• 제목/요약/키워드: scan time

Search Result 1,259, Processing Time 0.035 seconds

A Study on the Change of Body Temperature according to the Needle Remaining Time at LU9 - Through the D.I.T.I. Scan - (태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-)

  • Lee, Bong-Hyo;Lee, Kyung-Min;Park, Ji-Ha;Kim, Min-Seo;Kim, San-Deul;Park, Byeong-Gyu;Yang, Hyun-Dong;Yea, Sung-Ho;Lee, Ho-Jung;Choi, Jae-Won;Hong, Hye-Lin;Lee, Eun-Jung;Lim, Sung-Chul;Kim, Jae-Su;Lee, Yun-Kyu;Lee, Hyun-Jong;Jung, Tae-Young;Jung, Hyun-Jung;Kam, Chul-Woo
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.188-199
    • /
    • 2012
  • Objectives : This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods : The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographic change was evaluated using paired t-test and post hoc Wilcoxon test. Results : The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions : The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Is Preventive Bilateral Surgery Needed in Case of Bilateral Bullae on HRCT at Unilateral Primary Spontaneous Pneumothorax (일차성 자연기흉의 고해상 CT에서 보이는 반대편 기포의 예방적 기포절제술이 필요한가?)

  • Han, Jong-Hee;Kang, Min-Woong;Yu, Jeong-Hwan;Kim, Yong-Ho;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.215-219
    • /
    • 2007
  • Background: Due to the advancement of video assisted thoracoscopic techniques, an operation for primary spontaneous pneumothorax is now considered a common procedure. However, whether a preventive operation is necessary when a contralateral bulla is found on High Resolution Computed Tomography (HRCT) at the time of the first primary spontaneous pneumothorax attack is still unknown. In this retrospective study, it was our intension to find whether contralateral bullae are related to the occurrence of pneumothorax. Material and Method: Between January 1999 and April 2006, 550 patients were admitted to the Chungnam University hospital with primary spontaneous pneumothorax, which was confirmed by the HRCT scans in 190 patents. In these 190 patients, 159 had not received a bilateral operation after their first primary spontaneous pneumothorax attack. In these 159 patients, the relationship between the presence of contralateral bullae and the occurrence of pneumothorax was measured. Result: In these 159 patients, 67 had contralateral bullae confirmed inform the HRCT scan, and 92 had no visible contralateral bullae, During the follow up period, 6 patients (8.9%) with contralateral bullae had an occurrence of contralateral pneumothorax, and 5 patients (5.4%) without contralateral bullae had an occurrence of contralateral pneumothorax. (p=0.529 [Fisher's exact test]) Conclusion: In patients with unilateral primary pneumothorax, an HRCT scan is a useful way of confirming contralateral pulmonary bullae. However, the presence of bullae is not a significant predictive sign of an occurrence of contralateral pneumothorax. Also, surgery for pneumothorax is not completely uncomplicated, and bilateral surgery is still doubtful. A further prospective study will be required to find the relationship between the bullae found on HRCT and the occurrence of pneumothorax.