• Title/Summary/Keyword: roofing

Search Result 103, Processing Time 0.026 seconds

A Study on the Change to the Elevation and Roof of the Standard Rural-House Design After 1990's (1990년 이후 농촌주택 표준설계도의 입면과 지붕 변화에 관한 연구)

  • Hwang, Yong-Woon
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.23-30
    • /
    • 2010
  • The purpose of this study is to analyze the elevations of standard rural house designs after the 1990's. Various types of analysis were carried out on a total of 18 different sizes and 50 types of designs with p'yong sizes ranging from 12 to 44. The objects of analysis are the various elevations & the roof types that were supplied in the standard rural house design according to each year 1995 (8 sizes 20 types), 1997 (8 sizes 8 types), 1998 (l size 8 types), 2000 (2 sizes 4 types), 2001 (2 sizes 4 types), and 2004 (3 sizes 6 types). Results from the analysis demonstrate that (1) The gable roof has been used as the roofing type for standard rural house design since 1990. However the roof types of the standard rural house design includes only a few different types of gable roofs and roof materials(most roof types use asphalt shingle). (2) While most front elevations have been altered from asymmetrical to symmetrical most rear elevations have evolved from symmetrical to asymmetrical proportions since the 1990's (3) While siding materials and red-brick were most commonly used the main outer-wall materials prior to 2000, environmentally-friendly materials have been used as outer-wall materials since 2000. (4) In terms of the analysis of outer-wall objects before 2000 the walls were even, yet after 2000 these outer-walls evolved to become concave-convex walls. In other words, the evolution of the outer-wall has included a variety of wall types.

Basic Test on the Mechanical Characteristics of Polyester Membrane (폴리에스터 막재의 역학적 특성에 관한 기초시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Lee, Jang-Bok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of architectural membrane have fire proofing, lack of strength, tear resistance, durability and elasticity. For the estimation of this problems, it will be tested the basic mechanical properties of membrane material about tensile strength, tearing resistance and repeated loading behavior. Elastic modulus is 337.30~1257.63N/$mm^2$, and strain is 17.90~26.91%.

  • PDF

Questions and Solutions on Repair of Lime-Soil Consolidation in Traditional Buildings (전통 건축물 석회다짐층 보수 시공시의 문제점 및 개선 방안)

  • Kim, Jin-Man;Kwak, Eun-Gu;Suh, Man-Cheol;Cho, Heon-Young
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2002.02a
    • /
    • pp.21-31
    • /
    • 2002
  • Lime-soil consolidations are very important as structural material, bonding material, waterproofing material, and finishing material in korea traditional buildings. In this study, we investigated site application trouble in korea traditional buildings being repaired or restored, and propose following solutions. 1) To diminish quality variation occurred by slaking quick-lime in site, it is desirable to use slaked-lime for lime-soil consolidation. 2) For uniform construction of lime-soil consolidation, we would recommend builders to use mixer to be uniform mixture, premixed type materials and compacting machine in field, 3) and to use rigid suitable temporary construction as scaffold for preventing traditional buildings from additional damage occurred in demolition and construction of a layer of lime-soil consolidation of a roofing. 4) For suitable repair of traditional buildings, it is necessary to specify definitely materials and construction methods suggested by the standard specifications for repair of the cultural property.

  • PDF

A Farm on Broiler Chickens' Welfare in Korea (동물복지 관련 육계농가 실태조사)

  • Cheon, Si-Nae;Lee, Jun-Yeob;Choi, Yang-Ho;Park, Kyu-Hyun;Kim, Doo-Hwan;Song, Jun-Ik;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • We conducted investigations of the information and welfare of broiler chickens in Korea. The livestock housing of all broiler chicken farms were windowless type, bell feeder and nipple waterer were used, and stocking density was relatively higher (ranging from 18.2 $birds/m^2$ to 24.2 $birds/m^2$) than RSPCA's welfare standards for chicken hens (less than 19 $birds/m^2$). The ratios of sandwich panel, urethane form, slate, and steel plate in roofing materials were 61%, 21%, 13%, and 5%, respectively. The ratios of sandwich panel, urethane form, brick, and steel plate in wall materials were 61%, 21%, 13%, and 5%, respectively. The ratios of soil and concrete in flooring materials were 10% and 90%. The mist spray, fan, and cooling pad in cooling facilities were 42%, 32%, and 26%, respectively. Thus we believe that present data contribute to develop the animal welfare certification for broiler chickens and to improve animal welfare in Korea.

A Study on the Distribution Maps for Asbestos Cement Slates Using GIS (GIS를 이용한 석면슬레이트 분포지도 작성)

  • Kim, Young-Chan;Son, Byeung-Hun;Kim, Hye-Mi;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.57-62
    • /
    • 2011
  • Asbestos have been used around the world because of reliable and cost-effective physicochemical characteristics. After incubation period about 15-40 years asbestos can cause various cancers, including malignant mesothelioma when inhaled into the air. These properties turned out, asbestos have been banned from using in developed countries. Also in Korea also, the use of asbestos was banned across the board by revision of Industry Safety and Health Act in February 2009. Therefore, the problem of asbestos is not when using. It is about dismantling, maintenance, and the final processing of asbestos waste. Asbestos Cement slates which is Widely distributed throughout the country as roofing materials has much scattering potential compare with inside materials. Also Ministry of Environment is planning to introduce legislation 'Asbestos Safety Management Act' through Environment Announcement and The same Act. 24 show as follows. Minister of Environment or governor should do survey on the actual condition targeting rural buildings with slates and partly or fully fund to dissolve, remove asbestos slate which was used in each buildings. Therefore, to solve these problems, database-building and necessity of management strategies have been continually arisen. So this study was performed. Its application value is very high in terms of its political, economic. Asbestos Cement Slates database could build to collect national registered building data and then using GIS, asbestos cement Slates distribution map were constructed in each province's cities and counties of the country. And this map by Application, construction was to visualize by application, construction of year. Through these results, information of Asbestos Cement Slates could visually inform to policy makers, asbestos dismantling and management contractor, and civilian and it would alleviate the gap of knowledge information. This is expected to be utilized by medium and long-term and effective plan for demolition and dismantling of asbestos cement Slates.

A Study of the Physical Properties of Sungnyemun Tile (숭례문 기와의 물리적 특성 연구)

  • Chung, Kwang-Yong
    • Journal of architectural history
    • /
    • v.20 no.1
    • /
    • pp.23-39
    • /
    • 2011
  • The Sungnyemun roofing tiles were twice disassembled for maintenance work, in 1963 and 1997, and modern tiles were applied in 1997. However, besides differing in visual appearance, the modern tiles had distinctly different physical properties. A study has been carried out on 22 different tiles, including original Sungnyemun tiles, modern tiles applied during maintenance, traditional tiles made by tile-makers, and others, to examine their physical properties, such as bending strength, frost resistance, absorption, whole-rock magnetic susceptibility, chromaticity, differential thermal analysis, and other characteristics. Since the method of making modern tiles involves compressing clay in a vacuum, modern tiles showed relatively greater bending strength and specific gravity, while Sungnyemun tiles and those made by tile-makers, in comparison, demonstrated less bending strength and specific gravity owing to their production method of 'treading,' in which clay is mixed by having someone tread upon it repeatedly. Over time, the absorption rate of the original tile used for Sungyemun gradually decreased from 21% to 14.7%; traditional tiles from tile-makers showed absorption rates of 17%, while the absorption rate of modern tiles was just 1%, which is significantly low. As for frost resistance, Sungnyemun tiles and traditional tiles from tile-makers showed cracking and exfoliation after being subjected to testing 4 or 5 times, while slight cracking was seen on the surface for modern tiles after 1ngy, or 3 times. In other words, no significant difference from influence by frost was found. According to the results of differential thermal analysis, the plastic temperature was shown to have been no less than 1, $on^{\circ}C$ for all types of tile, and cristobalite was measuredthrough XRD analysis from a Sungnyemun female tile applied during maintenance in 1963, which appeared to have been plasticized at between $1,200^{\circ}C{\sim}1,300^{\circ}C$. Based on these research results on the physical properties of tiles from the Sungnyemun roof, a fundamental production method for tiles to be applied in the restoration of Sungnyemun has been identified.

Selection of the Best Oxygen Carrier for Chemical Looping Combustion in a Bubbling Fluidized Bed Reactor (기포유동층에서 케미컬루핑 연소시스템을 위한 최적 산소전달입자 선정)

  • Kim, Hana;Kim, Jung-Hwan;Yoon, Joo-Young;Lee, Doyeon;Baek, Jeom-In;Ryu, Ho-Jung
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.63-69
    • /
    • 2018
  • The reduction reaction characteristics and physicochemical properties were studied for the selection of oxygen carrier, which is the core of the chemical looping combustion (CLC) technology. Fuel conversion and $CO_2$ selectivity of oxygen carrier according to the concentration of reducing gas and the reduction temperature using three kinds of oxygen carrier (SDN70, N018-R2, N016-R4) were measured and compared. In addition, Attrition Index (AI) and BET surface area were measured to analyze the attrition resistance and the surface characteristics of the oxygen carrier. As a result, it was confirmed that all three kinds of oxygen carrier were suitable for use in chemical roofing combustion system, and the best particle was determined to be N016-R4.

Study of Characteristics of Clay Roof Tiles Using Ferro Nickle Slag Recycled Resources (페로니켈슬래그 순환자원을 활용한 점토기와의 성능평가)

  • Kim, Soon-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.281-291
    • /
    • 2021
  • To reduce the environmental load of the construction industry, there is a need to minimize construction and demolition by strengthening the eco-friendliness of building materials and extending the durable lifespan. Therefore, while many Hanok roof finishing methods have been proposed to address these problems, the current trend is to use the existing method due to issues such as economic feasibility, weight, and durability. The manufacturing method of clay roof tiles used as roofing materials for Hanok buildings is optimized by using a mixture of 64.5% Gyeongju clay, 15.0% kaolin, 15.0% FNS(Ferro Nickel Slag), and 5.5% MAS(Magnesia Aluminum Silicate) under optimal conditions. The results of the experiment involving firing at 1,125℃ showed that flexural strength of 12,102N, which is higher than the standard of KS F 3510, an absorption rate of 6.08%, a volume specific gravity of 2.15g/cm3, and the freeze-thaw properties were satisfied. A method for securing stable quality was studied.

Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

A Study on the Change and Factors of Landscape Facilities Shown in a Landscape Architecture Magazine (조경전문잡지를 통해 본 조경시설물의 변화 및 요인 연구)

  • Yu, Joo-Eun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.111-120
    • /
    • 2015
  • In this study, the general structure of the landscape architecture industry was considered through analysis of advertisements in the landscape architecture magazine, 'Environment & Landscape Architecture', and the transition process and factors of landscape facilities were analyzed. Based on this result, the direction of future landscape facilities and basic data were suggested. When analyzing the advertisements that have been published in 'Environment & Landscape Architecture' for 30 years, outdoor facilities were depicted at a frequency of 1,853 times and among them, rest facilities and convenience facilities were depicted 1,457 times and 378 times, respectively. The reason why outdoor facilities have a far higher advertisement frequency than other landscape facilities is they were highly influenced by the house construction-related government policy, which resulted from the expansion of the rest facility industry along with regional expansion to public design. Moreover, it was found that wood and steel were mainly used to make pergolas and benches, which are rest facilities, and polycarbonate, with high economic efficiency and durability, was used the most as a roofing material for pergolas. This study attempts to explore the tendency of landscape facilities and the changes in the detail of their types by analyzing the stream of landscape facilities diachronically, based on the advertisements published in a representative magazine of landscape architecture.