• Title/Summary/Keyword: sandwich immunoassay

Search Result 45, Processing Time 0.023 seconds

Bioanalytical Application of SERS Immunoassay for Detection of Prostate-Specific Antigen

  • Yoon, Kyung-Jin;Seo, Hyeong-Kuyn;Hwang, Hoon;Pyo, Dong-Jin;Eom, In-Yong;Hahn, Jong-Hoon;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1215-1218
    • /
    • 2010
  • We demonstrate the possible application of the sandwich type surface-enhanced Raman scattering (SERS) immunoassay using antigen-antibody binding for detection of prostate-specific antigen (PSA) in cancer cells. In this sandwich type of SERS immunoassay, to capture antigens onto the immobilized layer of antibodies on the gold substrate we prepared the monolayer of gold nanoparticles on the APTMS-derivatized surface of a glass slide by using the SAM technique. This sandwich type of SERS immunoassay in which antigens on the substrate specifically capture antibodies on a Raman reporter (DSNB coated gold nanoparticles with R6G) could successfully detect PSA at low levels. A strong SERS spectrum of Raman reporter was observed only with a substrate in which PSA is present.

Application of Immunoassay for the Detection of Gamma-Irradiated Shrimp (감마선 조사된 새우의 검지를 위한 면역분석법의 적용)

  • 이주운;육홍선;조경환;차보숙;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.4
    • /
    • pp.600-604
    • /
    • 2001
  • Immunoassay was used to study the detection method of irradiated shrimp. Sandwich ELISA was formatted with monoclonal antibody (Ab) (M-IgG) and polyclonal Abs (P-IgG) and polyclonal Abs (P-IgG) individually produced against brown shrimp tropomyosin (TPM) as an antigen. When M-IgG was used as a coating Ab to capture TPM, and P-IgG were used as reaction Ab against captured TPM could be detected in the range of 12.5 to 50 $\mu\textrm{g}$/mL. Detected concentrations of TPM from irradiated shrimp decreased dose-dependently, and the concentration of Ag by combination of irradiation with heating or freezing treatments also decreased. This results suggests the possibility for Sandwich ELISA, one of immunological analyses, to be applied for detecting irradiated shrimp.

  • PDF

Development of an Open Sandwich Fluoroimmunoassay Based on FRET (FRET에 기반한 Open Sandwich Fluoroimmunoassay)

  • Wei, Quande;Lee, Moon-Kwon;Seong, Gi-Hun;Choo, Jae-Bum;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.426-432
    • /
    • 2007
  • We have developed a sensitive, one-step, homogeneous open sandwich fluoroimmunoassay (OsFIA) based on fluorescence resonance energy transfer (FRET) and luminescent semiconductor quantum dots (QDs). In this FRET assay, estrogen receptor-$\beta$ (ER-$\beta$) antigen was incubated with QD-labeled anti-ER-$\beta$ monoclonal antibody and AF (Alexa Fluoro)-labeled anti-ER polyclonal antibody for 30 minutes, followed by FRET measurement. The dye separation distance was estimated to be between $80\sim90\;{\AA}$. The present method is rapid, simple and highly sensitive, and did not require the bound/free reagent separation steps and solid-phase carriers. A concentration as low as 0.05 nM (2.65 ng/ml) receptor was detected with linearity ($R^2$ > 0.990). In addition, the assay was performed with commercial antibodies. This assay provides a convenient alternative to conventional, laborious sandwich immunoassays.

Development of a One-step Two-site Enzyme Immunoassay for Measuring Human Alpha-fetoprotein by Eliminating Hook-effect

  • Kim, Se-Ho
    • BMB Reports
    • /
    • v.34 no.1
    • /
    • pp.47-50
    • /
    • 2001
  • A one-step, two-site enzyme immunoassay was developed for measuring human alpha-fetoprotein (AFP) in serum and amniotic fluid using monoclonal antibodies (McAb) by eliminating the high-dose hook effect. Three McAbs that recognize different epitopes were selected among 16 different clones on the basis of epitope mapping, two for immobilization and one for horseradish peroxidase conjugation. This one-step immunoassay system is more convenient and rapid compared to a conventional two-step sandwich immunoassay system. It did not exhibit the hook effect to around 2.7 mg/ml of AFP, which is probably one of the highest concentrations of AFP in the serum. The dose-response curve of the system was linear to 500 mg/ml of AFP and the system could differentiate as low as 1 mg/ml of AFP The intra- and inter-assay variations were in an acceptable range; 95~104% and 97~105% respectively Its correlation with other commercial systems was around 95%.

  • PDF

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Detection of Peanuts in Commercially Processed Foods by an Enzyme-Linked Fluorescent Immunoassay (Enzyme-linked fluorescent immunoassay에 의한 가공식품 중 땅콩의 검출)

  • Kim, Mi-Hye;Kim, Hyun-Jung;Shon, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.111-115
    • /
    • 2009
  • In this study we analysed for peanuts in processed foods using an enzyme-linked fluorescent immunoassay (ELFA), and compared the results with labeled ingredients. Crude peanut protein (CPP) was immunized into rabbits to produce specific antibodies(Ab). A sandwich ELFA was established using anti-CPP Ab and Ab-horseradish peroxidase (HRP) conjugate. The cross-reactivities of the Ab toward CPP, peanuts, almonds, soybeans, and walnuts were 100, 9.8, $1.1{\times}10^{-2},\;4.4{\times}10^{-3}$, and 0%, respectively. The samples included 19 items consisting of biscuits, snacks, chocolates, and so on. The results from the sandwich ELFA showed that peanuts were contained in 7 of the processed food items, among which, 5 items were labeled as having peanuts present but 2 items were not. One of the 2 items that was peanut-detected but unlabeled was a biscuit labeled to contain almonds and assayed to contain $2.1{\times}10^{-3}%$ peanuts, which might have been due to the weak cross-reactivity of the Ab toward almonds. The other item was a snack labeled to contain soybeans and assayed to contain 0.098% peanuts, which might have been due to peanut cross-contamination during processing, since the crossreactivity of the Ab toward soybeans was very weak. These results suggest that ELFA is a good tool to detect peanuts in processed foods, and allergens in certain processed foods should be labeled correctly.

Norovirus Targeted Bioreceptor Screening Method based on Lateral Flow Immunoassay (LFIA) (노로바이러스 검출을 위한 측면유동면역분석법 기반의 바이오리셉터 선별기법 개발)

  • Huisoo, Jang;Hyeonji, Cho;Tae-Joon, Jeon;Sun Min, Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.136-145
    • /
    • 2022
  • Later flow immunoassay (LFIA) is a protein analytical method based on immunoreaction. On the LFIA based protein analytical method, bioreceptor molecule plays a key role, and so a system that evaluates and manages the binding affinity of bioreceptor is needed to secure detection reliability. In this study, Lateral Flow Immunoassay based rapid Bioreceptor Screening Method (rBSM) is presented that provide a simple and quick evaluating method for the binding affinity to the target protein of the antibody as model bioreceptor. To verify this evaluation method, Virus-like particles (VLP) and anti-VLP antibodies are selected as a model norovirus, which is target protein, and the candidate bioreceptors respectively. Among the 5 different candidate antibodies, appropriate antibody could be sorted out within 30 minutes through rBSM. In addition, selected antibodies were applied to two representative LFIA based techniques, sandwich assay and competitive assay. Among these methods, sandwich assay showed more effective VLP detection method. Through applying selected antibodies and techniques to the commercialized mass production lines, an VLP detecting LFIA kit was developed with a detection limit of 1012 copies/g of VLPs in real samples. Since this proposed method in this study could be easily transformable into other combinations with bioreceptors, it is expected that this technique would be applied to LFIA kit development system and bioreceptor quality management.

Protein Array Fabricated by Microcontact Printing for Miniaturized Immunoassay

  • Lee Woo-Chang;Lim Sang-Soo;Choi Bum-Kyoo;Choi Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1216-1221
    • /
    • 2006
  • A protein array was fabricated for a miniaturized immunoassay using microcontact printing ($\mu$CP). A polydimethylsiloxane (PDMS) stamp with a 5 $\mu$m$\times$5 /$\mu$m dimension was molded from a silicon master developed by photolithography. Under optimal fabrication conditions, including the baking, incubation, and exposure time, a silicon master was successfully fabricated with a definite aspect ratio. An antibody fragment was utilized as the ink for the $\mu$CP, and transferred to an Au substrate because of the Au-thiol (-SH) interaction. The immobilization and antibody-antigen interaction were investigated with fluorescence microscopy. When human serum albumin (HSA) was applied to the protein array fabricated with an antibody against HSA, the detection limit was 100 pg/ml of HSA when using a secondary antibody labeled with a fluorescence tag. The fabricated protein array maintained its activity for 14 days.

Development of a Sandwich Enzyme Immunoassay for Salmon Gonadotropin II. (연어 생식소자극호르몬 II의 Sandwich Enzyme Immunoassay법 개발)

  • KIM Dae-Jung;HAN Chang-Hee;AIDA Katsumi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.1
    • /
    • pp.55-59
    • /
    • 2000
  • A specific and sensitive sandwich enzyme-immunoassay (EIA) using Avidin-Biotin complex was developed for the measurement of GTH II levels in pituitary content and pituitary cell culture medium of the rainbow trout-(Oncorhpchus mykiss). Biotin-salmon GTH II rabbit IgG (sefondary antibody) wai purified by a protein A sepharose affinity chromatography column and that was biotinylated by using Biotin-N-hydroxysuccinimide ofter (BNHS). Non-biotin salmon GTH II rabbit IgG (first antibody) was obtained only through a protein A sepharose affinity chromatography column. The assay was performed by the so-called 'sandwich' method using a microtiter plate, A dose-response curve was obtained between $0.12 to 125 ng/ml$ of salmon GTH II. The displacement curves for pituitary extraction and pituitary cell culture medium of testosterone-treated rainbow trout were Parallel to the standard curie. The intra-assay and inter-assay coefficients of variation (CV) were $8.2{\%} (N=5) and 12.5{\%} (N=6)$, respectively, This assay system was used to measure the amount of GTH II that accumulated in the culture medium of dispersed pituitary cells in testosterone-treated immature rainbow trout, The accumulation was increased with the amount or salmon gonadotropin-releasing hormone. GTH II values determined by the present method were well correlated with those determined by radioimmunoassay. As a result, this assay system was found to be suitable for the measurement of GTH II for pituitary extraction and pituitary culture medium in many salmonid fishes.

  • PDF