• 제목/요약/키워드: scanning microscope

검색결과 3,834건 처리시간 0.028초

형광등용 안정기의 발화 및 용융흔 분석에 관한 연구 (A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp)

  • 최충석;박창수;김혁수;김향곤;정재희
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 추계 학술논문발표회 논문집
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구 (A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator)

  • 윤선현
    • 한국광학회지
    • /
    • 제10권4호
    • /
    • pp.267-272
    • /
    • 1999
  • 근접장광학계 (Near-Field Scanning Optical Microscope :NSOM)의 표본과 팁의 거리 유지를 위해 소리굽쇠모양의 수정발진자 (tuning forktype quartz crystal unit)의 한쪽 다리에 광섬유를 고정시키고 광섬유 팁을 수정발진자와 같이 진동하게 만들어 사용하였다. 수정 진동자는 광섬유 팁이 시료에 얼마나 가까이 갔느냐에 따라 진폭이 바뀌게 되고 이 변화를 일반적인 방법인 레이저 빛에 의하여 읽어내는 것이 아니라 바로 수정 발진자의 임피던스 변화에 따른 전압 변화를 측정하여 알아냈다. 팁이 표면에 접근함에 따라 수정발진자 진동폭의 변화와 팁을 통해 들어오는 빛의 세기 변화 등을 측정하여 계의 감도를 조사하였다.

  • PDF

초고진공 Scanning Tunneling Microscope의 제작 (Construction of Ultra High Vacuum Scanning Tunneling Microscope)

  • 손은숙;홍영규;박찬
    • 한국진공학회지
    • /
    • 제3권4호
    • /
    • pp.377-381
    • /
    • 1994
  • 초고진공(UHV) Scanning Tummeling Microscopy(STM)을 제작하였다. 8인치 프란지에 부착한 STM은 초고진공에서 시료의 통전가열이 가능하며 다른 표면 측정방법의 적용과시료처리가 용이하다. 외부로부터 초고진공을 깨지 않고 시료와 tip의 도입이 가능하며 tip을 가열할 수 있다. 완성된 장치로 Si(111)-7$\times$7 구조의 STM상을 얻었다.

  • PDF

근접장 주사 광학현미경을 이용한 광 도파로 특성 연구 (Characterization of optical waveguides with near - field scanning optical microscope)

  • 지원수;김대찬;이승걸;오범환;이일항
    • 한국광학회지
    • /
    • 제13권4호
    • /
    • pp.301-307
    • /
    • 2002
  • 광 도파로를 따라 전파하는 빛의 특성을 측정하기 위해 근접장 주사 광학현미경(Near-field scanning optical microscope, NSOM)으로 광 도파로의 표면에 형성된 에바네슨트 파 evanescent wave)의 분포를 측정하였다. 사용된 NSOM은 photon scanning tunneling microscope방식으로 본 연구의 목적에 적합하도록 직접 제작한 것이다. 광원 파장 1550㎚에서 단일 모드 다중 모드 채널형 광 도파로에 대해 도파로 표면에 형성된 에바네슨트 파의 분포를 측정하였으며, 3차원 빔전파방법(Beam Propagation Method)으로 계산된 수치 해석 결과와 두 모드 간의 간섭 형상을 직접적으로 확인할 수 있었다.

ZnO를 이용한 초음파 현미경의 제작과 평가 (Scanning Acoustic Microsope System Using 200MHZ ZnO Transducer)

  • 장지원;도시홍;이종규
    • 수산해양기술연구
    • /
    • 제25권4호
    • /
    • pp.200-208
    • /
    • 1989
  • 200MHz ZnO변환기를 이용하여 초음파 현미경을 제작하여, 도미비늘을 화상화하고 광학현미경에 의한 사진과 비교하였다. 그 결과 광학적 반사에 의한 표면의 화상과 초음파의 기계적 탄성적 표면하 반사에 의한 화상에는 다소 차이가 있음을 확인하였다(Fig. 13 및 14). 초음파 현미경은 고체재료 또는 생물조직 상(10(12)등 여러 가지 생물연구 등의 응용이 계획되고 있으며, 특히 초음파 의학의 분야는 그 활용이 눈부실 것으로 예측된다. 초음파 현미경의 제작 그 자체보다, 이것을 도구로 하여 여러 가지 학술적, 기술적 성과가 기대되기 때문에 이 분야의 기초연구가 더욱 중요하게 생각되며 첨단산업분야에서도 비파괴검사 초음파 micro spectroscopy(U.M.S)등과 같은 물질의 탄성적 성질을 micro scale로 계측할 수 있는 등, 많은 활용이 있을 것이 예상된다. 또 초음파 현미경의 방법도 여러 가지이며, 이것을 계측수단으로 일반화하는 문제도 연구할 필요가 있다. 앞으로 광학이나 전자장치 등과 함께 급속한 발전이 기대된다.

  • PDF

주사 현미경용 평면 스캐너 Part 2 : 정 · 동 특성 평가 (A Flexure Guided Planar Scanner for Scanning Probe Microscope ; Part 2. Evaluation of Static and Dynamic Properties)

  • 이무연;권대갑;이동연
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1295-1302
    • /
    • 2005
  • This paper shows experimental evaluation results of the nano-positioning planar scanner used in the scanning probe microscope. The planar scanner is composed of flexure guides, piezoelectric actuators and feedback sensors as like explained in detail in Ref. (5). First, the fabrication methods were explained. Second, as the static Properties of the Planar scanner. we evaluated the maximum travel range & crosstalk. Also, we presented the correcting method for crosstalk using electric circuits finally. as the dynamic properties of the planar scanner, we evaluated the first resonant frequency. Also, we presented the actual AFM(atomic force microscope) imaging results with up to 2Hz imaging scan rate. Experimental results show that properties of the proposed planar scanner are well enough to be used in SPM applications like AFM.

Suppression of Melanose Caused by Diaporthe citri on Citrus Leaves Pretreated with Bio-sulfur

  • Shin, Yong Ho;Ko, Eun Ju;Kim, Su Jeong;Hyun, He Nam;Jeun, Yong Chull
    • The Plant Pathology Journal
    • /
    • 제35권5호
    • /
    • pp.417-424
    • /
    • 2019
  • Melanose, caused by Diaporthe citri, is one of severe diseases in citrus, a major economic resource in Jeju island. To reduce the usage amount of organic synthetic fungicide, bio-sulfur was tested as an alternative chemical to control citrus melanose in the present study. Direct antifungal activity of bio-sulfur against D. citri was determined through in vitro experiment using artificial nutrient media. Disease severity of melanose on bio-sulfur pretreated citrus leaves was lower than that on untreated ones. To illustrate the mechanism of disease suppression by bio-sulfur, infection structures were observed with a fluorescent microscope and a scanning electron microscope. In fluorescent microscopic observation, most conidia rarely germinated. In addition, hyphal growth on leaves pretreated with bio-sulfur was inhibited compared to that on untreated ones. In scanning electron microscope images of bio-sulfur pretreated leaves, surfaces of most conidia were shrunk while hyphae were morphologically changed and frequently branched. Such microscopic observations were also found for leaves pretreated with a commercial fungicide Dithianon. These results suggest that bio-sulfur may be used to control citrus melanose as an environment friendly alternative to organic synthetic fungicides

Confocal Scanning Laser Microscope (CSLM)을 이용한 피부 기저층 멜라닌 밀도의 정량화 (Quantification of Melanin Density at Epidermal Basal Layer by Using Confocal Scanning Laser Microscope (CSLM))

  • 김동현;이승호;오명진;최고운;양우철;박장서
    • 대한화장품학회지
    • /
    • 제40권3호
    • /
    • pp.259-268
    • /
    • 2014
  • 최근 여러 가지 비침습적인 방법으로 피부조직의 생검 또는 조직학적 처리과정 없이 피부의 실시간 이미지를 이용한 연구가 가능해졌다. Confocal scanning laser microscope (CSLM) 이미지는 830 nm의 근적외선 파장을 사용하는 비침습적 방법으로 피부의 내부 구조를 이미지화할 수 있으며, CSLM을 이용한 연구를 통해 비침습적인 피부 측정법으로 색소 침착 부위의 기저층과 진피 유두 사이에서 melanin cap, papillary ring과 같은 지표가 뚜렷하게 관찰된다고 보고되었다. 본 연구에서는 scanning probe image processor (SPIP)소프트웨어를 사용하여 CSLM 디지털 이미지 정량 분석을 처음 시도하였으며 본 연구결과는 정성적 피부조직 이미지 데이터를 정량화함으로써 향후 CSLM 활용범위를 높이게 될 것으로 기대하고 있다.

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

초고진공용 주사형 터널링 현미경의 제작 (Construction of UHV Scanning Tunneling Microscope)

  • 구자용;김달현;박해원;김구영;이세경
    • 비파괴검사학회지
    • /
    • 제14권3호
    • /
    • pp.157-171
    • /
    • 1994
  • 진공도가 $10^{-11}$ Torr 수준의 초고진공 상태에서 작동되고 실제공간에서 개별원자를 구별할 수 있는 주사형 터널링 현미경을 제작하였다. 주사형 터널링 현미경의 배경 및 작동원리와 제작에 있어서의 제문제점들을 서술하고 흑연결정과 실리콘에 대해서 관찰한 결과를 보고한다.

  • PDF