• 제목/요약/키워드: reduction-scale experiment

검색결과 163건 처리시간 0.042초

Removal of EDCs from Industrial Sludge by Electron Beam

  • Han, Bumsoo;Kim, Jinkyu;Kim, Yuri;Jung, Seungtae;Park, Junhyung;Choi, Jangseung
    • 방사선산업학회지
    • /
    • 제8권2호
    • /
    • pp.71-76
    • /
    • 2014
  • Endocrine disrupting chemicals (EDCs) and potential EDCs are mostly man-made, found in various materials such as pesticides, additives or contaminants in food, and personal care products. The high energy ionizing radiation has the ability to remove the EDCs with a very high degree of reliability and in a clean and efficient manner. The ionizing radiation interacts with EDCs both directly and indirectly. Direct interaction takes place with EDCs and the structure of EDCs is destroyed or changed. During indirect interaction, radiolysis products of water result in the formation of highly reactive intermediates which then react with the target molecules, culminating in structural changes. To confirm the radiation reduction of EDCs in industrial sludge, a pilot scale experiment up to 50 kGy of electron beam (EB) was conducted with samples from the textile dyeing industries. The experimental result showed the over 90% of reduction of Nonylphenol (NP) and Di(2-ethylhexyl) phthalate (DEHP) at around 10 kGy of absorbed doses.

담수조건에 따른 토양 내 중금속 용출특성과 안정화공법의 효과 검토 (An Investigation on the Effect of Stabilization Methods and Leaching characteristics of Heavy Metals in Paddy Soils contaminated by Heavy Metal under Submerged Condition)

  • 유찬;윤성욱;강신일;진혜근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1201-1212
    • /
    • 2010
  • In order to investigate on the effect of stabilization methods for rice paddies contaminated by heavy metals, a series of lab-scale model test was carried out by applying the characteristics of submerged Paddy soil. To perform the lab-scale model test, columns were made by acrylic with the dimension of diameter=10cm, thickness=0.5cm and were filled with soils which was contaminated were mixed with stabilization agents(lime stone 5% and steel refining slag 5% respectively). To manipulate the reduction condition, soils in the columns were submerged with distilled water. And then soil water and subsurface water in each column were sampled in the regular term and analysed the various physical and chemical properties.

  • PDF

축소모형을 이용한 실내 수공간 도입 효과 연구 (A Study on the Change of Indoor Heating Environment with the Creation of Indoor Water Space through a Scale Model)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was conducted to examine the change of heating environment with the creation of an indoor water space. Living environments and comfort of dwellers can be improved by utilizing the physical properties of water effectively. This study focuses on the basic examination of the effect of water space and the environmental effects of water space by experiment. Two identical models were fabricated to compare the changes in indoor temperature and humidity with and without a water space. With the water space, temperature was reduced by an average of $0.55^{\circ}C$ a day and moisture content increased by an average of 4%. As a result, it was possible to obtain quantitative data on water space's temperature reduction and humidity control capacities. This study is expected to provide basic information for further studies on the effect of water spaces in various buildings.

2중방진 시스템의 실험적 거동해석 (Experimental Behavior Analysis of Double Isolated Anti-Vibration System)

  • 이홍기;이신언
    • 소음진동
    • /
    • 제2권4호
    • /
    • pp.281-292
    • /
    • 1992
  • Two types of vibration problems are encountered in industrial field: active isolation and passive isolation. In a passive type of vibration isolation, a foundation of a delicated machinery such as TEM, SEM, inspection- probe test, photolithograph, etc. is designed to have a vibration amplitude lower than an acceptable limit. In an active type, the isolation is focused on the vibration reduction caused by the machine itself(pump, motor, press, compressor, etc.). The foundation for such a machine should be so designed as to reduce the transmitted vibration below the permissible level prescribed. At any case, a transmissibility and stability must to be considered. Since an active isolation type is aimed for a vibration source, it is useful to isolate the transmitted vibrations energy from a major vibration source at the specific location. In this paper, a designed methodology of double anti-vibration system has been examined in order to have low transmissibility and reliable stability. Also experiment of scale model behavior has been conducted. Finally, the experiment output of the transfer function is compared to the analytical data.

  • PDF

양이온 교환막을 이용한 이산화탄소의 전기화학적 환원 (Electrochemical Reduction of Carbon Dioxide Using a Proton Exchange Membrane)

  • 김학윤;안상현;황승준;유성종;한종희;김지현;김수길;장종현
    • 전기화학회지
    • /
    • 제15권4호
    • /
    • pp.216-221
    • /
    • 2012
  • 전기화학적 환원을 통한 이산화탄소의 활용을 위한 노력은 오래 전부터 계속되어 왔다. 최근에는 액체연료 중 가격이 비싸고 그 활용도가 높은 포름산의 생성을 위한 연구가 많이 진행되고 있지만 실제 포름산을 생성하고 분석하는 과정에서 효율의 개선과 분석에 어려움이 따른다. 따라서 이산화탄소 환원을 이용한 포름산 생성에 필요한 시스템의 제조, 반응 조건의 개발 및 분석 방법의 정량화가 필요하다. 본 연구에서는 이산화탄소의 전기화학적 환원을 통한 포름산의 생성을 진행하고 생성된 포름산의 양을 분석하였다. 실험에 이용된 셀은 양이온 교환막을 사용하는 대용량의 회분형 셀을 이용하였으며 전위차계를 통하여 삼전극에서 전기화학 실험을 진행하였다. 전기화학 실험은 다양한 촉매 금속을 이용하여 선형 전위 주사법과 chronoamperometry를 통해 진행했으며 이 때 기준전극은 염화은 전극을 이용하였고 상대전극은 백금 전극을 사용하였다. 실험을 통해 생성된 포름산의 농도를 high performance liquid chromatography(HPLC)를 통하여 분석하여 시스템의 적정성과 분석 방법의 유효성을 검증하였다.

선망어업의 생산성 향상에 관한 연구-III - 죔줄 체결시 파워불록과 트리플랙스용 선망 모형의 유속에 따른 운동특성 - (Studies on the improvement of the productivity of purse seine fishery-III - The characteristics on the motion with the flow velocity of model purse seine of the subjective power block and triplex during pursing -)

  • 김석종
    • 수산해양기술연구
    • /
    • 제43권1호
    • /
    • pp.12-27
    • /
    • 2007
  • This fundamental studies on for the productivity improvement and laborsaving of purse seine fishery. Given the difficulty posed from the distortion of net shape caused by the external forces, such as tide, at the time of shooting and pursing, we set the 4 steps of 0, 2, 4 and 6cm/sec in flow velocity in the flume tank for the experiment in order to examine those characteristics. We used two model seines designed on the scale of 1 to 180 based on the power block seine, which is the mackerel purse seine generally used in the near sea of Jeju Island and triplex seine, which is the mackerel purse seine of one boat system fishing expected in the future, for the experiment, and interpreted the characteristics of several motion in water, such as the shape of seine, the change in tension and area during pursing and its the analysis results are as follows. Though the experiment could be conducted up to 6cm/sec of flow velocity that was defined, the experiment could not go on because of the severe distortion in the seine at the flow velocity in excess of 6cm/sec. As for the depth of leadline and reduction rate of side area of seine when the pursing is connected, P seine turned out to be slightly higher than T seine, and the hauling speed and reduction rate of upper area of seine were found similar to each other. The correlation between the hauling time (Ht) and depth of lead line (Dhp, Dht) of P seine and T seine can be expressed by the equation, that is, Dhp=(0.99Pt-7.63)Pt+69.01, Dht=(1.03Pt-7.73)Pt+66.74. The correlation between the hauling time and hauling velocity (Hpp, Hpt) can be expressed by the equation, that is, $Hpp=-0.06Ht^2+0.88Ht+0.78,\;Hpt=-0.05Ht^2+0.81Ht+0.98$ here, Pt is pursing time. And the correlation between the pursing time and the reduction rate of side area (sArp, sArt) can be expressed by the equation, that is, $sArp=-0.48Pt^2+14.79Pt-16.74,\;sArt=-0.45Pt^2+14.56Pt-16.48$. The reduction rate of upper area of seine (tArp, tArt) can be expressed by the equation, that is, $tArp=0.34Pt^2-0.66Pt-0.74,\;tArt=0.34Pt^2-0.27Pt-1.80$. In addition, the correlation between the pursing time and tension of purse line (Tep, Tet) can be expressed by the equation, that is, $Tep=2.79Pt^2+2.26Pt-0.60,\;Tet=2.14Pt^2+8.08Pt-27.50$.

공기 및 연료에 대한 배기가스 희석 방법에 의한 저 $NO_x$ 연소특성에 관한 실험 (Experiment on Low $NO_x$ Combustion Characteristics by Flue Gas Dilution In Air and Fuel Sides)

  • 조은성;정석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1499-1504
    • /
    • 2004
  • Flue gas recirculation (FGR) is a method used to control oxides of nitrogen ($NO_x$) in combustion system. The recirculated flue gases resulted in slow reaction and low flame temperatures, which in turn resulted in decreased thermal NO production. Recently, it has been demonstrated that introducing the recirculated flue gas in the fuel stream, that is, the fuel induced recirculation (FIR), resulted in a much greater reduction in $NO_x$ per unit mass of recirculated gas, as compared to introducing the flue gases in air. In the present study, the effect on $NO_x$ reduction in turbulent swirl flame in laboratory scale using FGR/FIR methods through the dilution using $N_2$ and $CO_2$. Results. show the $CO_2$ dilution is more effective $NO_x$ reduction methods because of large temperature drop due to the larger specific heat $CO_2$ compared to $N_2$. FIR is more effective to reduce $NO_x$ emission than FGR when the same recirculation ratio of dilution gas.

  • PDF

심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로- (Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment-)

  • 정연희;양영모
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

Removal of iron oxide scale from boiler feed-water in thermal power plant by high gradient magnetic separation: field experiment

  • Akiyama, Yoko;Li, Suqin;Akiyama, Koshiro;Mori, Tatsuya;Okada, Hidehiko;Hirota, Noriyuki;Yamaji, Tsuyoshi;Matsuura, Hideki;Namba, Seitoku;Sekine, Tomokazu;Mishima, Fumihito;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.14-19
    • /
    • 2021
  • The reduction of carbon dioxide emissions becomes a global issue, the main source of carbon dioxide emissions in the Asian region is the energy conversion sector, especially coal-fired power plants. We are working to develop technologies that will at least limit the increase in carbon dioxide emissions from the thermal power plants as one way to reduce carbon dioxide emissions. Our research aims to reduce carbon dioxide emissions by removing iron oxide scale from the feedwater system of thermal power plants using a superconducting high-gradient magnetic separation (HGMS) system, thereby reducing the loss of power generation efficiency. In this paper, the background of thermal power plants in Asia is outlined, followed by a case study of the introduction of a chemical cleaning line at an actual thermal power plant in Japan, and the possibility of introducing it into the thermal power plants in China based on the results.

관절 질환의 통증과 가동력에 파라핀 치료가 미치는 효과 (The Effect of Paraffin Therapy on Release of pain and Range of motion with Joint Disease Patients)

  • 이석민;권기자
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.130-139
    • /
    • 2003
  • This study was conducted in order to determine the effect of Paraffin Therapy on release of pain, skin temperature and range of motion with joint diseases. This study was performed on 42 patients with general joint diseases and 21 patients with degenerative joint diseases. All the subjects were randomly assigned to three groups with 21 each. The experiment had been done from June, 1. 2002 to September, 30. 2002, in two general hospitals and a social welfare center using Digital Thermometer Kane-May KM330 and VAS(visual analogue scale). Each pint was measured in terms of skin temperature, pain scale and ROM(range of motion). The results of the experiment are as follows : 1. In application of three different heat modalities (Paraffin bath, Infra red, Hydro pack) on the Knee, Ankle, Elbow pints of the subjects for 30 minutes, the elevation of skin temperature and the reduction of pain scale were found to be significantly different. When checked right after the 30 minutes' application, the Infra red resulted in a higher degree elevation of skin temperature than two other modalities, while Paraffin bath resulted in the highest degree of the elevation of skin temperature when it was checked one hour after the application was over. It means that Paraffin bath lasted longer than the other two modalities(F=14.691, p<.000). 2. With Paraffin bath application, pint pain was reduced significantly both in 30 minutes and one hour checks(F=20.675, p<.001). 3. In terms of ROM(range of motion) increase, didn't seem to have any significant differences in 30 minutes and one hour. The results suggest that Paraffin therapy be helpful in maximizing th effects on pint diseases. I strongly suggest that further studies be done on other pints and muscle diseases using Paraffin bath in different methods of applying the therapy.

  • PDF