring range of 100 ${\mu}{\textrm}{m}$.

A Study on the Implementation of an Integrated Digital Photogrammetric System

  • Lee, Sulk-Kun
    • Korean Journal of Geomatics
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • An object-oriented design was carried out for the digital photogrammetric processes. Classes were identified and implemented to develop an integrated digital photogrammetry system using a 3 dimensional self-calibration model for CCD cameras. This integrated system is deemed to be a significant progress from the conventional photogrammetric system which is a series of discrete processes. Object oriented methodology was selected for the implementation of the integrated photogrammetric system because it would be a very complex task to get the same result using a procedural programming language. Besides the simplification of development effort, object oriented methodology has further benefits of better management of program in case when updates to parts of the program are necessary. Using the classes designed in this study, a 3 dimensional self-calibration model was developed for a CCD camera. Classes for data input and image handling as well as classes for bundle adjustment were implemented. The bundle adjustment system was further enhanced with member functions to handle additional parameters for principal point coordinates and focal length, thereby, enabling the application to non-metric CCD cameras.

  • PDF

Error analysis and Performance test of the Volumetric interferometer for Absolute distance measurement (삼차원 좌표 측정을 위한 부피 간섭계의 오차분석 및 성능평가)

  • Rhee, H.G.;Chu, J.Y.;Kim, S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, we accomplish uncertainty evaluation and performance test of the volumetric interferometer using two spherical wavefronts emitted from the ends of two single mode fibers. We verify that the volumetric interferometer has the volume uncertainty of 690nm through the error analysis and it has the resolution of 0.1 0.1$\mu\textrm{m}$ for x axis which is the same order of repeatability for x axis. Also, we obtain the systematic error of $1\mu\textrm{m}$ for $60\times 60\times 20 mm^3$ working volume using self-calibration with an artifact plate.

  • PDF

A 10-b 500 MS/s CMOS Folding A/D Converter with a Hybrid Calibration and a Novel Digital Error Correction Logic

  • Jun, Joong-Won;Kim, Dae-Yun;Song, Min-Kyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • A 10-b 500 MS/s A/D converter (ADC) with a hybrid calibration and error correction logic is described. The ADC employs a single-channel cascaded folding-interpolating architecture whose folding rate (FR) is 25 and interpolation rate (IR) is 8. To overcome the disadvantage of an offset error, we propose a hybrid self-calibration circuit at the open-loop amplifier. Further, a novel prevision digital error correction logic (DCL) for the folding ADC is also proposed. The ADC prototype using a 130 nm 1P6M CMOS has a DNL of ${\pm}0.8$ LSB and an INL of ${\pm}1.0$ LSB. The measured SNDR is 52.34-dB and SFDR is 62.04-dBc when the input frequency is 78.15 MHz at 500 MS/s conversion rate. The SNDR of the ADC is 7-dB higher than the same circuit without the proposed calibration. The effective chip area is $1.55mm^2$, and the power dissipates 300 mW including peripheral circuits, at a 1.2/1.5 V power supply.