• 제목/요약/키워드: reduced bias

검색결과 281건 처리시간 0.02초

Improved Stability of Atomic Layer Deposited ZnO Thin Film Transistor by Intercycle Oxidation

  • Oh, Him-Chan;KoPark, Sang-Hee;Ryu, Min-Ki;Hwang, Chi-Sun;Yang, Shin-Hyuk;Kwon, Oh-Sang
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.280-283
    • /
    • 2012
  • By inserting $H_2O$ treatment steps during atomic layer deposition of a ZnO layer, the turn-on voltage shift from negative bias stress (NBS) under illumination was reduced considerably compared to that of a device that has a continuously grown ZnO layer without any treatment steps. Meanwhile, treatment steps without introducing reactive gases, and simply staying under a low working pressure, aggravated the instability under illuminated NBS due to an increase of oxygen vacancy concentration in the ZnO layer. From the experiment results, additional oxidation of the ZnO channel layer is proven to be effective in improving the stability against illuminated NBS.

Improved Circuits for Single-photon Avalanche Photodiode Detectors

  • Kim, Kyunghoon;Lee, Junan;Song, Bongsub;Burm, Jinwook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권6호
    • /
    • pp.789-796
    • /
    • 2014
  • A CMOS photo detection bias quenching circuit is developed to be used with single photon avalanche photodiodes (SPADs) operating in Geiger mode for the detection of weak optical signals. The proposed bias quenching circuits for the performance improvement reduce the circuit size as well as improve the performance of the quenching operation. They are fabricated in a $0.18-{\mu}m$ standard CMOS technology to verify the effectiveness of this technique with the chip area of only $300{\mu}m^2$, which is about 60 % of the previous reported circuit. Two types of proposed circuits with resistive and capacitive load demonstrated improved performance of reduced quenching time. With a commercial APD by HAMAMATSU, the dead time can be adjusted as small as 50 ns.

Characteristic of P doped ZnO-based thin film transistor by DC magnetron sputtering

  • Lee, Sih;Moon, Yeon-Keon;Moon, Dae-Yong;Kim, Woong-Sun;Kim, Kyung-Taek;Park, Jong-Wan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.540-542
    • /
    • 2009
  • Phosphorus doped ZnO (PZO) thin films were deposited on $SiO_2$/n-Si substrates using DC magnetron sputtering system varying oxygen partial pressures from 0 to 40 % under Ar atmosphere. The deposited films showed reduced n-type conductivity due to the compensating donor effects by phosphorus dopant. The bias-time stability shows relatively good stability over bias and time comparing to un-doped ZnO-based TFTs.

  • PDF

Magneetoelastic Resonators에 사용되는 새로운 비정질 함금 (Devised New Amorphous Alloys for Magneetoelastic Resonators)

  • 김창경;유충근; R.C. O'Handley
    • 한국표면공학회지
    • /
    • 제31권5호
    • /
    • pp.245-250
    • /
    • 1998
  • There is clear pressing need to reduce bias field(Ha,) used on linear magenetomechanical resonator tag by at least a factor of two to allow low-bias operation near the frequency minimum since reducing Ha causes a dramatic increase in well depth, which implies increased stability. However, this makes it more difficult to maintain tight frequncy specs. It can be solved by a reduction of magnetomechanical coupling(k). We determined from an equivalent circuit model that optimal reduced, k, is near 0.3 Also, We determiend the material properties($lambda_s$, :saturated magenetostriction, $M_s$, and,$H_a$) that give k=0.3. From these evaluations, we suggested that on optimal comosition with adequate mathrial properties is $Fe_{55}Co_{15}Cr_6Nb_2B_{18}Si_4$.

  • PDF

Bias-reduced ℓ1-trend filtering

  • Donghyeon Yu;Johan Lim;Won Son
    • Communications for Statistical Applications and Methods
    • /
    • 제30권2호
    • /
    • pp.149-162
    • /
    • 2023
  • The ℓ1-trend filtering method is one of the most widely used methods for extracting underlying trends from noisy observations. Contrary to the Hodrick-Prescott filtering, the ℓ1-trend filtering gives piecewise linear trends. One of the advantages of the ℓ1-trend filtering is that it can be used for identifying change points in piecewise linear trends. However, since the ℓ1-trend filtering employs total variation as a penalty term, estimated piecewise linear trends tend to be biased. In this study, we demonstrate the biasedness of the ℓ1-trend filtering in trend level estimation and propose a two-stage bias-reduction procedure. The newly suggested estimator is based on the estimated change points of the ℓ1-trend filtering. Numerical examples illustrate that the proposed method yields less biased estimates for piecewise linear trends.

Variable Selection with Nonconcave Penalty Function on Reduced-Rank Regression

  • Jung, Sang Yong;Park, Chongsun
    • Communications for Statistical Applications and Methods
    • /
    • 제22권1호
    • /
    • pp.41-54
    • /
    • 2015
  • In this article, we propose nonconcave penalties on a reduced-rank regression model to select variables and estimate coefficients simultaneously. We apply HARD (hard thresholding) and SCAD (smoothly clipped absolute deviation) symmetric penalty functions with singularities at the origin, and bounded by a constant to reduce bias. In our simulation study and real data analysis, the new method is compared with an existing variable selection method using $L_1$ penalty that exhibits competitive performance in prediction and variable selection. Instead of using only one type of penalty function, we use two or three penalty functions simultaneously and take advantages of various types of penalty functions together to select relevant predictors and estimation to improve the overall performance of model fitting.

R.F. 스퍼터링법에 의한 상변화형 광디스크의 $(ZnS)_{1-x}-(SiO_2)_x$ 보호막 제조시 기판 바이어스전압의 영향 (The Effects of Substrate Bias Voltage on the Formation of $(ZnS)_{1-x}-(SiO_2)_x$ Protective Films in Phase Change Optical Disk by R.F. Sputtering Method.)

  • 이태윤;김도훈
    • 한국재료학회지
    • /
    • 제8권10호
    • /
    • pp.961-968
    • /
    • 1998
  • 상변화형 광디스크의 보호막으로 사용되는 $ZnS-SiO_2$ 유전체막을 RF magnetron 스퍼트링방법에 의하여 제조하는 경우에 기판 바이어스전압의 영향을 조사하기 위하여, 알곤가스 분위기에서 ZnS(80mol%)-$SiO_2$(20mol%)타겟을 사용하여 Si Wafer와 Corning flass 위에 박막을 증착시켰다. 본 실험에서는 여러 실험 변수를 효과적으로 조절하면서 실험의 양을 줄이고 도시의 산포를 동시에 만족시키는 최적조건으로 타겟 RF 출력 200W, 기판 RF 출력 20W, 아르곤 압력 5mTorr과 증착시간 20분을 얻을 수 있었으며, 신뢰구간 95%에서 확인실험을 수행하였다. 증착된 박막의 열적 저항성을 측정하기 위해 $300^{\circ}C$$600^{\circ}C$에서 열처리시험을 수행하였고, Spectroscopic Ellipsometry 측정을 통한 광학적 데이터를 바탕으로 Bruggeman EMA(Effective Medium Approximation)방법을 이용하여 기공(void)분률을 측정하였다. 본 연구결과에 의하면 특성치 굴절률에 대하여 기판 바이어스인자와 증착시간 사이에는 서로 교호작용이 강하게 존재함을 확인할 수 있었다. TEM분석과 XRD 분석 결과에 의하면 기판 바이어스를 가한 최적조건에서 증착된 미세조직은 기존의 바이어스를 가하지 않을 조건에서 증착시킨 박막보다 미세한 구조를 가지며, 또한 과도한 바이어스전압은 결정구조의 조대화를 야기시켰다. 그리고 적절한 바이어스전압은 박막의 밀도를 증가시키며, 기공분률을 약 3.7%정도 감소시킴을 확인할 수 있었다.

  • PDF

노화에 의해 저하된 시공간 주의배분능력이 정서지각 편향성에 미치는 영향 (The Influences of Deteriorated Visuo-spatial Attention Allocation Ability Caused by Aging on Emotional Perception Bias)

  • 김상엽;정재범;남기춘
    • 감성과학
    • /
    • 제23권4호
    • /
    • pp.3-20
    • /
    • 2020
  • 본 연구의 목적은 노화에 따라 나타나는 시공간 주의배분능력과 정서지각 편향성의 변화에 대해 탐구하는 것이다. 본 연구에서는 시공간 주의배분능력을 측정하기 위해 useful field of view (UFOV) 과제와 정서지각 편향성을 측정하기 위해 정서지각과제(emotional perception task)를 사용하였다. 본 연구에는 노인 집단의 23명과 청년 집단의 25명의 총 48명의 실험참가자가 참여하였다. 실험 결과, UFOV 과제에서는 노인 집단이 청년 집단에 비해 느린 반응속도와 낮은 정답률을 보여 노인 집단이 청년 집단보다 저하된 시공간 주의배분능력을 가지고 있다는 것을 나타냈다. 또한, 정서지각과제에서는 노인 집단이 청년 집단에 비해 긍정적 정서지각 편향성과 부정적 정서지각 편향성 모두 크게 나타났다. 상관분석 결과에서는 정서지각과제의 정답률에 대한 부정적 정서지각 편향성이 UFOV 과제의 시야각 30° 조건의 반응속도와 유의미한 정적 상관관계가 나타났다(r=.289). 또한, 정서지각과제의 정답률에 대한 긍정적 정서지각 편향성은 UFOV 과제의 모든 시야각 조건들의 정답률과 유의미한 정적 상관관계가 나타났으며(r=.305, r=.322, r=.299), 반응속도와 유의미한 부적 상관관계가 나타났다(r=-.345, r=-.295, r=-.308). 이러한 결과는 노화가 저하된 시공간 주의배분능력 그리고 긍정적 정서지각 편향성과 부정적 정서지각 편향성의 증가와 관련있다는 것을 의미하고, 노화에 따라 나타나는 긍정적 및 부정적 정서지각 편향성은 저하된 시공간 주의배분능력과 관련성이 있는 것으로 여겨진다.

쇄석다짐말뚝의 극한지지력 데이터베이스 구축 및 통계학적 분석 (Constructing Database and Probabilistic Analysis for Ultimate Bearing Capacity of Aggregate Pier)

  • 박준모;김범주;장연수
    • 한국지반공학회논문집
    • /
    • 제30권8호
    • /
    • pp.25-37
    • /
    • 2014
  • 국내 외 하중저항계수설계법의 저항계수 보정 시 수집된 데이터베이스의 신뢰성을 향상시키기 위하여 저항편향계수 산정 단계에서 저항편향치의 ${\pm}2{\sigma}$ 범위의 데이터만을 선택하거나 가정된 확률분포 검정을 만족하도록 꼬리(tail)부분의 데이터를 제거하는 방법을 적용하고 있다. 그러나 이들 방법에서는 데이터베이스 내에 우연히 포함된 저품질의 데이터를 확인할 수 없는 단점이 발견되었다. 본 연구에서는 정재하시험의 품질, 원지반의 공학적 특성, 쇄석다짐말뚝의 제원 등의 품질기준을 이용하여 데이터베이스 구축 단계에서 수행할 수 있는 품질평가법을 제안하였으며, 국내 외 문헌 및 정재하시험 보고서로부터 65개소의 정재하시험 데이터를 수집하여 데이터베이스의 구축 및 품질평가를 수행하였다. 데이터베이스의 품질 평가 상태에 따른 저항편향계수와 변동계수, 저항계수를 비교한 결과, 기존의 데이터베이스 처리과정과 품질평가법을 병행할 경우에 저항편향계수의 불확실성이 감소되며, 신뢰도 높은 LRFD 저항계수 보정에 효과적인 것으로 판단된다.

플라스틱 기어의 트라이볼로지적 특성 향상을 위한 DLC 코팅 적용 (Evaluation of Tribological Characteristics of Diamond-Like Carbon (DLC) Coated Plastic Gear)

  • 배수민;마디 카뎀;서국진;김대은
    • Tribology and Lubricants
    • /
    • 제35권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Demand for plastic gears are increasing in many industries due to their low production cost, light weight, applicability without lubricant, corrosion resistance and high resilience. Despite these benefits, utilizing plastic gears is limited due to their poor material properties. In this work, DLC coating was applied to improve the tribological properties of polyamide66 gear. 0 V, 40 V, and 70 V of negative bias voltages were selected as a deposition parameter in DC magnetron sputtering system. Pin-on-disk experiment was performed in order to investigate the wear characteristics of the gears. The results of the pin-on-disk experiment showed that DLC coated polyamide66 with 40 V of negative bias voltage had the lowest friction coefficient value (0.134) and DLC coated PA66 with 0 V of negative bias voltage showed the best wear resistance ($9.83{\times}10^{-10}mm^3/N{\cdot}mm$) among all the specimens. Based on these results, durability tests were conducted for DLC coated polyamide66 gears with 0 V of negative bias voltage. The tests showed that the temperature of the uncoated polyamide66 gear increased to about $37^{\circ}C$ while the DLC coated gear saturated at about $25^{\circ}C$. Also, the power transmission efficiency of the DLC coated gear increased by about 6% compared to those without coating. Weight loss of the polyamide66 gears were reduced by about 73%.