• Title/Summary/Keyword: reinforced bridge

Search Result 728, Processing Time 0.033 seconds

Repair of Highway Bridge Damaged by Chloride Attack in Marine Environment(l) - Investigation/Diagnosis and Repair (해상에 위치한 고속도로교량에 대한 내염보수 공법 적용(1) - 염해조사 및 보수계획)

  • Cheong Haimoon;Ahn Tas-Song;Ryu Jong-Hyun;Chi Han-Sang;Han Bog-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.822-825
    • /
    • 2004
  • Corrosion of reinforced concrete structures in marine environment is one of the most important mechanism of deterioration. The conventional repair techniques of concrete structure damaged by chloride attack consist of removing damaged concrete, cleaning rebar and patching with cement-based materials. However, recently, this method was considered to be ineffective for marine concrete structure in tidal zone. It is necessary to select proper repair method for domestic marine environment which shows broad tidal zone. This paper reports the results of repair of highway concrete bridge damaged by chloride attack in domestic marine environment.

  • PDF

Repair of Highway Bridge damaged by Chloride Attack in Marine Environment(2) - Application of Cathodic Protection (해양에 위치한 고속도로교량에 대한 내염보수 공법(2)-전기방식시공결과)

  • Chi, Han-Sang;Han, Bog-Kyu;Cheong, Hai-Moon;Ahn, Tae-Song;Ryu, Jong-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.786-789
    • /
    • 2004
  • Corrosion of reinforced concrete structures in marine environment is one of the most important mechanism of deterioration. However, conventional rehabilitation techniques in tidal zone, which consist of removing delaminated areas of concrete, cleaning affected steel and patching with portland cements mortar, have proven to be ineffective for marine structures. Also, repairs are often repeated every several years. The purpose of this report is to announce appropriate repair method of highway bridge damaged by chloride attack in marine environment (application of cathodic protection) using FRP and antiwashout underwater mortar.

  • PDF

Displacement Behavior of Tunnel under Bridge Abutment due to Supporting Systems (교량기초 하부에 위치한 터널의 지보방법에 따른 변위거동)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Kim, Seung-Ryul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.613-620
    • /
    • 2005
  • This research is experimental paper to prepare the structural safety of the upper bridge for support type on tunnel and the effect of settlement. Unit weight test and uni-axial compression test have been performed to simulate the physical property of foundation on the tunnel. Tunnel model of slip form type for centrifuge model has been developed to performed the tunnel excavation while field stress is activated. And the support type of tunnel such as umbrella arch method and large diameter steel pipe reinforce method has been tested for the centrifuge model. After the analysis of experiment, results show that internal displacement of large diameter steel pipe reinforce method is smaller than that of the umbrella arch method.

  • PDF

Bi-Axial Alternate Cyclic Loading Test of Rectangular Reinforced Concrete Columns (이축방향 교번반복하중을 받는 구형 철근콘크리트교각의 거동특성 시험)

  • 김재관;김익현;이재호;김남식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.323-328
    • /
    • 2001
  • The behavior of bridge column under multi-directional loading as well as uni-directional loading need to be studied because bridge columns will be subjected to the multi-directional cyclic loading during a strong earthquake. To evaluate the capacity of columns, uni-axial cyclic loading tests and bi-axial alternate cyclic loading tests were carried out. The number of cycles of alternate bi-axial loading were determined considering the ratio of natural frequencies in two orthogonal directions. From the test results, strength degradation and ductility reduction were observed in biaxial loading conditions. Their rates were found to be more rapid in the loading pattern that was determined considering the different natural frequencies.

  • PDF

Analytical Model for CFTA Girder (CFTA 거더의 해석모델 개발)

  • Jeon, Jong-Su;Park, Seung-Jae;Kim, Yong-Jae;Park, Myoung-Gyun;Kim, Jung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.169-170
    • /
    • 2009
  • CFT structure has many advantages compared with the ordinary structural member made of steel or reinforced concrete. Because of increases in ductility, stiffness and load carrying capacity of overall structure owing to confinement effect of steel box and concrete, CFT structure is widely used to columns. Recently, the utilization of CFT member has been expanded to bridge structure as a girder member. The purpose of this study is to develop the analytical model and propose design method for CFTA girder bridge consisting of CFT structure, arch shape and tendons.

  • PDF

The analysis of RC bridge piers on shaking table test by using Nonlinear program (비선형 해석프로그램을 이용한 RC교각의 진동대 시험 분석)

  • Yang, Dong-Wook;Park, Young-Kwon;Lee, Yeon-Hun;Chung, Young-Soo;Lee, Dae-Hyoung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.67-68
    • /
    • 2009
  • This research aims at investigating the seismic behavior of RC bridge piers subjected to NFGM in low or moderate seismic region according to Volumetric Confinement Steel Ratio through the shaking table test unlike original way of the test. This investigation deal with the estimate with SARCF for shaking table test by the comparative analysis for the value of FFT.

  • PDF

Seismic Retrofit of RC Columns with Lap-Spliced Longitudinal Rebars Wrapping by SMA Wires (SMA Wire를 이용한 주철근 겹침이음된 RC 교각의 내진 보강 연구)

  • Park, Yong-Kwon;Lee, Yeon-Hun;Yang, Dong-Wook;Lim, Hyeon-Sik;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.129-130
    • /
    • 2010
  • Lap splice of longitudinal reinforcing steels was located in the plastic hinge region of most bridge piers that had been designed and constructed before the adoption of the 1992 seismic design provision of Korea Highway Design Specification. This research aims at improving the seismic performance of reinforced concrete bridge piers with lap-spliced longitudinal steels, of which the plastic hinge region was wrapped by the shape memory alloy (SMA) wires. Quasi-static test was used to investigate the seismic behaviours of RC test specimens.

  • PDF

Structural Performance Evaluation for the Precast Shell type Pier Cap (PC Shell 형식 피어캡의 구조성능 평가)

  • Shin, Sung-Jin;Hwang, Do-Kyu;Lee, Jae-Hoon;Son, Je-Kuk;Park, Dong-Kyu;Yoo, Dong-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.81-82
    • /
    • 2010
  • As a part of rapid construction technology of bridge pier caps, controversial issues for design and construction of precast pier caps were discussed. Three kinds of approaches of rapid bridge pier cap construction were proposed and discussed. Especially for an approach of precast shell type structures, experimental studies were performed to evaluate structural performance and compared with conventionally constructed reinforced concrete pier cap.

  • PDF

Development of strut-and-tie model and design guidelines for improved joint in decked bulb-tee bridge

  • Li, Lungui;He, Zhiqi;Ma, Zhongguo John;Yao, Lingkan
    • Structural Engineering and Mechanics
    • /
    • v.48 no.2
    • /
    • pp.221-239
    • /
    • 2013
  • This paper focuses on a development of strut-and-tie model (STM) to predict the capacity of an improved longitudinal joint for decked bulb-tee bridge systems. Nine reinforced concrete beam/slab specimens anchored by spliced headed bars with different details were tested. Test results were evaluated and compared with an anticipation of the validated STM. The proposed STM provides a lower bound of the ultimate capacity of the joint zone. It shows that the lap length of headed bars has a significant effect on structural behaviors of the improved joint. To develop a full strength joint, the range of the lap length can be determined by the strength and compatibility requirement. Design recommendations to spliced headed bars, concrete strength, as well as lacer bars in the joint zone are proposed for developing a full strength joint.

Engineering Technology Far-end Telecontrol Cathodic Protection on the Structure of Jetty Bridge Cap Beams

  • Liu, Yi-Hsiung;Lim, Pau-Yee;Shih, Chien-Chis
    • Corrosion Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.47-52
    • /
    • 2003
  • 23 cap beams on the 1 Km length jetty bridge in Shin-da power plant (Taipower co., Taiwan) utilize far-end telecontrol cathodic protection technology which is the first case ever used in Taiwan. The system comprises cathodic protection system and te1econtrol monitoring system. The control and monitoring such as protection current adjustment, protection potential and depolarization measurement of the 23 cap beams can be adjusted through system telecontrol operations. Thereby allows monitoring and control of the 23 anode zones in a convenient and cost effective way. This system is at present still in its best running condition since Sept. 1997 when it was completed. All the 23 cap beams can achieve the 100 mV depolarization potential criteria of protection. It meet the specifications of reinforced concrete cathodic protection standard and proved to be very excellent.