• Title/Summary/Keyword: quartz crystal microbalance(QCM)

Search Result 93, Processing Time 0.023 seconds

Development of a hygroscopic polymer-coated QCM humidity sensor and its characteristics (감습 고분자막이 코팅된 수정미소저울 습도센서 제작 및 특성연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il;Nham, Hyun-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.395-401
    • /
    • 2005
  • A highly stable quartz crystal microbalance (QCM) that showed a stability of frequencies and exhibited a very low noise level has been developed. The long-term drift was <0.05 Hz/h over a period of 10 h, and the short-term rms (root mean square) noise was <0.015 Hz. Our QCM sensor was used as a humidity sensor employing a poly(methyl methacrylate) (PMMA) polymer film as a hygroscopic layer, which showed good characteristics in the relative humidity (RH) range of $2{\sim}90%$ RH. Comparing the characteristics of the QCM sensor with those of other types of humidity sensors employing PMMA film as a hygroscopic layer, and with other QCM sensors employing other hygroscopic layers is represented.

Determining the Self-Assembly and Redox Process of a Viologen Monolayer by Electrochemical Quartz Crystal Microbalance (수정진동자를 이용한 Viologen 단분자막의 자기조립화와 산화,환원 반응 측정)

  • Ock, J.Y.;Song, S.H.;Shin, H.K.;Chang, J.S.;Chang, S.M.;Kwon, Y.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.23-27
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency$({\Delta}F)$ and resonant resistance(R). The redox process of viologen was observed with resonant frequency $({\Delta}F)$.

  • PDF

수정진동자를 이용한 Au 표면에서 avidin-biotin 결합 리포좀 막의 구조 분석

  • Park, Jong-Won;Han, Seong-Ung;Gwon, Jeong-Hun;Park, Jin-Yeong;Jo, Hong-Sik;Lee, Haeng-Ja;Jang, Sang-Mok
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.546-549
    • /
    • 2000
  • Liposomes and proteoliposomes, artificial membranes, can interact with many solutes, such as drugs, peptides and proteins. Immobilization of (proteo)liposomes as supramolecular aggregates on gold surfaces have potential applications in nanotechnology and biosensors. We demonstrate a quartz crystal analyzer (QCA) method to monitor the construction of multi layers of unilamellar liposomes based on avidin-biotin binding on gold surface using quartz crystal microbalance(QCM). Thus, QCA provides an on line and efficient method to detect the protein membranes construction and have applications to biosensing system.

  • PDF

대장균 검출을 위한 항체고정화 Quartz Crystal Microbalance 시스템의 특성

  • Park, In-Seon;Kim, Nam-Su
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.701-702
    • /
    • 2000
  • The thiolated anti-Escherichia coli antibody prepared by thiolation with a thiolcleavable heterobifunctional cross-linker, sulfosuccinimidyl 6[3- (2-pyridyldithio) propionamido]hexanoate (sulfo-LC-SPDP) was chemisorped onto one gold electrode of the piezoelectric quartz crystal surface. In the QCM system employing a batch-type well holder, a steady-state frequency decrease was attained within 20 min when $100{\sim}200\;{\mu}L$ suspensions of Escherichia coli having viable cell counts of $10^5{\sim}10^6\;CFU/mL$ were added. The stability of sensor response was improved compared to the system with a batch-type dip holder.

  • PDF

Development of Olfactory Biosensor Using Olfactory Receptor Proteins Expressed in E. coli

  • Seong, Jong-Hwan;Go, Hwi-Jin;Park, Tae-Hyeon
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.639-642
    • /
    • 2003
  • Olfactory receptor protein ODR10 was expressed in E.coli as fusion protein with GST and His6 Tag. Crude membrane extract of the expressed protein was coated on the surface of quartz crystal microbalance, and the interaction of the ODR10 with several odorants was examined. Although the expression level was very low, quartz crystal microbalance showed that the expressed protein interacted most strongly with diacetyl (butanedione), which is known to bind to the ODR10 protein selectively. The interaction between ODR10 and diacetyl was $5{\sim}10$ times stronger than the interaction between ODR10 and other odorants. Thus, E. coli cells expressing the olfactory receptor protein could be used as an olfactory biosensor. Also, such system could be used to test which olfactory receptor reacts specifically with which odorant molecules, since there has been no cheap and convenient way to test the interaction of olfactory receptors and odorant molecules yet.

  • PDF

Fabrication of an Alternating Multilayer Film of Poly(ethylene-alt-maleic anhydride) and Poly(4-vinyl pyridine) by Layer-by-Layer Self-Assembly Method (Layer-by-Layer 자기조립법에 의한 Poly(ethyiene-alt-maleic anhydride)i Poly(4-vinyl pyrtdine) 다층막 제조)

  • Lee Joon Youl;Hong Sook-Young
    • Polymer(Korea)
    • /
    • v.29 no.4
    • /
    • pp.392-398
    • /
    • 2005
  • Self-assembled multilayer thin films of poly(ethylene-alt-maleic anhydride) (PEMAh) and poly(4-vinyl pyridine) (P4VP) were fabricated by layer-by-layer (LbL) sequential adsorption. Fourier transform infrared (FT-IR) spectroscopic analysis of the self-assembled PEMAh/P4VP multilayer films confirms that the driving forces for the multilayer buildup are the intermolecular hydrogen bonding and electrostatic interactions. The linear increase of absorption peak of P4VP at 256 nm with increasing number of PEMAh/P4VP bilayers indicates that the multilayer buildup is an uniform assembling process. We also investigate the effects of polyelectrolyte concenhation variation of the dipping solution and pH variation of the PEMAh solution on the multilayer film formation. Thickness. adsorbed polyelectrolyte mass and surface roughness of the multilayer films were measured by UV-visible spectroscopy, quartz crystal microbalance (QCM), and atomic force microscopy (AFM), respectively.

In-situ monitoring technique for deposition process of CdS buffer layer for CIGS thin film solar cells (CIGS 박막 태양전지용 CdS 버퍼층 제조 공정의 in-situ 모니터링 기술)

  • Kown, Young-Jun;Ahn, Se-Jin;Yoon, Jae-Ho;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.434-435
    • /
    • 2008
  • An in-situ monitoring technique for deposition process of CdS buffer layer was developed in this work. A quartz crystal microbalance (QCM) was used to measure the frequency change during the CdS deposition process and the relation ship between frequency change and film thickness and optical transmittance was investigated. The film thickness shows a linear relationship with frequency change, demonstrating that frequency change measured by QCM can be used a in-situ monitoring tool for CdS deposition process.

  • PDF

Suppression of silicon clusters using a grid mesh under DC bias

  • Kim, Yonwon;Kang, Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.146-149
    • /
    • 2017
  • Si clusters generated during the plasma chemical vapor deposition (CVD) process have a great influence on the quality of the fabricated films. In particular, in hydrogenated amorphous silicon thin films (a-Si:H) used for thin film solar cells, Si clusters are mainly responsible for light-induced degradation. In this study, we investigated the amount of clusters incorporated into thin films using a quartz crystal microbalance (QCM) and specially designed cluster eliminating filters, and investigated the effect of the DC grid mesh in preventing cluster incorporation. Experimental results showed that as the applied voltage of the grid mesh, which is placed between the electrode and the QCM, decreased, the number of clusters incorporated into the film decreased. This is due to the electrostatic force from the grid mesh bias, and this method is expected to contribute to the fabrication of high-quality thin films by preventing Si cluster incorporation.

Study on Electrochemical Property of Self-Assembled Viologen Monolayers Using Electrochemical Quartz Crystal Microbalance (EQCM) Method (EQCM법을 이용한 자기조립된 Viologen 단분자막의 전기화학적 특성 연구)

  • Lee, Dong-Yun;Park, Sang-Hyun;Park, Jae-Chul;Kwon, Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.107-110
    • /
    • 2006
  • We fabricated the monolayers onto QCM by self-assembly using viologen, which has been widely used as electron acceptor. A gold electrode of the QCM was cleaned by piranha solution and prepared the ethanol-acetonitrile(1:1) solution with 2 m mol/l viololgen compounding of pure hi gas. We determined the time dependence to resonant frequency shift during self-assembly process and the electrochemical behavior of the self-assembled viologen monolayers by cyclic voltammetry. With increasing scan rate, the redox peak current of the viologen increased linearly. This was signified that the redox reaction was reversible. The EQCM measurements revealed the anions transfer during redox reactions, respectively. From the EQCM data, the well-defined shape peaks were nearly equal charges by cyclic voltammetry.

Electrochemical Properties of Viologen Self-Assembly Monolayer Using QCM (수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성)

  • 옥진영;신훈규;박재철;장정수;권영수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.496-500
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface[1]. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency(ΔF) and resonant resistance(R). The redox process of viologen was observed with resonant frequency(ΔF).