• Title/Summary/Keyword: pulse-energy

Search Result 1,319, Processing Time 0.035 seconds

A Study on the Microhole Machining Characteristics of the ${Al_2}{0_3}$ Ceramics using Excimer Laser (Excimer laser를 이용한 알루미나(${Al_2}{0_3}$) 세라믹의 미세구멍 가공 특성에 대한 연구)

  • 김병용;이건상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1072-1075
    • /
    • 2001
  • $Al_2O_3$ ceramics are generally used as components in processing equipment, devices or machinery because it can perform some functions better than competing metals or polymers. Many of these applications rely on $Al_2O_3$ ceramics special electromagnetic properties, its relative chemical inertness, hardness, strength and its temperature capabilities. But $Al_2O_3$ ceramics are brittle materials, a fact that may cause problems and at the same time be helpful while machining with laser. This study described a basic study of the input parameters effect on the dimension of the microhole at the $Al_2O_3$ ceramics using Excimer laser. In the laser microhole machining of $Al_2O_3$ ceramics, major input parameters are pulse energy, pulse power, pulse frequency and pulse numbers. In conclusion, we can get a smaller microhole and diameter rate by an appropriate pulse energy, pulse frequency and pulse number.

  • PDF

Ablation of Cr Thin Film on Glass Using Ultrashort Pulse Laser (극초단펄스 레이저에 의한 크롬박막 미세가공)

  • 김재구;신보성;장원석;최지연;장정원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.620-623
    • /
    • 2003
  • The material processing by using ultrashort pulse laser, in recently, is actively applying into the micro machining and nano-machining technology since ultrashort pulse has so faster than the time which the electrons energy absorbing photon energy is transmitted to surrounding lattice-phonon that it has many advantages in point of machining. The micro machining of metallic thin film on the plain glass is widely used in the fields such as mask repairing for semiconductor, fabrication of photonic crystal, MEMS devices and data storage devices. Therefore, it is important to secure the machining technology of the sub-micron size. In this research, we set up the machining system by using ultrashort pulse laser and conduct on the Cr 200nm thin film ablation experiments of spot and line with the variables such as energy, pulse number, speed, and so on. And we observed the characteristics of surrounding heat-affected zone and by-products appeared in critical energy density and higher energy density through SEM, and also examined the machining features between in He gas atmosphere which make pulse change minimized by nonlinear effect and in the air. Finally, the pit size of 0.8${\mu}{\textrm}{m}$ diameter and the line width of 1${\mu}{\textrm}{m}$ could be obtained.

  • PDF

Study on the Variation of Menstruating Women's Pulse Wave - In the Focus of Blood Circulation Index, Pulse Energy, Radial Augmentation Index - (여성의 월경(月經) 맥파(脈波) 특성 연구 - 혈액순환지수, 맥(脈)에너지, 혈관탄성계수를 중심으로 -)

  • Lee, Jeong Won;Kim, Yi Soon;Hong, Dong Kyun;Kim, Gyeong Cheol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.2
    • /
    • pp.246-252
    • /
    • 2013
  • A descriptive, comparative study was performed using female college students as experimental subjects. The primary objective was to compare the changes in pulse waves that take place during normalcy and during menstruation. The second objective was to compare the pulse waves of experimental subjects with severe menstrual pain and experimental subjects with minor or no menstrual pain during menstruation and during normalcy. The subjects of this experiment were female college students attending D University, located in Pusan, and the data were collected from September 2011 to February 2012. Their blood circulation index and pulse-wave factors were measured. During normalcy, these data were gauged a week to ten days after menstruation, and during menstruation, they were gauged two to three days after the start of menstruation, when the menstrual pain was at its peak. The results was as follows. In the characteristics of the blood circulation index, the index increased during menstruation, resulting in an increase in only the blood volume of the left ventricle. And the pulse energy of the left Chon, Kwan, Cheok and right Cheok were significantly higher during menstruation. Additionally, the average pulse energy in the left hand was distinctively lower in the menstrual group than in the normalcy group. There is a difference in blood pulse factors between normalcy and during menstruation, as well as a difference in blood pulse factors in experiment group without menstrual pain and experiment group with menstrual pain. These differences were particularly observed in the blood circulation index, pulse energy.

Simulation for Dose-Rate Latchup by Transient Radiation Pulse in CMOS Device (CMOS 소자에서 과도방사선펄스에 의한 Dose-Rate Latchup 모의실험)

  • Lee, Hyun-Jin;Lee, Nam-Ho;Hwang, Young-Gwan
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1185-1186
    • /
    • 2008
  • A nuclear explosion emits a transient radiation pulse like gamma rays. Gamma rays have a high energy and cause unexpected effects in semiconductor devices. These effects are mainly referred to dose-rate latcup and dose-rate upset. By transient radiation pulse in CMOS devices, dose-rate latchup is simulated in this paper.

  • PDF

The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors (가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성)

  • 이유수;정종한;정현주;김문환;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.

Performance Improvement of Flashlamp-Pumped Ti: sapphire Laser

  • Xia, Jinan;Lee, Min-Hee;Eur, Jeong-Pil
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.48-54
    • /
    • 2002
  • Experimental study is performed on flashlamp-pumped Ti: sapphire lasers with single, double, and four-partial-ellipse-pump cavities aiming at improving the performance of the lasers. The output energy of 604 mJ per pulse with a width of 25 $\mu$s at a total laser efficiency of 0.13% is achieved in the laser pumped by a light pulse of 45$\mu$s without a fluorescent converter The laser output energy versus its Ti: sappy ire rod length, pumping-light pulse duration, and electrical input energy are discussed with or without using a fluorescent converter. The result shows that much more output energy is obtained il a longer Ti: sapphire-rod laser pumped by a shorter light pulse when its output coupler has an optimized transmittance. In addition, an enhancement of output energy by a factor of 7 is achieved. in the laser using a fluorescent converter LD490.

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

The Impulse Output Characteristics using Cascading Method of Compact Transformer (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Joung, Jong-Han;Kim, Whi-Young;Hong, Jung-Hwan;Park, Koo-Ryul;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

The Real-Time Temporal and Spatial Diagnostics of Ultrashort High-Power Laser Pulses using an All-Reflective Single-Shot Autocorrelator

  • Kim, Ha-Na;Park, Seong Hee;Kim, Kyung Nam;Han, Byungheon;Shin, Jae Sung;Lee, Kitae;Cha, Yong-Ho;Jang, Kyu-Ha;Jeon, Min Yong;Miginsky, Sergei V.;Jeong, Young Uk;Vinokurov, Nikolay A.
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.382-387
    • /
    • 2014
  • An all-reflective, simple noncollinear second harmonic (SH) autocorrelator is described for monitoring the shot-to-shot behavior of ultrashort high-power laser pulses. Two mirrors are used for the dispersion-free splitting of a pulse into two halves. One of the mirrors is able to adjust the delay time and angle between two halves of the laser pulse in a nonlinear crystal. We present the possibility of real-time measurement of the pulse duration, peak intensity (or energy), and the pointing jitters of a laser pulse, by analyzing the spatial profile of the SH autocorrelation signal measured by a CCD camera. The measurement of the shot-to-shot variation of those parameters will be important for the detailed characterization of laser accelerated electrons or protons.

A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women (미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 -)

  • Seo, Chang-Woon;Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.