• Title/Summary/Keyword: pulse analysis

Search Result 2,098, Processing Time 0.032 seconds

Quantitative Analysis for Termites Damage of Wooden Heritage using Ultrasonic Pulse Velocity (초음파 전파속도법을 이용한 목조 문화유산 흰개미 피해의 정량 평가)

  • Ahn, Jae-Cheol
    • Journal of architectural history
    • /
    • v.24 no.5
    • /
    • pp.41-48
    • /
    • 2015
  • Quantitative analysis of termites damage is important in terms of conservation and maintenance of wooden cultural heritage buildings, because termites makes cavities and decreases the section area of wooden structural members. The purpose of this study is to forecast the range and spread of termites damage in the wooden structural members by using ultrasonic pulse velocity method. Ultrasonic pulse velocity has been used as one of non-destructive test to analysis the internal defect by using difference velocity between medium material and cavity. This method would be effective to analysis termites damages. From the result of the ultrasonic velocity test, the loss rate of area effected by termites damage had a strong correlation with ultrasonic velocity. And it is possible to predict the loss rate of area from by termites damage by using regression equation in the case of structural member of fine tree.

Determination of Sasang Constitution from Artery Pulse Waves (요골 맥파를 이용한 사상체질 판별)

  • Cho, Jae Kyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.359-365
    • /
    • 2020
  • Sasang Constitution data that were classified by the QSCCII (Questionnaire for the Sasang Constitution Classification II) and artery pulse waves of Chon, Guan, and Chuck data measured using an electronic manometer, were obtained from 732 subjects who visited an oriental hospital. The pulse width, peak height, and number of peaks were extracted from the pulse waves as feature variables. Validity and reliability analyses were performed to obtain the feature variables. The feature variables with high validity and reliability were selected as the discriminant variables. The pulse wave data were divided into training and predicting samples by applying a fivefold cross-validation technique. Discriminant analysis was performed for the training sample, and discriminant functions were obtained. The discriminant functions were applied to the predicting sample and the Sasang Constitution was predicted. The accuracy of prediction was estimated by comparing the predicted Sasang Constitution and that obtained by QSCCII. The accuracy of the predicted Sasang Constitution before (after) age and sex calibration was 73.6 % (70.4 %), 68.4 % (84.2 %), and 74.2 % (67.7 %) for Taeumin, Soumin, and Soyangin, respectively, and 72.5 % (73.8 %) in total.

Comparative study of dose due to the change of fluoroscopy pulse rate of Epidural Injection treatment time (Epidural Injection시술시 투시율 변화에 따른 선량비교연구)

  • Seo, Jeong-Beom;Oh, Dong-Hoon;Lee, Jeong-Beom;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.21-26
    • /
    • 2013
  • To be investigated and measures to reduce the medical exposure of patients to change the Epidural Injection time Fluoroscopy Pulse Rate in this study. Was conducted in 50 patients who underwent surgery Epidural Injection performed by interventional care of Konkuk University Hospital from January to April 2013. The treatment time with the change of Pulse rate, is measured in minutes fluoroscopy time, and measured the area dose (${\mu}Gym^2$) and depth dose (mGy). Using the Image J program, to measure the PSNR and SNR. The fluoroscopy time as a result surgery, there was no significance in the statistical analysis, and depth dose is 34.3 to 34.9%, was reduced from 35.8 to 38.7% the area dose. It is possible to reduce the appropriate Pulse rate, to reduce the dose without statistical analysis significance fluoroscopy time.

  • PDF

A Study of Active Pulse Classification Algorithm using Multi-label Convolutional Neural Networks (다중 레이블 콘볼루션 신경회로망을 이용한 능동펄스 식별 알고리즘 연구)

  • Kim, Guenhwan;Lee, Seokjin;Lee, Kyunkyung;Lee, Donghwa
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.4
    • /
    • pp.29-38
    • /
    • 2020
  • In this research, we proposed the active pulse classification algorithm using multi-label convolutional neural networks for active sonar system. The proposed algorithm has the advantage of being able to acquire the information of the active pulse at a time, unlike the existing single label-based algorithm, which has several neural network structures, and also has an advantage of simplifying the learning process. In order to verify the proposed algorithm, the neural network was trained using sea experimental data. As a result of the analysis, it was confirmed that the proposed algorithm converged, and through the analysis of the confusion matrix, it was confirmed that it has excellent active pulse classification performance.

Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis (맥진기술동향 조사를 통한 맥진기 개발방안 제안)

  • Lee, Yu-Jung;Lee, Jean;Kim, Jang-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

Propagation Characteristic Analysis of Square and Gaussian Pulse Signals on the Microstrip Line (구형 및 가우시안 펄스신호의 마이크로스트립 선로상 전파특성 해석)

  • Park, Sun-Kuen;kim, Nam;Rhee, Sung-Yup;Choi, Jung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.5
    • /
    • pp.384-394
    • /
    • 1996
  • The propagation properties of square and Gaussian pulse signals on the microstrip line are investigated by using proper conventional models to meet the frequency range of a pulse, accuracy, and geometrical requirements of the microstrip line. Numerical integration technique which has its accuracy and is easily simulated, is used to obtain the time domain response of pulse signals. The dispersion of pulse signals is analyzed regarding to the relative permittivity $\varepsilon_r$, substrate height h, strip width w of the microstrip line and pulse width $\tau$ of signal pulse. The simulation results show that small relative permittivity and small rationale of w/h are advantageous for the dispersion of the pulse signals, and that pulse signals with small bandwidth cause smaller dispersion. The results of this paper are compatible to the trade-off determination of relative permittivity, substrate height, strip width and pulse width of signal pulse when a design of MIC and MMIC is necessary.

  • PDF

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.

Prospects about Nuclear Electro Magnetic Pulse developed by North Korea (북한의 핵전자기파(NEMP)탄 개발에 대한 전망)

  • Lee, Dae Sung
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • The international community recognizes North Korea's nuclear and missile provocation as a real threat. This is due to the analysis and evaluation that has developed nuclear electro magnetic pulse of domestic and overseas North Korea experts, intelligence agencies related to electro magnetic pulse. Electro magnetic pulse experts are concerned about North Korea's nuclear electro magnetic pulse in the following aspects. First, industrial, military, medical, and living facilities in modern society are constructed with electrical and electronic systems. So, All electrical and electronic appliances will become neutralization if North Korea's nuclear electro magnetic pulse was set off over the world(i.e. Korean Peninsula, United States etc). Second, North Korea will judge that possibility of criticism by the international community is low from the point of view of an attacker. Because nuclear electro magnetic pulse aim to destroy only the electronic equipment of the opposite nation and cause damage rather than taking life. Finally, nuclear electro magnetic pulse is more threatening than weapons like mass destruction because it does not need to hit targets accurately and can strike a wide area with nuclear weapon of the low technology levels. In this respect, we will analyze and evaluate nuclear and missile development and make a prospects about nuclear electro magnetic pulse developed by North Korea.

A Study on High-Repetition Rate Optical-Pulse for Loop-Mirror (루프 미러를 이용한 고 반복률 펄스 발생에 관한 연구)

  • Jeoung Chan-gwoun;Kim Sun-youb;Kang Young-jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1117-1122
    • /
    • 2005
  • This paper is studied the high-repetition rate optical-pulse stream generation using optical loop mirror coupler. With the recent development of the ultrahigh-speed optical time division multiplexed system, hish-repetition rate optical-pulse stream generation is necessary. This is different from conventional approaches, which use fiber or integrated waveguide delay line circuits. The high-repetition-rate optical-pulse multiplication phenomenon occurs when the optical pulse's spectral width is greater than the transfer bandwidth of the coupler used. From the analysis, the output repetition rate can be controlled by using fiber couplers with different equivalent transfer bandwidths. The pulse separation spacing is controlled by number of cascaded coupler in optical loop mirror coupler scheme.