• Title/Summary/Keyword: salt pollution

Search Result 129, Processing Time 0.031 seconds

Waveform analysis of leakage current on silicon insulator for various environment condition variation (환경조건변화에 대한 실리콘애자의 누설전류 파형분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.2
    • /
    • pp.69-76
    • /
    • 2004
  • This paper presents the results of spectral analysis about waveforms and leakage current waveforms on contaminated silicon insulators under various environment conditions.(salt fog, clean fog, rain). The larger the leakage current during 200ms, the higher the power spectrum at 60Hz. If contaminated insulators suffers from high salt density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evaluate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into service interrupting flashover that degrade power quality.

  • PDF

Sodium Chloride Decomposing Method in Food Waste Compost using Triple Salt (삼중염을 이용한 음식물 쓰레기 퇴비의 염분(NaCl) 분해방법)

  • Kim, Nam-Chean;Jang, Byung-Man
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.86-94
    • /
    • 2004
  • The characteristics of food waste in our country is high contents of water and sodium chloride(NaCl). Average water contents of household garbage was 80.0%, and those of wastes of restaurants and of wholesale market of agricultural products was 76.9% and 90.0%, respectively. The NaCl contents were high in household garbage and restaurant's waste as 3.36% and 4.84%, respectively. The NaCl contents of food waste composts made by various techniques known upto now were under the level of 1% by fresh weight basis. But these techniques has some problem that is environment pollution from treated water and high equipment cost. The application to agricultural land of food waste compost that is not sufficiently removed NaCl was considered to be improper due to salt accumulation in soils and plant growth inhibition by salt stress. The purpose of this study is to decompose NaCl in food waste compost using triple salt and this method is differ from existing chemical method. Also, reaction of NaCl with triple salt produced KCl that is basic material of potassium fertilizer. The experiment results of growing lettuce produced difference between food waste compost and treated food waste compost with triple salt. The latter got more high sprouting ratio and a growth rate.

  • PDF

Current Management Status of Mercury Emissions from Coal Combustion Facilities: International Regulations, Sampling Methods, and Control Technologies

  • Lee, Sung-Jun;Pudasainee, Deepak;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.1-11
    • /
    • 2008
  • Mercury (Hg), which is mainly emitted from coal-fired power plants, remains one of the most toxic compounds to both humans and ecosystems. Hg pollution is not a local or regional issue, but a global issue. Hg compounds emitted from anthropogenic sources such as coal-fired power plants, incinerators, and boilers, can be transported over long distances. Since the last decade, many European countries, Canada, and especially the United States, have focused on technology to control Hg emissions. Korea has also recently showed an interest in managing Hg pollution from various combustion sources. Previous studies indicate that coal-fired power plants are one of the major sources of Hg in Korea. However, lack of Hg emission data and feasible emission controls have been major obstacles in Hg study. In order to achieve effective Hg control, understanding the characteristics of current Hg sampling methods and control technologies is essential. There is no one proven technology that fits all Hg emission sources, because Hg emission and control efficiency depend on fuel type, configuration of air pollution control devices, flue gas composition, among others. Therefore, a broad knowledge of Hg sampling and control technologies is necessary to select the most suitable method for each Hg-emitting source. In this paper, various Hg sampling methods, including wet chemistry, dry sorbents trap, field, and laboratory demonstrated control technologies, and international regulations, are introduced, with a focus on coal-fired power plants.

A Analysis on the Accumulation Characteristics of Salt Contaminants for Outdoor Insulators with Statistical Treatment (통계 처리기법을 활용한 옥외 절연물의 염해 오손물 누적특성 분석)

  • Choe, Nam-Ho;Park, Gang-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.39-45
    • /
    • 2002
  • To determine the representative pollution degree of outdoor insulators during the drought season, we should make an investigation on the long-term accumulation characteristics of contaminants. As the contamination mechanism of outdoor insulator is extremely depend on the climatic condition, there is a large difference between the research result of Japanese utilities. So based on the difference of precipitation of the Korea and Japan, we could say that the accumulation characteristics of the countries have a significant difference. But, based on the result of Japan, the accumulation property of contaminants was ignored in KEPCO\`s specification. So, to determine the accumulation characteristics of Korea, we measured the 2 and 3 month ESDD with brush wiping method and make a statistical analysis on measured data. And, from the results, we understood the accumulation characteristics of Korea and the influence of topographical condition on the distribution characteristics of salt contaminants. coast.

The Electrical Properties of Non-Uniformly Contaminated Insulator (국부오손에 의한 절연물의 전기적 특성)

  • Choi, Nam-Ho;Park, Kang-Sik;Koo, Kyung-Wan;Kim, Jong-Serk;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.935-938
    • /
    • 2002
  • The degree of contamination in outdoor insulation system is one of the most importance factor to determine the level of insulation, and the salt is known as the most dangerous contaminants in the most region of the world. In a macroscopic point of view, as shown through the preceding study, the generation and deposition of salt contaminants has a great relation with the geographical conditions and the meteorological conditions, such as, wind velocity, wind direction, precipitation and so forth. However, in the aspect of microscopic analysis, the pollution mechanism has a great relation with aerodynamic properties of insulator, originated from the profile of insulators, and the non-uniform deposition is unevitable. So, in this investigation, we had make a experiment to seize the electrical properties of non-uniformly contaminated insulator. The results of this investigation could be used as a good groundwork in the determination of outdoor insulation design.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

An Experimental Basic Study of Water Purification Function due to Spit in Small Estuary (하구에 형성된 소규모 모래톱의 수질정화 기능에 관한 기초적 연구)

  • Park, Sang-Kil;Kim, Byung-Dal;Jeong, Seong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.8-15
    • /
    • 2007
  • This study is intended to examine the relationship between the magnitude of sand spit in the estuary of the stream and improvement of the quality of water that flaws into the sea, by means of hydraulic experimentation. In order to determine the effect of improvements of water quality when river flow is stagnant, the estuary flows into the sea through the small sand spit, and a two-dimensional physical model experiment was carried out. Distribution of concentration was decreased in response to an increase in length of sand spit and time. The experimental results are compared with theoretical results, based on the solution of the equation. Also, there are functions of influx prevention of salt wedge and purification of pollution water due to sand spit in small estuary.

Isolation and Sequence Analysis of Ycf4 Gene from Zoysia japonica Steud.

  • Kim, Yang Ji;Lee, Hyo Yeon;Hyun, Hwa Ja
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.100-100
    • /
    • 2018
  • Zoysia japonica Steud.(Zj) is a typical warm-season Korean lawn grass, which is used in many places such as river banks, roadside and soccer fields in Korea. Recently, it has also been used in school yards and the Saemangeum reclaimed land to reduce water pollution. Although the cultivated area of turfgrass is steadily increasing worldwide, it grows fast requiring frequent mowing and is difficult to grow in shady areas and the cold region. Therefore this study aims searching for useful gene(s) to develop abiotic stress tolerant and dwarf zoysiagrass. We isolated Ycf4 gene based on the sequence from Oryza sativa Japonica through RT-PCR and RACE PCR. Ultimately, open reading frame (ORF) of ZjYcf4 was 558bp long, encoding a protein of 186 amino acid residues. NCBI blast results showed that the ZjYcf4 protein is evolutionarily closely related to Ycf4 protein from Zoysia macrantha and Setaria italica (100% and 98%, respectively). To determine whether ZjYcf4 was involved in environmental stress in wild-type zoysiagrass, expression patterns of the gene were analyzed by real-time PCR under salt, cold and dark conditions. They were analyzed after each stress treatment for 3 hours. In salt and cold stresses, the expression was higher compared to control (3-fold and 1.5-fold, respectively), although there was a 1.6-fold decrease in expression under dark stress treatment. As reported previously, we suggest that ZjYcf4 gene affects abiotic stress such as salt, cold and dark.

  • PDF

Degradation of Phytate Pentamagnesium Salt by Bacillus sp. T4 Phytase as a Potential Eco-friendly Feed Additive

  • Park, In-Kyung;Lee, Jae-Koo;Cho, Jaie-Soon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.10
    • /
    • pp.1466-1472
    • /
    • 2012
  • A bacterial isolate derived from soil samples near a cattle farm was found to display extracellular phytase activity. Based on 16S rRNA sequence analysis, the strain was named Bacillus sp. T4. The optimum temperature for the phytase activity toward magnesium phytate (Mg-$InsP_6$) was $40^{\circ}C$ without 5 mM $Ca^{2+}$ and $50^{\circ}C$ with 5 mM $Ca^{2+}$. T4 phytase had a characteristic bi-hump two pH optima of 6.0 to 6.5 and 7.4 for Mg-$InsP_6$. The enzyme showed higher specificity for Mg-$InsP_6$ than sodium phytate (Na-$InsP_6$). Its activity was fairly inhibited by EDTA, $Cu^{2+}$, $Mn^{2+}$, $Co^{2+}$, $Ba^{2+}$ and $Zn^{2+}$. T4 phytase may have great potential for use as an eco-friendly feed additive to enhance the nutritive quality of phytate and reduce phosphorus pollution.

A research on the tunnel insulator pollution characteristic in Korea Railroad (철도 터널구간 애자류 오염도 분석에 관한 연구)

  • Jeon, Yong-Joo;Lee, Tea-Hoon;Choi, Kyoung-Il;Lee, Shi-Bin;Han, Sang-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1169_1170
    • /
    • 2009
  • This paper introduces insulator pollutant accumulate pattern in the tunnel of korea railroad. To accomplish this goal, effective sample collecting method was proposed for the first step. Dust at the surface was collected directly. Distilled water and brush was used while collecting. Through this method dust is easily and accurately collected. The second step is pollutant analysis. Several analyze item is selected such as quantity, conductivity, contact angle, Optical Microscope(OM), IR, Equivalent Salt Deposit Density(ESDD), and ICP-AES. The third step, best represent tunnel was selected considering location, length and natural surroundings. Also to consider the difference at inside the tunnel, several bracket insulators were selected along to the location. To make the result precise, above procedure was repeated several times at the same target. Finally relation among type of train, numbers of movement, surroundings, length will be considered in combination with the pollution. With this result pollute map for KORAIL could be accomplished and inspect period will be optimized case by case.

  • PDF