• Title/Summary/Keyword: reduction device

Search Result 1,282, Processing Time 0.03 seconds

Integer-Pel Motion Estimation for HEVC on Compute Unified Device Architecture (CUDA)

  • Lee, Dongkyu;Sim, Donggyu;Oh, Seoung-Jun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.397-403
    • /
    • 2014
  • A new video compression standard called High Efficiency Video Coding (HEVC) has recently been released onto the market. HEVC provides higher coding performance compared to previous standards, but at the cost of a significant increase in encoding complexity, particularly in motion estimation (ME). At the same time, the computing capabilities of Graphics Processing Units (GPUs) have become more powerful. This paper proposes a parallel integer-pel ME (IME) algorithm for HEVC on GPU using the Compute Unified Device Architecture (CUDA). In the proposed IME, concurrent parallel reduction (CPR) is introduced. CPR performs several parallel reduction (PR) operations concurrently to solve two problems in conventional PR; low thread utilization and high thread synchronization latency. The proposed encoder reduces the portion of IME in the encoder to almost zero with a 2.3% increase in bitrate. In terms of IME, the proposed IME is up to 172.6 times faster than the IME in the HEVC reference model.

Application of the Seismic Response Reduction Technology for Boramae Deokyo Building Remodeling (보라매 대교빌딩 리모델링을 위한 지진응답 저감기술 적용사례)

  • Park, Young-Mi;Park, Ki-Hong;Jo, Seong-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.134-136
    • /
    • 2013
  • In general, the seismic retrofit is almost essential to extend and remodel aged buildings. Because domestic seismic design code has been enhanced, seismic performance should be secure for aged building remodeling. Seismic response reduction device (damper) is lately appling to ensure seismic performance. This device is economical efficiency method that can reduce the load to foundation and the range of structural reinforcements, shorten of construction period. New shaped steel damper was applied for extension and remodeling construction for Boramae Deakyo building. As a result, the economy and shortening of construction period was achieved.

  • PDF

Static and Dynamic Characteristics of PT-IGBT by Proton Irradiation (양성자 주입 조건에 따른 PT-IGBT의 정특성 및 동특성 분석)

  • Choi, Sung-Hwan;Lee, Yong-Hyun;Bae, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.14-15
    • /
    • 2007
  • Proton irradiation technology was used for improvement of switching characteristics of the PT-IGBT. The proton irradiation was carried out at 5.56 MeV energy from the back side of processed wafers and at 2.39 MeV energy from the front side of the wafers. The on-state and off-state I-V characteristics and switching properties of the device were analyzed and compared with those of un-irradiated device and e-beam irradiated device which was conventional method for minority carrier lifetime reduction. The proton irradiated device by 5.56 MeV energy was superior to e-beam irradiated device for the on-state and off-state I-V characteristics, nevertheless turn-off time of proton irradiated device was superior to that of the e-beam irradiated device.

  • PDF

TWO-STEP THERMOCHEMICAL CYCLES FOR HYDROGEN PRODUCTION WITH DISH TYPE SOLAR THERMAL SYSTEM and $CeO_2/NiFe_2O_4$ (접시형 태양열 집광 시스템과 산화세륨 및 페라이트산화물을 이용한 열화학 사이클의 수소생산)

  • Kwon, Hae-Sung;Oh, Sang-June;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.113-119
    • /
    • 2012
  • The two-step water splitting thermochemical cycle is composed of the T-R (Thermal Reduction) and W-D (Water Decomposition) steps. The mechanism of this cycle is oxidation-reduction, which produces hydrogen. The reaction temperature necessary for this thermochemical cycle can be achieved by a dish-type solar thermal collector (Inha University, Korea). The purpose of this study is to validate a water splitting device in the field. The device is studied and fabricated by Kodama et al (2010, 2011). The validation results show that the foam device, when loaded with $CeO_2$ powder, was successfully achieved hydrogen production under field conditions. Through this experiment, we can analyze the characteristics of the catalyst and able to determine which is more advantageous thing to produce hydrogen compared with previous experiment that used ferrite-device.

  • PDF

Device Miniaturization Using Stepped Multimode-Interference Couplers (계단형 다중모드 간섭 결합기를 사용한 소자의 소형화)

  • Ho, Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • In this paper, a novel architecture for device miniaturization of multimode interference-based couplers (MMICs) is proposed by replacing conventionally designed MMICs by cascaded two-section stepped-width or stepped-index MMICs. For the 82% cross coupling efficiency in a stepped-width MMIC, the coupling length of device results in just 6.7% length reduction. However, for a stepped-width and stepped-index MMIC, the coupling efficiency increases to 93% and the length reduction of 9% occurs. Furthermore, with additional incorporation of tapered devices, it shows that a compact MMIC can be designed in which the coupling efficiency is 90% and the length is reduced to 25%.

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

Novel OLED structure allowing for the in-situ ohmic contact and reduction of charge accumulation in the device

  • Song, Won-Jun;Kristal, Boris;Lee, Chong-Hoon;Sung, Yeun-Joo;Koh, Sung-Soo;Kim, Mu-Hyun;Lee, Seong-Taek;Kim, Hye-Dong;Lee, Chang-Hee;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1014-1018
    • /
    • 2007
  • We have demonstrated the enhancement of the power efficiency and device lifetime of organic light-emitting diodes (OLEDs) by introducing the ETL 1 / ETL2 (composite ETL) structure between EML and cathode and the HIL1 (composite HIL) / HIL2 between anode and HTL. Compared to reference devices retaining conventional architecture, novel OLED structure shows an outstanding EL efficiency that is 1.6 times higher (${\sim}4.5$ lm/w versus ${\sim}$ 2.71 lm/w for the reference device) and lower driving voltage $({\bigtriangleup}V>1V)$, but also a longer lifetime and smaller operating voltage drift over time. It is suggested in this work that the device performance can be improved by in-situ ohmic contact through novel electron controlled structure and reduction of charge accumulation in the interface through composite HIL

  • PDF

A Modified Scheme of OFDM Transceiver for Reduction of Its Natural Delay

  • Kim, Dongkyu;Kim, Juyon;Seungkwon Baek
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1905-1908
    • /
    • 2002
  • In this paper, we analyze the natural processing delay of OFDM systems and proposed two modified unctional blocks to decrease about 25% of the total delay. e evaluate BER performance of the proposed scheme to e compared with that of classical one to confirm same performance between them.

  • PDF

Reduction of Radiation Dose for Injection of Radioisotope using Shielding Device (방사성동위원소 투여 시 차폐기구를 이용한 방사선 피폭 저감)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.291-296
    • /
    • 2019
  • Nuclear medicine have often used to diagnose cancers. The main absorbed dose from radiation to a radiation worker resulted from open radioisotopes. Methods for reducing the radiation dose to a radiation worker from radioisotopes injected to patients were studied. The shield device of 0.2 mmPb was manufactured as a size of $300mm{\times}500mm{\times}150mm$. By using dosimeters of Nanodot, the absorbed doses for thyroid, chest and genital organ were measured with and without a shielding device and with syringe shield and shielding device together. The highest absorbed dose of 0.908 mGy reduction of 20.8% as 0.719 mGy was in the genital organ by using the syringe shield and a shielding device together. A effective dose for a radiation worker during 1 year was expected to 1.223 mSv at the chest, which was decrease as 0.994 mSv by shielding device and syringe shield together. When open radioisotope is injected to a patient for examination, the only use of a shielding device results in the reduction of radiation dose to radiation workers.

AC Modeling of the ggNMOS ESD Protection Device

  • Choi, Jin-Young
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.628-634
    • /
    • 2005
  • From AC analysis results utilizing a 2-dimensional device simulator, we extracted an AC-equivalent circuit of a grounded-gate NMOS (ggNMOS) electrostatic discharge (ESD) protection device. The extracted equivalent circuit is utilized to analyze the effects of the parasitics in a ggNMOS protection device on the characteristics of a low noise amplifier (LNA). We have shown that the effects of the parasitics can appear exaggerated for an impedance matching aspect and that the noise contribution of the parasitic resistances cannot be counted if the ggNMOS protection device is modeled by a single capacitor, as in prior publications. We have confirmed that the major changes in the characteristics of an LNA when connecting an NMOS protection device at the input are reduction of the power gain and degradation of the noise performance. We have also shown that the performance degradation worsens as the substrate resistance is reduced, which could not be detected if a single capacitor model is used.

  • PDF