• Title/Summary/Keyword: relay feedback

Search Result 73, Processing Time 0.024 seconds

A New Auto-Tuning PI Controller by Pattern Recognition (패턴 인식에 의한 새로운 자동조정 PI제어기)

  • Park, Gwi-Tae;Lee, Kee-Sang;Park, Tae-Hong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.696-705
    • /
    • 1991
  • This paper describes the procedures for pre-tuning and re-tuning the gains of PI controller based on output patterns -output error integral- of the unknown process which may not have any information, for example, system order, deadtime, time constant, etc. The key ideas of the proposed adaptive scheme are as follows. The scheme determines the initial gains by using ZNM (Ziegler-Nichols Method) with relay feedback, and then the adaptive algorithms by pattern recognition are introduced for re-runing the PI gains with on-line scheme whenever control conditions are changed. Because, among the various auto-tuning procedures, ANM with relay feedback has the difficulty in re-tuning with on-line and Bristol method has no comment on initial settings and has variables to pre-determine, which makes the algorithm comples, the proposed methods have the combined scheme with above two procedures to recover those problems. And this paper proposes a simple way to determine adaptive constant in Bristol method. To show the validity of the proposed method, an example is illustrated by computer simulation and a laboratory process, heat exchanger, is experimented.

A study on the application of the intelligent control algorithms to the flow control system (유량제어계통에 대한 지능형 제어 알고리즘 적용연구)

  • 김동화;조일인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1792-1795
    • /
    • 1997
  • It is difficulte to control in the flow system because there are many disturbance. So it is impossible to control delicately sometimes by PI or PID. In this paper, we study on the application of intellignet control algorithms such as 2DOF PID control, neural network, Fuzzy contro, Relay feedback to the flow control system. the resultings are 2DOF-PID control is more good response.

  • PDF

Determination of Effective Relay Candidates for the Best Relay Selection in Wireless Systems in the Presence of Interference (간섭이 존재하는 무선 시스템에서 최적의 중계 노드 선택을 위한 효과적인 중계 노드 후보 결정 방법 연구)

  • Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2812-2817
    • /
    • 2013
  • In this paper, an outage probability for the best relay selection in decode-and-forward relaying systems in the presence of interference is analyzed over Rayleigh fading channels. Based on the outage performance results, we propose a method to determine effective relay candidates for the best relay selection, where the effective relay candidates represent the relays except for relays that make no contribution to improving the performance. in all possible relays given in the system. By determining the effective relay candidates, the feedback overhead of channel state information and the energy consumption of relays can be significantly reduced while minimizing the performance degradation. In this paper, we provide important parameters that affect the determination of the effective relay candidates.

Experimental Test Time Reduction Method for Step Responses Using the Time-Optimal Control Technique (시간최적제어 기법을 이용한 계단응답 실험시간 단축 방법)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.190-196
    • /
    • 2020
  • The step to obtain a process dynamic model through process experiments is very important because it needs times and expenditures. Step response method is one of the standard methods to have long been used for understanding process dynamics, obtaining dynamical models and designing control systems. For the step response, it is usually required to measure process output for a step input change in the open-loop manner. Its disadvantage criticized is the long open-loop operation. For this, a method based on the time-optimal control technique to minimize the test time for obtaining the step response has been recently presented. However, the method requires iterative computations for the minimization of test times. Here, a method where iterative computations are not required is proposed. Simulation results are presented to show that test times to obtain step responses are reduced considerably and an autotuning method based on the proposed method is compared with the relay feedback autotuning method accepted widely for the autotuning of controllers.

Joint Lattice-Reduction-Aided Precoder Design for Multiuser MIMO Relay System

  • Jiang, Hua;Cheng, Hao;Shen, Lizhen;Liu, Guoqing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.3010-3025
    • /
    • 2016
  • Lattice reduction (LR) has been used widely in conventional multiple-input multiple-output (MIMO) systems to enhance the performance. However, LR is hard to be applied to the relay systems which are important but more complicated in the wireless communication theory. This paper introduces a new viewpoint for utilizing LR in multiuser MIMO relay systems. The vector precoding (VP) is designed along with zero force (ZF) criterion and minimum mean square error (MMSE) criterion and enhanced by LR algorithm. This implementable precoder design combines nonlinear processing at the base station (BS) and linear processing at the relay. This precoder is capable of avoiding multiuser interference (MUI) at the mobile stations (MSs) and achieving excellent performance. Moreover, it is shown that the amount of feedback information is much less than that of the singular value decomposition (SVD) design. Simulation results show that the proposed scheme using the complex version of the Lenstra--Lenstra--Lovász (LLL) algorithm significantly improves system performance.

Analysis of the congestion control scheme with the discard eligibility bit for frame relay networks (프레임 릴레이망에서의 DE 비트를 사용하는 혼잡제어 방식의 성능해석에 관한 연구)

  • 이현우;우상철;윤종호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.2027-2034
    • /
    • 1997
  • Frame relay is a fast packet switching technology that performs relaying and multiplexing frames with variable lengths over a wide area link at the T1 or E1 speed, by elminating error and flow control in the network. In frame relay networks, congestion control is typically performed through the rate enforcement with a discard eligibility (DE) bit, and the explicit negative feedback meachanisms using explicit congetion notification bits. In this paper, we consider the congestiong control scheme using the rate enforcement mechanism with DE bit for frame relay network. Assuming that each frame with exponentially distributed length arrives according to the Poission fashion, we can treat the frame relay switch as an M/M/1/K priority queueing system with pushout basis. We analyze and present the blocking probabilities and waiting time distributions of frames.

  • PDF

A Synchronization Technique for OFDM-based Full Duplex Relays with Frequency-domain Feedback Interference Canceller (주파수 영역 궤환 간섭 신호 제거기를 갖는 OFDM 기반 전이중 릴레이를 위한 동기화 기법)

  • Yoo, Hyun-Il;Woo, Kyung-Soo;Park, Chang-Hwan;Kim, Jae-Kwon;Jung, Sung-Yoon;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6A
    • /
    • pp.468-475
    • /
    • 2009
  • In OFDM-based Full Duplex Relays (FDR) with Decode and Forward (DF) scheme, an interference cancellation technique in the frequency domain is more efficient than the one in the time domain. However, an Inter-Symbol Interference (ISI) and Inter-Carrier Interference (ICI) may occur due to the timing mismatch between the feedback interference signal and the desired signal from Base Station (BS) when the feedback interference cancellation and demodulation are performed in the frequency domain. In this paper, the effects of timing mismatch on the synchronous type and asynchronous type of OFDM-based FDR are analyzed for uplink and downlink cases. Then, synchronization procedure and methods for reducing ISI and ICI in OFDM-based FDR with frequency-domain feedback interference canceller are proposed and verified by computer simulation.

Novel Equalization On-Channel Repeater with Feedback Interference Canceller in Terrestrial Digital Multimedia Broadcasting System

  • Park, Sung-Ik;Eum, Ho-Min;Park, So-Ra;Kim, Geon;Lee, Yong-Tae;Kim, Heung-Mook;Oh, Wang-Rok
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.357-364
    • /
    • 2009
  • In this paper, we propose a novel equalization on-channel repeater (OCR) with a feedback interference canceller (FIC) to relay terrestrial digital multimedia broadcasting signals in single frequency networks. The proposed OCR not only has high output power by cancelling the feedback signals caused by insufficient antenna isolation through the FIC, but also shows better output signal quality than the conventional OCR by removing multipath signals existing between the main transmitter and the OCR through an equalizer. In addition, computer simulations and laboratory test results demonstrate that the proposed OCR successfully cancels feedback signals and compensates channel distortions and provides a higher quality transmitting signal with higher output power than conventional OCRs.

Auto-Tuning PID Controller using Some Heuristic Rules (경험적 규칙을 이용한 자동 동조 PID제어기)

  • 이창구;김성중;황형수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.5
    • /
    • pp.485-493
    • /
    • 1990
  • The idea of expert control is to incorporate a rule based expert system in a feedback control system. In this paper, we present some heuristic rules based on relay experiment for the choice of controller structure and the setting of the controller parameters. Heuristic rules are used as an element of the feedback loop in an auto-tuning PID controller. The algorithms are coded in a form which is as pure as possible and the heuristic logic is implemented with the rules. This paper reports an implementation of an expert controller on microcomputer-based system, including an industrial programmable controller.

PID Autotuning Based on Saturation Function Feedback with A Static Load Disturbance (정적 부하왜란이 있는 경우의 포화함수를 이용한 PID 자동동조)

  • Oh, Seung- Rohk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.12
    • /
    • pp.542-548
    • /
    • 2002
  • We consider an unknown linear time invariant plan with static load disturbance. A saturation function nonlinear element is sued to find th one point information in the frequency domain. We analyze an asymmetric self-oscillation caused by static load disturbance with relay feedback and saturation function feedback. We propose a new method to tune a PID controller using a saturation nonlinear feedback element in the presence of asymmetric oscillation. The proposed method does not require the knowledge of plant d.c. gain with an asymmetric oscillation in the plat output.