• Title/Summary/Keyword: push factor

Search Result 126, Processing Time 0.022 seconds

Experimental and Analytical studies on Failure Behavior of Stud Shear Connectors in CFT Structures (CFT 구조에 적용된 스터드 전단연결재의 파괴 거동에 대한 실험 및 해석적 연구)

  • Lee, Sangyoon
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.400-412
    • /
    • 2013
  • For the composite behavior of steel tube and inner concrete, the shear connectors should be applied to the CFT structures. However, the present design codes don't provide the design criteria that can be applied on shear connectors in the CFT structures typically filled with plain concrete. This study has been carried out to propose design criteria (shear strength and resistance factor) for the stud shear connectors in CFT structures. Experimental tests using the push-out specimens with the plain concrete blocks and finite element analysis were conducted for the purpose of verifying the main failure mode to propose the shear strength of studs in CFT structures. From the results of this study, the main failure mode of studs in CFT structures is splitting crack of concrete and this failure mode reduces shear strength of studs in CFT structures relatively to those embedded in RC blocks.

An Experimental Study on Longitudinal Shear Capacity of Composite Slab Embedded with Silence Insulator (방음재를 삽입한 합성슬래브의 수평전단성능에 관한 실험적 연구)

  • Lee, Seon-Keun;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.64-71
    • /
    • 2018
  • This paper provides the results for experimental study on longitudinal shear performance for new-concept composite slabs embedded with silence insulator. Longitudinal shear capacity tests are used to predict characteristics of composite action between the concrete block, silence insulator and deckplate. A total set of 7 Push-Down specimens are tested to clarify the composite action between the concrete block, silence insulator and deckplate. Parameters in this study are the width of T-type bar, the depth of reinforced bar and the thickness of silence insulator. The results from experimental study on longitudinal shear capacity for new-concept composite slabs applied T-type bar, Reinforced bar and Silence insulator are summarized as follows. In test result, the Longitudinal Shear Capacity of the new concept specimen is 2 times excellent than basic specimen with safety. It is expected that applying the proposed composite slab detail at the actual site will provide a significant safety factor in structural aspect of the existing composite slab, and greatly contribute to the improvement capacities of resisting vibration and sound.

Waste Elimination in Construction Process using Value Stream Analysis - Focused on Waste Elimination of Re-bar Works (가치흐름 분석을 통한 건설프로세스의 낭비제거 방안)

  • Mun Jeong-Mun;Kim Chang-Duk;Park Dong-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.416-421
    • /
    • 2001
  • The domestic reinforcement concrete works have mainly worked the process of re-bar fabrication/assembly on site and re-bar works affected by structural safety, durability, and schedule with form work. Accordingly, This study analyzes the process of re-bar fabrication/assembly on site to apply lean production principles to construction Value Stream Analysis(VSA) is analyzed into value-adding activity and non-value-adding activity on construction process through value analysis and Value Stream Mapping(VSM). In the results, non-value-adding activity generates waste such as the activity steps, labors, equipments, materials, time, and so on. Additionally, push-driven production is investigated making low productivity from the overproduction and so on. To resolve the problems in the process, The purpose of this paper eliminates waste factor through maximizing the value-adding activity generating value added and minimizing non-value adding activity. Particularly, it makes flow production and pull-driven production through minimizing work-in-process(WIP ).

  • PDF

Seismic Performance Evaluation of Steel Moment Frames in Korea Using Nonlinear Dynamic Analysis (비선형동적해석을 통한 국내 철골 모멘트골조의 내진성능 평가)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • Domestic steel moment resisting frames were designed in accordance with the former KBC2005 and the current KBC2009, and then their seismic performance was evaluated in accordance with FEMA355F by utilizing nonlinear dynamic analysis. The results from the procedure in FEMA355F were different with those from the capacity spectrum method utilizing nonlinear static push-over analysis. In particular, the domestic steel moment resisting frames have a weak panel zone, so their behavior can be estimated more precisely by nonlinear dynamic analysis. The domestic steel moment resisting frames satisfied the performance goal if located at a site class $S_B$ or $S_C$, regardless of the story number and the response modification factor. However, if they are located at a site class $S_D$ or $S_E$, performance goal satisfaction cannot be guaranteed. No matter what standard is used for the design, KBC2005 or KBC2009, the domestic steel moment resisting frames may possess satisfactory seismic performance if the site condition is relatively good.

Static Test and Suggestion of Shear Strength Equation on Shear Studs in Composite Bridge (합성형 교량에서 전단연결재에 대한 정적실험 및 강도식의 제안)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2018
  • In this study, to investigate the shear connection material for the composite of steel plate and bottom plate, design standards and research cases for shear connectors in various countries around the world were analyzed and shear tests were performed on the Push-out specimens with a shear connection, which transmits the horizontal shear force developed on the contact surface between the steel plate and the concrete slab due to various vertical loads acting on the bridge deck. Through Push-out tests of shear studs, of which FRP bar instead reinforcement is placed, the shear stud evaluation formula of the steel strap bottom plate was suggested. The suggested equation suggested in this study has the safety factor of approximately three times compared to allowable strength of highway bridge design criteria. In addition, compared to existing DIN standards and Viest assessment equation, the results showed similar values(approximately, 5% error).

푸시기반 CORBA 트레이더 서비스 구현

  • Yu, Jae-Jeong;Yun, Beom-Ryeol;Kim, Su-Dong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.6 no.1
    • /
    • pp.68-81
    • /
    • 2000
  • CORBA Trader Service is to locate appropriate objects that provide the desired functionality at runtime. To provide this service, the Trader Service federates a local trader and remote traders by considering the Traders or Link policies, and it returns the service offers that are requested by the importer. This traditional way of trading reveals a performance problem due to the low response time. The response time largely depends on the amounts of service offers of the Importer's request and the frequency of federations with the other trader. The performance is a key factor for evaluating the Trader Service performance.In order to overcome the low response time and to provide the high-quality services, we propose new policies of Import and Trader, and present a PUTS(Push Trader Service) model which implements this new advanced trader service. We present the design and implementation of the PUTS's major modules, also make a comparison between PUTS system and traditional trader system in terms of performance and functionality through case studies.

  • PDF

Static Tensile Strength Evaluation of Notched Coeposite Materials (노치를 갖는 복합재료의 정적강도평가(I))

  • 김윤해;김영식;서곡홍신
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.19-29
    • /
    • 1993
  • The static tensile tests of GFRP, ID300, CFRID300 and CFRPEEK were made on the plain and notched specimens at room temperature. The results were discussed based on linear notch mechanics which was proposed by H.Nistani. The fracture of notched GFRP, ID300, CFRID300 and CFRPEEK specimens is controlled by the elastic maximum stress, $({\sigma}_max)$, and the notch root racius,$\rho$, alone, independently of the other geometrical conditions. The relation between fracture nominal stress,$({\sigma}_max)$, and stress concentration factor, $K_t$ and a part where $({\sigma}_c)$ is nearly constant independent of $K_t$. A similar phenomenon can be seen in the fatigue tests of notched specimes under rotating bending or push-pull. The almost constant $({\sigma}_c)$ values correspond to the nearly constant apparent stress intensity factor, $K_{1pc}$ values, obtained by assuming ,$\rho$=0. This can be attributed to the existence of the stable crack. Linear notch mechanics is very useful for analyzing the static tensile fracture behavior of notched GFRP, ID300, CFRPEEK specimens.

  • PDF

Seismic Performance Evaluation of Freeform Diagrid System (비정형 Diagrid System의 내진성능 평가)

  • Ko, Chang-Kyun;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.189-198
    • /
    • 2011
  • Many new structural systems have been developed to build free-form structures, which is the new architectural trend for aesthetic beauty. The diagrid system resists both gravity and later loads, with its perimeter-diagonal columns. In the current seismic-design provisions, however, a seismic-performance factor for a new structural system has not yet been provided. ATC-63 provides a new methodology for defining various seismic-performance factors, including the response modification factor. In this paper, nonlinear static and dynamic analyses were conducted for the 3D diagrid frame, with each load applied at $0-180^{\circ}$ degrees. Through these analyses, the seismic performance of the diagrid system was evaluated.

Design for a Hybrid System of Integration Kanban with MRPII

  • Song, Tae-Yeng;Jung, Seong-Won;Cao, Cheng-Xuan;Park, Jin-Woo
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.280-287
    • /
    • 2001
  • There have been some studies about hybrid production system, which integrate push system and pull system. Most of them are based on the simple production system considering one product line. Though there are many studies about hybrid production system, it\`s not practical to implement them for real factory, because most of them did not consider various factors about real factory. On this study we designed hybrid production system considering some factor - one is automatic kanban generation, the other is dispatching rule for Multi-tasking worker, and the last one is the priority of kanban. At last, We give simulation results fur a real company, which produce various cameras in Korea.

  • PDF

Minimizing Leakage of Sequential Circuits through Flip-Flop Skewing and Technology Mapping

  • Heo, Se-Wan;Shin, Young-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.215-220
    • /
    • 2007
  • Leakage current of CMOS circuits has become a major factor in VLSI design these days. Although many circuit-level techniques have been developed, most of them require significant amount of designers' effort and are not aligned well with traditional VLSI design process. In this paper, we focus on technology mapping, which is one of the steps of logic synthesis when gates are selected from a particular library to implement a circuit. We take a radical approach to push the limit of technology mapping in its capability of suppressing leakage current: we use a probabilistic leakage (together with delay) as a cost function that drives the mapping; we consider pin reordering as one of options in the mapping; we increase the library size by employing gates with larger gate length; we employ a new flipflop that is specifically designed for low-leakage through selective increase of gate length. When all techniques are applied to several benchmark circuits, leakage saving of 46% on average is achieved with 45-nm predictive model, compared to the conventional technology mapping.