• Title/Summary/Keyword: radiological science

Search Result 3,972, Processing Time 0.029 seconds

Clinical Value of Cardiovascular Calcifications on Non-Enhanced, Non-ECG-Gated Chest CT (비 조영증강 비 심전도동기 흉부 CT에서 발견되는 심혈관계 석회화의 임상적 가치)

  • Tae Seop Choi;Hwan Seok Yong;Cherry Kim;Young Joo Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.324-336
    • /
    • 2020
  • Cardiovascular calcifications can occur in various cardiovascular diseases and can serve as a biomarker for cardiovascular event prediction. Advances in CT have enabled evaluation of calcifications in cardiovascular structures not only on ECG-gated CT but also on non-ECG-gated CT. Therefore, many studies have been conducted on the clinical relevance of cardiovascular calcifications in patients. In this study, we divided cardiovascular calcifications into three classes, i.e., coronary artery, thoracic aorta, and cardiac valve calcifications, which are closely associated with cardiovascular events. Further, we briefly described pericardial calcifications, which can be found incidentally. Since the start of lung cancer screening in Korea in the second half of 2019, the number of non-enhanced, non-ECG-gated, low-dose chest CT has been increasing, and the number of incidentally found cardiovascular calcifications has also been increasing. Therefore, understanding the relevance of cardiovascular calcifications on non-enhanced, non-ECG-gated, low-dose chest CT and their proper reporting are important for radiologists.

Monte Carlo Simulation of Absorbed Energy by Gold Nano-Particles for Proton (양성자에 대한 금 나노입자의 밀도에 따른 흡수 에너지의 몬테카를로 전산모사)

  • Kwon Su Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Proton therapy is known for its superior treatment method due to Bragg peak. To enhance the therapeutic effects of protons, research has been conducted on distributing gold nanoparticles within tumors to increase the absorbed dose. While previous studies focused on handling gold nanoparticles at micrometer and nonometer scale, this study proposes a method to computationally estimate the effect of gold nanoparticles at the millimeter scale. The Geant4 toolkit was applied to computational modeling. Assuming a uniform distribution of water, similar to the human body, and gold nanoparticles, the concentration of gold nanoparticles was adjusted using density ratios. When the density ratio was 5%, the gain in absorbed energy due to gold nanoparticles was nearly twice that of the pure water phantom at the Bragg peak. As the density ratio increased, the gain in absorbed energy linearly increased. When gold nanoparticles were distributed in only one voxel at the Bragg peak, the energy of the protons affected only the neighboring voxels. However, in cases where gold nanoparticles were distributed over a wide area, the volume showing 95% of the maximum absorbed energy (9.46 keV) for the pure water phantom (9.95 keV) exhibited an improvement in absorbed energy over a region 16 times larger, and this region increased as the density ratio increased. Further research is needed to quantify the relationship between the density ratio of gold nanoparticles and the relative biological effect (RBE) in the millimeter scale.

Evaluation of Validity Thyroid Scintigraphy Using Parallel Hole Collimator (갑상샘 신티그래피 검사 시 평행다공형 조준기 적용의 유효성 평가)

  • Su-Young Park;Ji-Youn Kim;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • In this study, When acquisition thyroid scintigraphy images, a parallel hole collimator was applied, and the difference from the pinhole collimator was quantitatively analyzed under each image acquisition condition. Visual size, resolution, sensitivity, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were evaluated using thyroid phantom and point source. When comparing visual size, it was confirmed that an image similar to the size of the pinhole collimator could be obtained only when a magnification ratio of about 2.00 to 2.09 times when applying a parallel hole collimator. There was no tendency in FWHM(mm) measurement using a point source, and sensitivity was high in the parallel hole collimator. SNR and CNR were high when using a low magnification ratio, matrix size of 128×128, and a parallel hole collimator. In images of similar size to the naked eye, when the matrix size was the same, both SNR and CNR were high in the pinhole collimator. Therefore, when performing a thyroid scintigraphy test, if appropriate conditions are set according to the situation of each hospital and a parallel hole collimator is applied, it can be a good option in terms of equipment utilization and work efficiency.

Variability of Transrectal Shear Wave Elastography in a Phantom Model (팬텀연구에서 경직장 전단파탄성초음파의 가변성)

  • Jihyun Lee;Seong Kuk Yoon;Jin Han Cho;Hee Jin Kwon;Dong Won Kim;Jun Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1110-1122
    • /
    • 2023
  • Purpose This study aimed to assess the variability of transrectal shear wave elastography (SWE) using a designed phantom. Materials and Methods In a phantom, the SWE values were examined by two radiologists using agarose and emulsion silicone of different sizes (1, 2, and 3 cm) and shapes (round, cubic) at three depths (1, 2, and 3 cm), two region of interest (ROI) and locations (central, peripheral) using two ultrasound machines (A, B from different vendors). Variability was evaluated using the coefficient of variation (CV). Results The CVs decreased with increasing phantom size. Significant changes in SWE values included; agarose phantom at 3 cm depth (p < 0.001; machine A), 1 cm depth (p = 0.01; machine B), emulsion silicone at 2 cm depth (p = 0.047, p = 0.020; both machines). The CVs increased with increasing depth. Significant changes in SWE values included; 1 cm agarose (p = 0.037, p = 0.021; both machines) and 2 cm agarose phantom (p = 0.047; machine A). Significant differences in SWE values were observed between the shapes for emulsion silicone phantom (p = 0.032; machines A) and between ROI locations on machine B (p ≤ 0.001). The SWE values differed significantly between the two machines (p < 0.05). The intra-/inter-operator agreements were excellent (intraclass correlation coefficient > 0.9). Conclusion The phantom size, depth, and different machines affected the variability of transrectal SWE.

Development Plan for the Consequence Management in Response to Large-Scale Wildfire Disasters Using Air Force Transport Aircraft (C-130) (공군 수송기(C-130)를 활용한 대형산불 재난 대응 시 사후관리(CM) 발전방안)

  • Sangduk Kim;Minki Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.232-243
    • /
    • 2024
  • Purpose: Recently, large-scale forest fires caused by climate change, natural disasters, and human factors have been increasing every year in the East Coast and Taebaek Mountains region. Although forest fire extinguishing using helicopters is currently increasing, the need to introduce air force transport aircraft has continued to be raised due to the importance of early fire extinguishment to respond to large forest fires and the difficulty of extinguishing forest fires between sheep. This study seeks to present a plan for developing a post-fire management system for several aspects - achieving operational objectives, overcoming the operating environment, selecting a staging area, and efficient operation measures - to efficiently perform forest fire extinguishing missions using Air Force transport aircraft. Method: Based on literature research on forest fire extinguishing, forest fire extinguishing experiments using fixed-wing aircraft, and the operation status and operation method of forest fire extinguishing helicopters, the pros and cons of helicopter operation and the effects of large forest fire extinguishing using a large transport aircraft (C-130) Analyze the effectiveness of operation through analysis. Results: When extinguishing a large forest fire, an effective CM (Consequence Management) application plan was derived, including effective operation, control, command system, dispatch request, and forest fire extinguishment when integrating helicopter and fixed-wing aircraft (C-130). Conclusion: The application of the concept of CM (Consequence Management) is partially applied to some areas of chemical, biological, and radiological (CBRNE) protection in Korea, but efficient operation, control, and command systems are established when integrated operation of helicopters and large aircraft (C-130) in forest fire extinguishment. the concept of CM (Consequence Management), which is operated in advanced countries, was applied for safety management, dispatch requests, and forest fire extinguishing, thereby contributing to the establishment of a more advanced disaster and post-disaster management system.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

Perception and Satisfaction on Nutrition Counseling Service for Patients Consuming a Therapeutic Diet at Hospitals in Busan (부산지역 일부병원 치료식 섭취 환자의 영양상담에 대한 인식 및 만족도)

  • Yi, Jeong-Ryeh;Son, Eun-Joo;Lyu, Eun-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.9
    • /
    • pp.1305-1312
    • /
    • 2010
  • The purpose of this study was to investigate the perception and satisfaction on the nutrition counseling service for patients consuming a therapeutic diet at hospitals in Busan. The subjects were 153 inpatients at five hospitals with over 400 beds each. The research was performed through the interviewing process using questionnaires conducted from January to February, 2008. In a total of 88 patients, 57.5% had experienced nutrition counseling and were through the motives of counseling with doctors 64.2% and themselves 29.3% of the patients. In the method of nutrition counseling, 58% of the patients had an individual counseling. In the patients' perception on the nutrition counseling, 75.0% of the patients understood very well, 83.0% of them perceived the explanation as very important, 79.5% were very satisfied and 78.7% were helped in nutrition-management. On a scale of 5.00 for the nutrition counseling satisfaction, the average scores were 3.80 for 'explanation of knowledge', 3.71 for 'cognitive communication skills', 4.05 for 'effective communication skills' and 3.60 for 'facilitation skills'. The items of low scores in the nutrition counseling satisfaction were 'follow up diet-therapy after discharge', 'providing to personalized nutrition information', 'presentation of specific menu' and 'methods of menu planning'. There were significant (p<0.01) positive correlation between perception and satisfaction on the nutrition counseling. Therefore, it was suggested that dietitians increase the patients' satisfaction on the nutrition counseling with developing the model based on the patient-centered counseling.

The Perception of Aseptic Foods in Cancer Patients (멸균식 개발에 대한 암환자의 인식조사)

  • Lee, Kyung-A;Son, Eun-Joo;Song, Beom-Seok;Kim, Jae-Hun;Lee, Ju-Woon;Lyu, Eun-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.2
    • /
    • pp.203-211
    • /
    • 2013
  • The purpose of this study was to investigate the perception of aseptic foods (sterilized foods with radiation technology) in cancer patients in Busan. The subjects were 192 cancer patients at a hospital. This study was performed through interviews using questionnaires. Patients had perception scores on the need to develop aseptic foods (4.30 points out of 5.00), use aspetic foods (4.06/5.00), and intake aseptic foods (4.04/5.00). Patients less than 59 years old had significantly higher perception scores than those over 60 years old (p<0.05). The scores on aseptic food indicated the importance of various factors, including sanitation (4.86/5.00), good materials (4.82/5.00), nutritional value (4.79/5.00), unused of monosodium glutamate (MSG) (4.66/5.00), taste (4.61/5.00), and reasonable prices (4.60/5.00). The patients who were college graduates showed significantly higher scores and importance in good materials, proper packaging unit, simple cooking methods, food diversity, and familiar foods (p<0.05). In the aseptic menu items, patients wanted to include seasoned raw vegetables (4.11/5.00), a set menu (including cooked grain, soup, and a side dish) (4.08/5.00), seasoned cooked vegetables (4.04/5.00), low sodium kimchi (3.98/5.00), and fermented sauces (3.92/5.00). The patients with gastrointestinal cancer and other cancers (e.g. breast, thyroid, and renal cancer) had significantly higher necessity scores than lung patients for stew, seasoned raw vegetables, salad, low sodium kimchi, and a set menu (p<0.05).

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

Development and Application of Training Program for RI-Biomics Manpower through Analysis of Educational Demands (교육수요 분석을 통한 RI-Biomics 전문인력 양성 프로그램 개발 및 적용)

  • Shin, Woo-Ho;Park, Tai-Jin;Yeom, Yu-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.1
    • /
    • pp.159-167
    • /
    • 2015
  • RI-Biomics is a promising radiation convergence technology that combines radiation with bio science as new growth power technology. Many developed countries are focusing active support and constant exertion to dominate the RI-Biomics market in advance. In order to achieve global leadership in the RI-Biomics field, we need more highly advanced technologies and professional manpower. In fact, we have less manpower compared to technology we currently hold. In this study, we established a basic infrastructure to train professional manpower in the RI-Biomics field by developing/operating optimum training program through expert interviews and survey. The developed program has four organized sections to understand overall procedure of RI-Biomics. To evaluate our training program, we performed test operations with eight students who have a major related to RI-Biomics for three weeks in KARA (Seoul) and KAERI (Jung-eup). In detail, radioisotope usage and safety management were conducted for one week as basic course, RI-Biomics application technology was conducted for two weeks as professional course. To verify performance results of training program, we conducted to journal research, daily reports, and survey on participants. The results show a high level of satisfaction with training programs and continuous intention of involvement in our program. We also need to develop an intensive course to train high-quality human resources and to operate training program continuously. This training program will be used as basic materials for the development of RI-Biomics curriculum for university. Hence, we will expect that our training program contributes in training a professional manpower and develop RI-Biomics technology.