• Title/Summary/Keyword: sampling time

Search Result 2,805, Processing Time 0.031 seconds

Time-Balanced Quota Sampling for Telephone Survey (전화조사를 위한 시간균형할당표본추출)

  • Huh, Myung-Hoe;Hwang, Jin-Mo
    • Survey Research
    • /
    • v.7 no.2
    • /
    • pp.39-52
    • /
    • 2006
  • Most of Korean survey institutions adopt quota sampling for telephone surveys based on region, gender and age-band. In weekdays, it is well blown that there exist substantial differences in day time in-house rate by individual's socio-demographic attributes. So, quota sampling may induce systematic respondent selection bias. To solve the problem, we propose "time-balanced quota sampling" in which interviewer's call time-band is added as an quota variable. Furthermore, we propose "time-balanced quasi-quota sampling" which is derived by partially relaxing evening time quotas in time-balanced quota sampling. We compare the conventional and the newly proposed quota sampling schemes by drawing Monte Carlo samples from the hypothetical population for which the Korea 2004 time use survey data is assumed.

  • PDF

An improved linear sampled-data output regulators (개선된 선형 샘플치 출력 조절기)

  • 정선태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1726-1729
    • /
    • 1997
  • In general, the solvability of linear robust output regulation problem are not preserved under time-sampling. Thus, it is found that the digital regulator implemented by itme-sampling of anlog output regulator designed based on the continuous-time linear system model is nothing but a 1st order approximation with respect to time-sampling. By the way, one can design an improved sampled-data regulator with respect to sampling time by utilizing the intrinsic structure of the system. In this paper, we study the system structures which it is possible to design an improved sampled-data regulator with respect to sampling time.

  • PDF

Perfect Reconstruction in Sub-Nyquist Nonuniform Sampling of Signals with Known upper Time-frequency Boundary (비 균일 표본화 신호의 완전 복구에 관한 연구)

  • 이희영;정현권
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.9-12
    • /
    • 2002
  • The problem of sub-Nyquist nonuniform sampling for the perfect reconstruction of signals with time-varying spectral contents is studied. The signals are assumed to have a known instantaneous bandwidth in time-frequency domain. As the function of time, the nonuniform sampling pattern of a given signal, that is, the instantaneous sampling frequency is determined by the observation of instantaneous bandwidth based on time-frequency analysis. The proposed sampling pattern guarantees the perfect reconstruction of nonuniform sampled signals under Nyquist-sampling rate in average.

  • PDF

A Sampling Inspection Plan with Human Error: Considering the Relationship between Visual Inspection Time and Human Error Rate

  • Lee, Yong-Hwa;Hong, Seung-Kweon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.645-650
    • /
    • 2011
  • Objective: The aim of this study is to design a sampling inspection plan with human error which is changing according to inspection time. Background: Typical sampling inspection plans have been established typically based on an assumption of the perfect inspection without human error. However, most of all inspection tasks include human errors in the process of inspection. Therefore, a sampling inspection plan should be designed with consideration of imperfect inspection. Method: A model for single sampling inspection plans were proposed for the cases that visual inspection error rate is changing according to inspection time. Additionally, a sampling inspection plan for an optimal inspection time was proposed. In order to show an applied example of the proposed model, an experiment for visual inspection task was performed and the inspection error rates were measured according to the inspection time. Results: Inspection error rates changed according to inspection time. The inspection error rate could be reflected on the single sampling inspection plans for attribute. In particular, inspection error rate in an optimal inspection time may be used for a reasonable single sampling plan in a practical view. Conclusion: Human error rate in inspection tasks should be reflected on typical single sampling inspection plans. A sampling inspection plan with consideration of human error requires more sampling number than a typical sampling plan with perfect inspection. Application: The result of this research may help to determine more practical sampling inspection plan rather than typical one.

Multirate LQG Control Based on the State Expansion (상태 공간 확장에 의한 멀티레이트 LQG 제어)

  • 이진우;오준호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.131-138
    • /
    • 1999
  • In discrete-time controlled system, sampling time is one of the critical parameters for control performance. It is useful to employ different sampling rates into the system considering the feasibility of measuring system or actuating system. The systems with the different sampling rates in their input and output channels are named multirate system. Even though the original continuous-time system is time-invariant, it is realized as time-varying state equation depending on multirate sampling mechanism. By means of the augmentation of the inputs and the outputs over one Period, the time-varying system equation can be constructed into the time-invariant equation. In this paper, an alternative time-invariant model is proposed, the design method and the stability of the LQG (Linear Quadratic Gaussian) control scheme for the realization are presented. The realization is flexible to construct to the sampling rate variations, the closed-loop system is shown to be asymptotically stable even in the inter-sampling intervals and it has smaller computation in on-line control loop than the previous time-invariant realizations.

  • PDF

Output regulation of nonlinear sampled-data systems (비선형 샘플치 시스템의 출력조절)

  • 정선태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.391-394
    • /
    • 1996
  • The effects of time-sampling on nonlinear output regulation problem is investigated. Output regulatedness is preserved under time sampling as in linear systems, however output regulatability is not robust with respect to time-sampling, and thus one needs to seek an approximate nonlinear sampled-data output regulator.

  • PDF

Performance Analysis of Multirate LQG Control (멀티레이트 LQG 제어 기법의 성능 비교 분석)

  • 이진우;오준호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.123-130
    • /
    • 1999
  • In discrete-time controlled system, sampling time is one of the critical parameters for control performance. It is useful to employ different sampling rates into the system considering the feasibility of measuring system or actuating system. The systems with the different sampling rates in their input and output channels are named multirate system. Even though the original continuous-time system is time-invariant, it is realized as time-varying state equation depending on multirate sampling mechanism. By means of the augmentation of the inputs and the outputs over one period, the time-varying system equation can be constructed into the time-invariant equation. The two multirate formulations have some trade-offs in the simplicity to construct the controller, the control performance. It is good issue to determine the suitable formulation in consideration of performance of them. In this paper, the two categories of multirate formulations will be compared in terms of the linear quadratic (LQ) cost function. The results are used to select the multirate formulation and the sampling rates suitable to the desired control performance.

  • PDF

Comparison of two sampling intervals and three sampling intervals VSI charts for monitoring both means and variances

  • Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.4
    • /
    • pp.997-1006
    • /
    • 2015
  • In industrial quality control, when engineers use VSI control procedure they should consider both required time to signal and switching behaviors together in the case of production process changed. Up to the present, many researchers have studied fixed sampling interval (FSI) chart and variable sampling interval (VSI) chart in the points of average number of samples to signal (ANSS) and average time to signal (ATS). However, ANSS and ATS do not provide any switching information between different sampling intervals of VSI schemes. In this study, performances of two sampling intervals VSI chart and three sampling intervals VSI chart are evaluated and compared. The numerical results show that ANSS and ATS values of two sampling intervals VSI chart and three sampling interval VSI chart are similar regardless the amount of shifts. However, the values of switching behaviors including ANSW are less efficient in three sampling intervals VSI charts than in two sampling intervals VSI chart.

Optimal equivalent-time sampling for periodic complex signals with digital down-conversion

  • Kyung-Won Kim;Heon-Kook Kwon;Myung-Don Kim
    • ETRI Journal
    • /
    • v.46 no.2
    • /
    • pp.238-249
    • /
    • 2024
  • Equivalent-time sampling can improve measurement or sensing systems because it enables a broader frequency band and higher delay resolution for periodic signals with lower sampling rates than a Nyquist receiver. Meanwhile, a digital down-conversion (DDC) technique can be implemented using a straightforward radio frequency (RF) circuit. It avoids timing skew and in-phase/quadrature gain imbalance instead of requiring a high-speed analog-to-digital converter to sample an intermediate frequency (IF) signal. Therefore, when equivalent-time sampling and DDC techniques are combined, a significant synergy can be achieved. This study provides a parameter design methodology for optimal equivalent-time sampling using DDC.

An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR (비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구)

  • Kim, Woo-Seok;Shon, Deok-Young;Park, Young-Moo;Yoo, Jae-Suk;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.