Studies on The Elution Behavior of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone Imine Chelates in Reversed-Phase Liquid Chromatography

  • Lee, Won;Kim, In-Whan;Kim, Mi-Kyoung;Kim, Yong-Jun;Jung, Hae-Rim;No, Kyoung-Tai;Kim, Su-Yeon
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.519-527
    • /
    • 1995
  • The retention mechanism of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone imine chelates in reversed-phase HPLC has been studied by examining the effect of temperature, mobile phase composition in acetonitrile-water mixture, and molecular structure on retention. The empirical retention equation was investigated to evaluate the properties of S (hydrophilic index). The value of the S index of the Ni(II) chelates decrease with the increasing column temperature and a linear relationship between S and log $k{_w}^{\prime}$ has been found. The results showed that the S index is influenced by the interaction between Ni(II) chelates and mobile phase. Molecular properties, van der Waals molar volume, polarizability and dipole moment, of the Ni(II) chelates were calculated by Cerius 2 program and the calculations were performed at Universal Force Field (UFF) model. The S value and log $k{_w}^{\prime}$ increase with decreasing the dipole moment of Ni(II) chelates.

  • PDF

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

Separation and Purification of Lipase Inhibitory Peptide from Fermented Milk by Lactobacillus plantarum Q180

  • Kim, Seulki;Lim, Sang-Dong
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.87-95
    • /
    • 2020
  • In this study, we separated and purified lipase inhibitory peptide from fermented milk by Lactobacillus plantarum Q180 with the aim of developing a new functional anti-lipase activity yogurt product. L. plantarum 180 was inoculated into 10% reconstituted skimmed milk and incubated at 37℃ until the pH of the culture reached pH 4.4. The lipase activity was measured using porcine pancreatic lipase. The lipase inhibitory peptides were gradually isolated by ultrafiltration, reversed phase column chromatography (RPC), reversed phase high-performance liquid chromatography (RP-HPLC), and gel permeation high-performance liquid chromatography (GP-HPLC) from the fermented milk by L. plantarum Q180. An ODS-AQ column was used for the RPC, a Vydac C18 column for the RP-HPLC, and a Superdex Peptide HR column for the GP-HPLC. The peptide was composed of Asp, Thr, Ile, Ser, Ala, and Gln, and the anti-lipase activity (IC50) was 2,817 ㎍/mL.

Development of simultaneous determination of vitamin A and E in infant formula by micro-HPLC (Micro-HPLC를 이용한 조제분유 중 비타민 A.E 동시분석법 개발)

  • Yun I-Ran;Choi You-Jeong;Lee Min-Kwon;Jeong Myeong-Ho;Kim Byeong-Hun
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.339-346
    • /
    • 2006
  • Semi-micro-HPLC using a column-switching technique was developed for simultaneous determination of vitamin A and E contents in infant formula. Vitamin A and E were extracted by PDA - HPLC with reversed phase column using organic solvent and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with hydrolysis method and rapid extraction. Developed method has many advantages of simple and rapid sample preparation and simultaneous determination of vitamin A and E by micro-HPLC using reversed phase column.

A Modified Selective Ground Relay for Ungrounded Distribution Systems

  • Nam Soon-Ryul;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • Selective ground relays (SGRs) are useful fur distinguishing a faulted feeder from the sound feeders in ungrounded systems. However, they sometimes mis-operate due to human or device errors. Particularly, the reversed polarity of zero-sequence current transducers (ZCTs) is the most frequent cause of mis-operation. This paper presents a modified SGR for reducing the probability of mis-operations caused by the reversed polarity of ZCTs. The modification is achieved by introducing an adaptive time delay, which depends on the magnitude of the zero-sequence current and the phase angle deviation from the reference. The modified SGR was successfully demonstrated on a sample ungrounded system without mis-operation.

Separation of Inorganic Anions by Reversed-phase Ion Chromatography (역상 이온 크로마토그래피에서 무기음이온의 분리)

  • Kih Soo Joe;Tae Yoon Eom;Seung Soo Kim;Youn Doo Kim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.452-457
    • /
    • 1988
  • Capacity factors (k') of some inorganic anions including $BF_4^{-1}$ were measured on cetylpyridinium coated column, and with dynamic system using tetrabutylammonium salicylate on PRP-1 reversed-phase column, respectively. After optimum separation condition was obtained this method was applied to the determination of boron in some different type samples.

  • PDF

DETERMINATION OF PURINE AND PYRIMIDINE BASES IN RUMEN MICRO-ORGANISMS BY REVERSED PHASE HPLC AFTER HYDROLYTIC DIGESTION UNDER PRESSURE

  • Han, Y.K.;Landis, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.2
    • /
    • pp.161-164
    • /
    • 1991
  • A rapid and accurate method is described for the determination of nucleo-bases in rumen micro-organisms. A procedure to satisfactorily hydrolyse the micro-organisms involving reaction with a mixture of readily volatile organic acids (acetic and formic acids) under high pressure, is proposed, and optimal conditions for an analytical procedure with reversed phase HPLC is described. The following nucleobases contents (mmol/kg DM) of rumen micro-organisms were found: Adenine (Ade), 82.62; Guanine (Gua), 61.34; Cytosine (Cyt), 84.61; Thymine (Thy), 35.74; Uracil (Ura), 68.62; Hypoxanthine (Hxn), 13.06; Xanthine (Xn), 8.35. Total purine-N content (g/kg N) of rumen micro-organisms were 99.60. The nucleic acid N content (g/kg N) of microbial isolates were: RNA-N, 109.9; DNA-N, 50.9.

Enantioseparation of Neutral Compounds on a Quinine Carbamate-Immobilized Zirconia in Reversed-Phase Capillary Electrochromatography

  • Lee, Mun-Rak;Gwon, Ju-Rim;Park, Jung-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.82-86
    • /
    • 2010
  • Quinine (QN) is a weak anion-exchange type chiral selector and QN-based silica stationary phases have been widely used for enantioseparation of acidic chiral analytes in HPLC and recently in CEC. In this work we report enantioseparation of non-acidic chiral analytes on a quinine carbamate-immobilized zirconia (QNZ) in reversed-phase (RP) CEC. Influences of pH, composition of the buffer, acetonitrile content and the applied voltage on enantioseparation were examined. Enantiomers of the analytes investigated are well separated in acetonitrile/phosphate buffer mobile phases. Separation data on QNZ were compared to those on QN-bonded silica (QNS). Retention was longer but better enantioselectivity and resolution were obtained on QNZ than QNS.

The Pharmacokinetic Study of Josamycin in Flounder by Reversed Phase High Performance Liquid Chromatography (고성능 역상 액체 크로마토그래피를 이용한 넙치에서의 Josamycin의 약물동태에 관한 연구)

  • 오수연;장원철
    • Toxicological Research
    • /
    • v.14 no.4
    • /
    • pp.563-567
    • /
    • 1998
  • This study was conducted to observe the distribution of josamycin, a macrolide antibiotic in flounder. Josamycin was administered orally to the flounder at the dose of 100 mg 1 kg josamycin in flounder. Josamycin in blood and various organs of flounder was analyzed using reversed phase HPLC. In blood kinetics study, Cmax was shown 9.50 $\mu\textrm{g}$/$m\ell$ at 45 min. after treatment and then decreased slowly up to 8th day. Concentration of josamycin in muscle was 0.47$\mu\textrm{g}$/g tissue at 11th day of the treatment and 0.41$\mu\textrm{g}$/g tissue at 7th day for liver. The concentration of josamycin in all the tested organs except gall bladder was decreased as the time passed. On the contrary, josamycin in gall bladder was increased 3.8 times at the day of 5th compared to that of the 1st day aftreatment.

  • PDF

Quantitative determination of pseudoephedrine in human plasma by reversed-phase liquid chromatography-electrospray ionization mass spectrometry

  • Kim, Jin-Ki;Cho, Jung-Hye;Woo, Jong-Soo;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.394.2-394.2
    • /
    • 2002
  • A sensitive and selective reversed-phase LC-ESI-MS method to quantitate pseudoephedrine in human plasma was developed and validated. Phenacetin was used as an internal standard. Samples were prepared simply by acetonitrile precipitation without an evaporation step. Chromatographic separation was achieved on a XTerra MS C18 column ($150{times}2.1$ mm I.D.. 3.5 $\mu\textrm{m}$ particles). using gradient elution with 0.5% (v/v) trifluoroacetic acid (TFA) in water and 0.5% (v/v) TFA in methanol at a flow-rate of 0.1 ml/min. (omitted)

  • PDF