• Title/Summary/Keyword: relay feedback

Search Result 73, Processing Time 0.03 seconds

Implementation of Optical Magnetic Field Sensor for Measurement of Over Current (과전류 계측을 위한 광자계센서의 구현)

  • Park, Hae-Soo;Roh, Jong-Dae;Kim, Yo-Hee;Park, Byung-Seok;Ahn, Seong-Joon;Jo, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

Auto-tuning of boiler drum level controller in Thermal Power Plant (화력 발전소 보일러 드럼수위 제어기의 자동 동조)

  • Lee, J.H.;Joo, H.Y.;Byun, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2584-2586
    • /
    • 2000
  • A drum level control is one of the most important control systems in thermal power plant. The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant set-point regardless of disturbance such as main steam flow. The implemented drum level controller is the cascade PI controller. The important factor in drum level controller is the parameters of two PI controllers. The tuning of PI controller parameter is tedious and time-consuming job. In this paper, the relay feedback Ziegler - Nichols tuning method extended to auto-tune cascade PI drum level controller. Finally, the simulation result using boiler model in Power Plant shows the validity of auto-tuned cascade PI controller.

  • PDF

Analysis of nonlinear control systems with various diher signals (비선형제어계에 사용하는 제선형화신호의 해석)

  • 이상혁
    • 전기의세계
    • /
    • v.13 no.2
    • /
    • pp.5-10
    • /
    • 1964
  • Some nonlinearities in feedback control systems, such as relay servo, Coulomb friction, saturating amplifier of backlash in gears cause some undesirable effects. These may be static errors, limit cycles or jump phenomena. So, linearizing method of these nonlinearities using dither signals was first suggested by Loeb. He pointed out that the addition of high frequency signal to either the input or the output of a nonlinear system would make the nonlinear performance approximate the performance of linear systems. He used high-frequency sinusoidal wave as dither signal. But, in this thesis, general method of analysis is suggested for nonlinear control systmes using various dither signals, such as noise signal of Gaussian amplitude distribution, sinusoidal dither signal and sawtooth dither signal. Also, the advantage and disadvantage of these dither signals are compared. Throughout the analysis statistical method is adopted and lastly analog computer is used for the experiment of various nonlinear systems using dither signals.

  • PDF

Implementation of Wind Power System and Development of a Automatic Tail Safety Controller (풍력발전시스템의 강풍제어기 개발 및 시스템 구성)

  • Choi, Jung-Hoon;Moon, Chae-Joo;Jang, Yung-Hak;Lee, Hyun-Ju
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.424-428
    • /
    • 2004
  • A wind turbine system converts wind energy into electric energy, the system operated under normal environmental conditions. In case of particular turbulent wind flow such as typhoon, hurricane etc, the control of a blade used to a yaw control and a pitch control method. A small wind turbine has not a speed control system to only a manual tail safety brake. This paper shows a automatic tail safety brake controller based on feedback control using wind velocity. The controller composed of wired motor, relay system, steel wired motor him down a perpendicular to wind flow and then the blade speed reduced high to zero. The operation of automatic tail safety controller verified by manual test.

  • PDF

Design and Implementation of Large Capacity Cable Checking System using an I/O Buffer Method (입.출력 버퍼방식을 이용한 대용량 케이블 점검 시스템 설계 및 구현)

  • 양종원
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.103-115
    • /
    • 2002
  • This paper describes the results on the design and implementation of large capacity cable checking system using I/O buffer method. The I/O buffer module which has feedback loops with input and output buffers is designed with logic gate in the VME board and controlled by MPC860 microprocessor. So this system can check a lot of cable at the same time with less size and less processing time than that of relay matrix method with the A/D converter. The size of the I/O buffer module can be variable according to the number of cable. And any type of cable can be checked even if the pin assignment of cable is changed.

A Fuzzy Expert System for Auto-tuning PID Controllers (PID제어기의 자동조정을 위한 퍼지 전문가시스템)

  • Lee, Kee-Sang;Kim, Hyun-Chul;Park, Tae-Geon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.436-438
    • /
    • 1993
  • A rule based fuzzy expert system in self-tune PID controllers is presented in this paper. The rule base. the core of the expert system, is extracted from the Wills' tuning map and the author's knowledge about the implicit relations between PID gains and controlled output response. The overall control system consists of the relay feedback scheme and the expert system, where the one is responsible for initial tuning and the other for subsequent tuning. The PID control system with the proposed fuzzy expert system, shows better convergence rate and control performances than those of a Litt in spite of the fact that the two rule bases are extracted from the same maps provided by Wills.

  • PDF

Power Allocation Strategy for Soft-Decision-and-Forward Cooperative Communication System (연판정 후 전달 방식에 대한 전력 분배 전략)

  • Song, Kyoung-Young;Kim, Jae-Hong;No, Jong-Seon;Chung, Ha-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, the performance of the soft-decision-and-forward (SDF) protocol in the cooperative communication network with one source, one relay, and one destination, where each node has two transmit and receive antennas, is analyzed in terms of the bit error rate (BER) obtained from the pairwise error probability (PEP). For the slow-varying Rayleigh fading channel, the optimal and suboptimal power allocation ratios are determined without feedback. The optimal power allocation can be obtained by minimizing the average PEP. For the tractability, an alternative strategy of maximizing the product SNR of direct and relay links, which we call the suboptimal power allocation, is considered. Through the numerical analysis, we show that the performance gap between the suboptimal and the optimal power allocation is negligible in the high SNR region.

Model Identification and Design of Optimized IMC-Cascade Controller (모델 동정과 최적의 IMC-Cascade 제어기 설계)

  • Cho, Joon-Ho;Cho, Hyun-Seob;Hwang, Hyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6027-6033
    • /
    • 2012
  • In this paper, we proposed to model identification in frequency domain using relay feedback and Design of internal model controller(IMC) with Cascade controller. The parameters of controller in the inner loop are determined to minimize the integral of time multiplied by the absolute value of error (ITAE) value of performance Index. The controller of outer loop and parameters of IMC-PID controller can be obtain using identified model. The model identification is considered that it is the transient response and the steady-state response through the use of nyquist curve. Simulation examples are given to show the better performance of the proposed method than conventional methods.

The Design of Two-Way Automatic Communication System using Mobile Instant Messenger (모바일 인스턴스 메신저를 이용한 양방향 자동화 통신 시스템 설계)

  • Lee, Daesik;Lee, Yongkwon;Jang, Chungryong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.97-109
    • /
    • 2015
  • In this paper, we design and implement a two-way automatic communication system using a mobile instant messenger that can provide a customized service through a real-time two-way communication using a mobile instant messaging service. Two-way automatic communication system using a mobile instant messenger can improve the quality and quantity of information in real-time update of the information through the feedback. In addition, since it is communicated by using a mobile Instant Messanger in 1:1 there is no concerns that is recognized as spam, as well as it is possible to provide customized information for each user. Two-way automatic communication system using a mobile instant messanger shows the difference of the speed according to the data input time in typing by hands in result of comparing the time to input a date and the processing speed to search a data. Therefore in category treatment, command processing and natural language processing, Category treatment way is the most excellent in aspect of data processing speed, otherwise in aspect of the total speed to combine the data input time and the processing time, the command processing way is the best method.

The Design and Implementation of Automatic Communication System using Mobile Instant Messenger (모바일 인스턴스 메신저를 활용한 자동화 커뮤니케이션 시스템 설계 및 구현)

  • Kim, Tae Yeol;Lee, Dae Sik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.3
    • /
    • pp.11-21
    • /
    • 2014
  • In this paper, concerning the various advertising and policy advertising of the election with respect to whether to deliver a message to a large number of people, we design and implement an automative system what enables sending the text messages directly from the server to the client and also fast feedback is enabled by utilizing a number of operational programs to connect to the server. Therefore, we design and implement the automative communication system which enables delivering message to each user mobile terminal from a plurality of relay mobile terminals by utilizing the mobile instant messenger, not to deliver a message from the server to the mobile instant messenger user directly. In result of comparative analysis on the number of times of data transmission, this automative communication system utilizing mobile instant messenger shows the result that it enables transmitting five times per minute as it can copy and paste in the automation system regardless of the size of the data loading, otherwise in case of transmitting manually it show the result that the number of times of data transmission is reduced if the size of the data is larger.