• Title/Summary/Keyword: pulse I-V

Search Result 161, Processing Time 0.021 seconds

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.285-285
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

Analysis of a modulated pulse plasma system by a triple probe and ICCD-OES (삼중 프로브와 ICCD-OES를 이용한 modulated pulse plasma의 분석)

  • Choe, Ji-Seong;Yang, Won-Gyun;Ju, Jeong-Hun;Jang, Dong-Su;Lee, Jeong-Jung
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.192-193
    • /
    • 2012
  • 2차 플라즈마를 사용하지 않고도 스퍼터링된 입자의 높은 이온화율을 얻을 수 있는 고전력 마그네트론 스퍼터링 기술은 최대 $MW/cm^2$의 높은 투입 전력을 이용하지만 타겟 재료의 높은 열전도 요구때문에 실제로 사용할 수 있는 재료가 Cu를 비롯한 몇가지 금속에 제한된다. 수 백 $kW/cm^2$의 중간 전력 밀도를 가질 수 있도록 펄스를 다중 부분 세트로 제어하는 modulated pulse plasma 시스템을 구축하고 전자 온도, 밀도를 고속으로 계측할 수 있는 삼중 프로브와 고증폭 CCD를 이용하여 공정 진단을 한 결과 전자 온도는 최고 15.9 eV, 전자 밀도는 $4.25{\times}10^{12}{\sharp}/cm^3$였으며 weak ionization 조건과 strong ionization 조건에서 Ar I (811.5 nm)의 방출광 세기가 6배 증가하는 것으로 분석되었다.

  • PDF

CMOS-IC Implementation of a Pulse-type Hardware Neuron Model with Bipolar Transistors

  • Torita, Kiyoko;Matsuoka, Jun;Sekine, Yoshifumi
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.615-618
    • /
    • 2000
  • A number of studies have recently been made on hardware for a biological neuron f3r application with information processing functions of neural networks. We have been trying to produce hardware from the viewpoint that development of a new hardware neuron model is one of the important problems in the study of neural networks. In this paper, we first discuss the circuit structure of a pulse-type hardware neuron model with the enhancement-mode MOSFETs (E-MOSFETs). And we construct a pulse-type hardware neuron model using I-MOSFETs. As a result, it is shown that our proposed new model can exhibit firing phenomena even if the power supply voltage becomes less than 1.5[V]. So it is verified that our model is profitable for IC.

  • PDF

The Kinetics of Hyperpolarization Activated Current$(i_f)$ in Sinoatrial Node of the Rabbit (토끼 동방결결에서 Pacemaker전류(과분극에 의해 활성화되는 내향전류, $i_f$)의 동력학적 특성에 관한 연구)

  • Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 1983
  • 1) The two microelectrode method was used to voltage clamp small preparations of rabbit sinoatrial node. The kinetics of hyperpolarization activated inward current, $i_f$ were analysed. 2) The hrperpolarization pulses activated $i_f$ current in the presence of $10^{-7}g/ml$ TTX and 2 mM $Mn^{2+}$. The activation range was in between -45 mV to -75 mV. The current magnitude was increased and time course was faster by strong hyperpolarization pulses. 3) Standard envelope tests indicated that this current is exponentially controlled by single gate. 4) Semilogarithmic plot of $i_f$ activation versus time was found to be linear in the activation range. The decrease in current magnitude and the shifts in activation curve and rate constants curve to the hyperpolarizing direction were obtained with $Ba^{2+}$, indicating that $Ba^{2+}$ shifts the voltage dependence of the gating kinetics, were partially reversed by 24 mM $K^+$.

  • PDF

Prediction of Venturi Effect on Pressure Drop in Pulse Air Jet Bag Filter (충격기류식 여과집진장치에서 벤츄리가 압력손실에 미치는 영향)

  • Moon-Sub Jung;Jung-Kwon Kim;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.9
    • /
    • pp.659-669
    • /
    • 2023
  • The purpose of this study is to predict the pressure drop due to the installation of venturi under diverse operating conditions such as dust concentration, pulse interval and pressure, and filtration velocity using algebraic-linear regression model and use it as an economic data and efficient operating condition for a pulse air jet bag filter. A pilot scale bag filter with a filter a filter size(Ø140 × 850ℓ, 12) was used, and the filters used in the experiment were the polyester filters most commonly used in real industrial sites. The SAS 9.4 program (SAS Institute, USA) was used to predict and to determine the effects of inlet concentration (Ci), pulse interval (Pi) and pressure (Pp), filtration velocity (Vf), presence or absence of venturi, etc. The results are shown below. The variation in pressure drop with or without venturi installation was 38.8 mmAq when venturi is installed and 47.6 mmAq when venturi is not installed, indicating a difference in pressure drop of 8.8 mmAq depending on venturi installation. It is estimated that the efficiency can be improved by about 18.5% if the venturi is installed.

Observations of Pulsed Bi-polar Discharges in Saline Solutions with Pin to Plate Electrodes

  • Shin, Bhum Jae;Seo, Jeong-Hyun;Collins, George J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2011-2016
    • /
    • 2018
  • In this study, we have been investigated pin to plate pulsed bi-polar discharges in saline solutions, where bubble generation occurs. We integrate basic I-V-t electrical characteristics with the ICCD shadowgraph images, and finally instant and time averaged I-V waveforms. We observed that the bubble formation phase dynamics is quite different corresponding to the polarity applied to the pin electrode. When the pin electrode is a cathode, the bubble tends to be periodically detached from the pin electrode and the numerous tiny voltage spikes occur related to the electron emission from a pin cathode casing via, we judge from, direct dissociation of water molecules by energetic electrons. On the contrary, the bubble tends to stick to the pin electrode, when the pin electrode is anode; the bubble grows in size throughout the pulse duration. The dynamic electrical characteristics relative to the applied polarity of a pin electrode are presented and discussed by analysis of time averaged I-V waveforms.

Inactivation of Listeria monocytogenes in Brine and Saline by Alternating High-Voltage Pulsed Current

  • Lee, Mi-Hee;Han, Dong-Wook;Woo, Yeon-I.;Uzawa, Masakazu;Park, Jong-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.7
    • /
    • pp.1274-1277
    • /
    • 2008
  • The inactivating efficiency of alternating high-voltage pulsed (AHVP) current was investigated in brine (20 w/v% NaCl) and saline (0.9 w/v% NaCl) inoculated with $1\times10^7$ cells/ml of Listeria monocytogenes. AHVP current at 12 V with 1 pulse completely inactivated L. monocytogenes in brine within 3 ms, while the bacteria in saline were fully inactivated by 10-pulsed electric treatment at 12 V within the same time. Electron microscopic observation demonstrated substantial structural damage of electrically treated L. monocytogenes in brine. These results suggest that AHVP treatment would be effective for the rapid and complete inactivation of L. monocytogenes in brine or saline solution.

I-V Characteristics of Negatively DC Pulsed Target in ECR Plasma for Landmine Detection (지뢰탐지를 위한 ECR 플라즈마에서 타깃에 고전압 DC 펄스 인가시 전압-전류 특성 분석)

  • Kim, Seong Bong;Lee, Hui Jea;Park, Seungil;Yoo, Suk Jae;Cho, Moohyun;Han, Seung-Hoon;Lim, Byeongok
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.1
    • /
    • pp.53-56
    • /
    • 2014
  • I-V characteristics of a cylindrical target in an ECR plasma were studied for sheath spatial evolutions when the target was pulsed biased to a high negative potential. The magnetic field effects on sheath thickness and sheath boundary speed were investigated by comparison between the experimental results and the theoretical results using the Child-Langmuir sheath model. The results showed that the magnetic field suppressed electron motion away from the target so that sheath thickness and sheath boundary speed decreased.

Development of the TVC Battery for High Voltage Loads in KSLV-I Upper Stage (KSLV-I 상단부 고전압 부하용 TVC 배터리 개발)

  • Kim, Myung-Hwan;Ma, Keun-Sum;Lim, You-Chol;Lee, Jae-Deuk
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.110-116
    • /
    • 2008
  • This paper gives a brief summary of the TVC battery design description, specifications and test results. The TVC battery for KSLV-I upper stage contains 168 Sony l8650VT high power lithium-ion cells. It configured as 2 strings in parallel, with each string containing 84 series connected cells. This allows to meet nominal 270V voltage and capacity requirements specified for the mission of the Thrust Vector Control(TVC) system. The loads profile of the TVC system has short duration, high current pulse. To power such a system with minimal mass, the battery employed l8650VT Cells. This cell is specifically designed for high rate applications and is capable of a 10C continuous discharge.

  • PDF