Abstract

In this study, to investigate the shear connection material for the composite of steel plate and bottom plate, design standards and research cases for shear connectors in various countries around the world were analyzed and shear tests were performed on the Push-out specimens with a shear connection, which transmits the horizontal shear force developed on the contact surface between the steel plate and the concrete slab due to various vertical loads acting on the bridge deck. Through Push-out tests of shear studs, of which FRP bar instead reinforcement is placed, the shear stud evaluation formula of the steel strap bottom plate was suggested. The suggested equation suggested in this study has the safety factor of approximately three times compared to allowable strength of highway bridge design criteria. In addition, compared to existing DIN standards and Viest assessment equation, the results showed similar values(approximately, 5% error).

본 연구에서는 강주형과 바닥판의 합성에 사용되는 전단연결재에 대한 연구를 위해 세계 각국에서 사용되는 설계기준과 연구사례를 분석하고 교량 바닥판에 작용하는 각종 수직하중으로 인해 강주형과 콘크리트 슬래브의 접촉면에 발생하는 수평방향의 전단력을 전달하는 이 연결재를 설치한 밀어내기 시험체에 대하여 전단실험을 수행하였으며, 이 시험을 통하여 철근 대신 FRP 철근이 배치된 Steel strap 바닥판의 전단열재 평가식을 제안하였다. 본 연구에서의 제안식은 도로교설계기준의 전단연결재 허용강도 대비 약 3배의 안전율을 가지고 있으며, 기존의 DIN 기준과 Viest 평가식과 비교하면 5%정도의 오차로 유사한 결과를 보여주었다.

Keywords

References

  1. DIN 18800-5 (2007), Steel Structures - Part 5: Composite Structures of Steel and Concrete - Design and Construction.
  2. Eurocode 4 (1997), Design of Composite Steel and Concrete Structures Part 2: Composite Bridges(ENV 1994-2).
  3. Hyun, B. H., Chung, C. H., Shim, C. S., and Ma, H. W. (2005), Design of Horizontal Shear Strength of the Shear Connectors Between Precast Decks and PSC Girders, Journal of the Korean Society of Civil Engineers, 25(2A), 327-335 (in Korean).
  4. Korea Expressway Corporation, DAEWOO Institute of Construction Technology (2001), A Study on the Development of New-type Composite Box-Girder Bridge, Research Report, No. 01-30 (in Korean).
  5. Korean Highway Bridge Design Code (2010) Section 2.1, Load, pp.6-9 (in Korean).
  6. Lee, P. G., Shim, C. S., and Yoon, T. Y. (2003), Static Behavior of Large Stud Shear Connectors, Korean Society of Steel Construction, 15(6), 611-620 (in Korean).
  7. Mattock, A. H., Li, W. K., and Wang, T. C. (1976), Shear Transfer in Lightweight Reinforced Concrete, PCI Journal, 21(1), 20-39. https://doi.org/10.15554/pcij.01011976.20.39
  8. Menkulasi, F. (2002), Horizontal Shear Connectors for Precast Prestressed Bridge Deck Panels, Virginia Polytechnic Institute and State University.
  9. Viest, I. M. (1956), Investigation of Stud Shear Connectors for Composite and Steel T-beam, Journal of ACI, 27(8), 875-891.