• 제목/요약/키워드: sanitary conditions

검색결과 233건 처리시간 0.025초

염색폐수의 전해처리 특성 (Characteristics of Eleclrolytic Treatment of Dye Wastewater)

  • 전법주;윤용수
    • 환경위생공학
    • /
    • 제11권3호
    • /
    • pp.37-46
    • /
    • 1996
  • In this study, the effect of pH, Temp, dye concentration, distance of electrode, and the potential on the removal efficiency of dye-wastewater using electrochemical reaction were investigated. Optimum conditions for the electrochemical treatment of dye-wastewater were obtained that pH;7, 8V, electrode distance; 1cm and the reaction time for obtaining above 99% removal efficiency were 10 - 40min at each conditions, From this result, we can determine the instantaneous current efficiency and specific energy consumption, and we can provide the effective data for economical treatment of industrial dye-wastewater.

  • PDF

목포시의 거주환경의 만족도와 어메니티 의식의 관계 (Relations between Amenity Awareness and Satisfaction of Residential Environment in Mokpo City)

  • 한명호;오양기;주문기
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.43-52
    • /
    • 2009
  • The aim of this study is to find out the solutions for an improvement of residential environment through the relation between satisfaction of residential environment and amenity awareness of the local residents in Chonnam Mokpo city. For this purpose, it is conducted a questionnaire survey of 203 local residents on the attributes of residential environment. The satisfaction factors of residential environment consist of 8 types of factors such as housing structure, stability, green tract of an avenue, convenience, housing environment, sanitary conditions, waterside facilities, and familiarity. It is analyzed that there is a great difference of the satisfaction between new town dwellers and old town dwellers in three satisfaction factors of a housing structure, convenience, and housing environment. The attributes of amenity awareness consist of 6 types of factors such as fitness, comfort, intimacy, vitality, naturalness, and brilliance. The new town dwellers have a high satisfaction in fitness and vitality factors, and the old town dwellers have a high satisfaction in naturalness factors. Through the analysis to the importance on the satisfaction factors of residential environment related to amenity awareness, it is founded that intimacy factor have importance in order of stability, familiarity, green tract of an avenue and sanitary conditions. Naturalness factor have importance in order of stability, waterside facilities, familiarity and green tract of a avenue. Fitness factor have importance in order of housing structure and sanitary conditions. Comfort factor have importance in order of stability, housing environment and sanitary conditions. And vitality factor have importance in order of housing environment, convenience and green tract of an avenue. Therefore, it is needed that the development plan of residential environment take into consideration in accordance with the importance on the satisfaction of residential environment in Mokpo city.

서울, 경기지역 도시락 제조업체의 위생실태 및 도시락 생산의 품질개선을 위한 연구 (A Study for the Improvement of the Sanitary Condition and the Quality of Packaged Meals(Dosirak) Produced in Packaged Meal Manufacturing Establishments in Seoul city and Kyungki-do Province)

  • 계승희;윤석인;박희순;심우창;곽동경
    • 한국식품위생안전성학회지
    • /
    • 제3권3호
    • /
    • pp.117-129
    • /
    • 1988
  • 서울·경기지역 도시락 제조업체의 작업환경 및 도시락의 부식인 동태전 생산과정의 위생상태를 위생 점검표 및 미생물 검사를 토대로 분석, 평가한 결과는 다음과 같다. 1) 주방의 위생 상태는 향상 가능성이 있는 보통상태로 나타났고, 종업원의 위생습관은 대·중규모 업체는 향상가능성이 있는 보통상태이었으며 소규모 업체는 위험요인이 존재하는 불량상태로 나타났다. 2) 도시락 제조업체별로 동태전의 생산과정에서 원재료와 전처리 후의 재료는 미생물적인 품질이 낮았다. 3) 조사결과 조리한 음식을 실온에서 보관하는 단계와 출고하기 전까지 조합하고 포장하는 동안 실온에서 방치하는 단계는 온도 및 소요시간이 미생물 증식에 적합한 환경이 되는 위험한 단계이었다. 4) 각 업체에서 사용하는 칼, 도마 ,행주의 미생물 수치가 높아 cross contamination의 가능성이 높았다. 5) 도시락 제조업체에서 동태전의 생산 과정중의 critical control points 는 전처리단계 , 보관단계, 조합과 포장단계 및 기구로 지적되었다.

  • PDF

대구시내 미용실의 보건위생 실태 (Status of Health Hygiene of Some Beauty Shop in Taegu City)

  • 채용곤
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.9-20
    • /
    • 2001
  • The objective of this study was to improve sanitary conditions at the beauty shops by informing the owners and employees to be aware of the public health. The data were obtained by the Physical investigation (August 1 to 30, 2001) of the sanitary Problems at 112 beauty shops in Daegu Metrpolitan area and by the surveys from the employees and customers. By analysis these data with SAS/PC+(ver. 6.12) and $x^2-test$, we have obtained the following results. 1. The numbers of the beauty shop workers (67.86% of the shops) were two including the owner, and only 18.75% of the workers had the regular public health training session. Even at the training sessions, no public health specialist was available as an instructor. 2. Sanitary conditions of the floor (92.76%), washer (88.93%) and rest room (74.11%) at the beauty shops were satisfactory. However, only 3.57% of the beauty shop used the vacuum cleaner that would be far more effective than the bloom to remove hairs from the floor. 3. About 91.07% (102 shops) did not or poorly sterilize equipments, and 91.76% (103 shops) did not store the sterilized or non-sterilized equipments separately. The shops that had the ultraviolet sterilizer that is required by the public health regulation were 53.57% (60 shops), and only 2.67% (3shops) actually used it. 4. About 82.14% (72 shops) used Oxyclean and detergent for washing the fabrics such as towels and gowns. About 11.61% (13 shops) used only detergent and 3.57% (4 shops) used the boiling sterilization method. No shop used the customer gown once per customer, and only 2.68% (3 shops) washed the used gown daily.

  • PDF

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • 분석과학
    • /
    • 제36권2호
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

소화슬러지 탈수성 개선을 위한 폐달걀껍질 재활용 (Recycling of waste egg shells for dewaterability improvement in digested sludge with recycling of waste egg shells)

  • 김은호;김성수
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.38-46
    • /
    • 2001
  • The purposes of this study were to examine applicability of waste egg shells as conditioning agent, to determine the optimum conditions for improving digested sludge dewaterability and to compare with before and after adding them. It estimated that the optimum conditions were dosage 30 g/L, particle size 10mesh, temp. $30^{\circ}C$, pH 7 and dewatering pressure $2.66{\pm}10^4{\;}N/m^2$. On the basis of induced optimum conditions, if adding waste egg shells in digested sludge, its specific resistance was $1.13{\pm}10^{12}{\;}m/kg$ and was low about 3 times than raw digested sludge $3.5{\pm}10^{12}{\;}m/kg $. Therefore, in view of waste recycling, it seemed that we could utilize waste egg shells as conditioning assent for improving dewaterability of digested sludge.

  • PDF

광촉매 코팅농도가 포름알데히드 제거능에 미치는 효과 - 코팅 두께 표준화 연구를 중심으로 - (Effect of Removal Efficiency of Formaldehyde by Input Coating Concentration of Photocatalyst - with Study of Standardization of Coating Thickness -)

  • 박영규;한만소
    • 환경위생공학
    • /
    • 제20권4호통권58호
    • /
    • pp.51-58
    • /
    • 2005
  • Photocatalytic degradation using $TiO_2$ Particles suspended in a reactor was experimentally performed to degrade the formaldehyde of indoor pollutants. Exponential increase of degradation appears to prove light availability due to the scattering of W light by particles themselves. Comparative removal studies of formaldehyde were done in both cases of dipping and spraying immobilized techniques of $TiO_2$ Particles suspended in solution. Experiments were performed under several different experimental conditions such as initial concentration of formaldehyde, UV intensity and concentration of photocatalysts. Optimal conditions to degrade formaldehyde were obtained under the conditions of $30\;mg/cm^2$ concentration of catalyst and UV intensity of 30 Watt at the distance of 30 cm using immobilized technique by dipping coating.

한식 제공 음식업소의 위생 및 시설 조사 연구 (I) -작업환경 위생 및 조리설비 평가- (A study for the Improvement of Sanitary Condition in Korean style-restaurant in Seoul city area (I) - Evaluation on sanitation of working environment and facilities for the kitchen-)

  • 계승희;문현경;정해랑;황성희;김우선;문혜연
    • 한국식생활문화학회지
    • /
    • 제9권5호
    • /
    • pp.457-465
    • /
    • 1995
  • The purpose of the present study is to identify potentially hazardous factors which can contribute to the outbreak of foodborne disease and to represent more practical management methods in terms of environmental sanitation and facilities for the kitchen. 230 Korean-style restaurants in Seoul were assessed and analyzed by the restaurant total area. Facilities and sanitary check-lists were developed to evaluate the facilities and sanitary conditions of sampled restaurants. The sanitary condition of kitchen, guest room and other area were assessed by the sanitary score. The basic cooking machinery and utensil were properly facilitated but automation machinery were equiped below 10% sampled restaurants. The kitchen area were not properly sufficient to total area. Sanitary condition of kitchen, guest room, cooking appliance and stored foods were evaluated as the unsatisfactory state with potentially hazardous. Concrete guidelines should be made in terms of following item; establishment for the kitchen space expansion, facilities for the improvement of the working environment and sanitary condition of foods cooked. Additionaly, it need to practice the effective education and training program for the foodservice manager and employees.

  • PDF

농촌급수시설에 관한 환경위생확적 조사연구 (A Survey on the Envlronmcntal Sanitary Status of Water Supply System in Rural Area)

  • 박국환;김성자
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.76-85
    • /
    • 1978
  • This survey was undertaken for the period seven month beginning January 15, 1977 and ending July 31, 1977 to detect the general sanitary status of the villages and the villagers and, at the same time, analyse quality of water sources with emphasis on a total of 1,256 households dividing into three different groups: such as, 280 households were selected as random samples from the area of the sophisticated piped water supply system, 122 households from the area of the simplified water supply system and finally 854 households from the area of nonpi-ped water supply system. The following results were concluded after quality of water sources had been analysed and conditions of the environmental sanitation had been reviewed: 1. 11.2% of the respondents from the area of the sophisticated piped water supply system responded that quantity of drinking water lacked to meet their demand while 30.6% of the villagers from the area of nonpi-ped water supply system responded quantity of drinking water didn't meet their demand. 2. 30.8% of the.respondents from the area of the sophisticated water supply system responded that contaminating source located within 15 meters from the water source while 54.4% of the respondents from the non-piped water supply system claimed the same. 3. It was found that water from all sampling areas were positive in coliform group with exception of Moonsan which is one of the sophisticated piped water supply system groups and the number of general bacteria exceeded the government standard criteria of water quality in the area of the nonpi-ped water supply system. 4. In relation with time requirement to draw water in the area of non-piped water supply system, 76 respondents claimed it requires less than 15 minutes to draw water, 15.0% claimed 15 to 30 minutes and 9.0% claimed more than 30 minutes. 5. In relation with knowledge on sanitation of drinking water, 30.8% of respondents from the area of the sophisticated piped water supply system and 41.8% of respondents from the area of nonpiped water supply system denied possible existence of germ in drinking water they drink, while 17.4% of the respondents from the area of the sophisticated water supply system and 50.2% of non-peped water supply system thought it safe to drink water without any treatment. 6. 60.0% of the respondents from the area of non-piped water supply system and many of them believed that their health status will be improved by installation of a sophisticated water supply system in their area. 7. The respondents from the areas of piped water supply sytem expressed greater concern over drinking water sanitation than those from the areas of non-piped water supply system and sanitary conditions were found the same. It was, therefore, proved that knowledge of environmnntal sanitation contributed a great deal to improve sanitary conditions of the villages and villagers and at the same time health education, especially environmental sanitation, will be played a important role to improve their sanitary conditions.

  • PDF