• Title/Summary/Keyword: pre-exposure

Search Result 362, Processing Time 0.027 seconds

Patterns of Spontaneous Adverse Events Reporting on Human Papillomavirus Vaccines according to the Applicability of Brighton Collaboration Criteria in Korea from 2008 to 2017 (국내 사람유두종바이러스백신 접종 후 자발적 이상반응 보고사례의 Brighton Collaboration 기준 활용 가능성 연구)

  • Kim, Myo-Song;You, Seung-Hun;Park, Hye Min;Lee, Min-Taek;Kang, Ye-Jin;Koo, Hyunji;Jung, Sun-Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.30 no.1
    • /
    • pp.19-30
    • /
    • 2020
  • Objective: To describe patterns of spontaneous reporting on adverse events following immunization (AEFIs) using the human papilloma virus (HPV) vaccine according to the Brighton Collaboration (BC) criteria. Methods: We used the Korea Adverse Event Reporting System (KAERS) database including vaccinations between 2008 and 2017. To apply BC criteria, we classified 58 BC AEFIs into World Health Organization Adverse Reaction Terminology (WHO-ART) codes. We applied MedDRA standard medical queries that were pre-defined as five BC AEFIs. Terminology mapping between MedDRA and WHO-ART terms was performed by three researchers. Descriptive statistics of individual case safety reports were analyzed according to BC applicability. Disproportionality analyses were performed on each BC AEFI and each preferred AEFI term according to the case-noncase approach; reporting odds ratio (ROR) and 95% confidence intervals (CI) were calculated. Results: Among the 30,266 reports of vaccinations between 2008 and 2017, 2,845 reports included the HPV vaccine. Of these reports, 1,511 (53.1%) included at least one BC AEFI. Reports from physicians or manufacturers included more BC AEFIs than from other reporters. Injection site reactions and fever were frequently reported in BC AEFIs; spontaneous abortion and ectopic pregnancy (ROR, 14.29 [95% CI, 4.30-47.49]) and vasculitic peripheral neuropathy (ROR, 8.57 [95% CI, 2.61-28.10]) showed the highest ROR. Among non-BC AEFIs, dizziness or myalgia were frequently reported; exposure during pregnancy (ROR, 23.95 [95% CI, 16.27-35.25]) and inappropriate schedule of administration (ROR, 22.89 [95% CI, 16.74-31.31]) showed the highest ROR. Conclusion: BC criteria would be applicable for labeled AEFIs, whereas analyzing non-BC AEFIs would be useful for detecting unlabeled AEFIs.

Survey Study on Radioactivity of Domestic Fishery Product (국내 시중 유통 수산물에 대한 방사능 농도 조사)

  • Kim, Chang-Jong;Lim, Chung-seop;Lee, Wanno;Jang, Mee;Ji, Young-Yong;Chung, Kun-Ho;Kang, and Mun-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.789-792
    • /
    • 2015
  • Samples of fishery products were tested for radioactivity by using the intake frequency data from Korea Health Statistics. The radioactivity of $^{40}K$, $^{137}Cs$, $^{134}Cs$, and $^{131}I$ was analyzed using gamma spectrometry with a simplified sample pre-treatment procedure. The radioactivity range for $^{40}K$ was 21.9-3050 Bq/kg, whereas the radioactivities of $^{137}Cs$, $^{134}Cs$, and $^{131}I$ were under minimum detectable activity which were in the range of 0.140-1.97, 0.0900-1.89 and 0.124-1.94 Bq/kg, respectively, for the three species. The results suggest that the Fukushima accident did not have a significant impact on domestic fishery products, which were analyzed during the period from 2013 to 2015. Additionally, there seemed to be no significant impact of additional exposure dose by the analyzed radionuclides.

Design of Real-Time PreProcessor for Image Enhancement of CMOS Image Sensor (CMOS 이미지 센서의 영상 개선을 위한 실시간 전처리 프로세서의 설계)

  • Jung, Yun-Ho;Lee, Joon-Hwan;Kim, Jae-Seok;Lim, Won-Bae;Hur, Bong-Soo;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.62-71
    • /
    • 2001
  • This paper presents a design of the real-time digital image enhancement preprocessor for CMOS image sensor. CMOS image sensor offers various advantages while it provides lower-quality images than CCD does. In order to compensate for the physical limitation of CMOS sensor, the spatially adaptive contrast enhancement algorithm was incorporated into the preprocessor with color interpolation, gamma correction, and automatic exposure control. The efficient hardware architecture for the preprocessor is proposed and was simulated in VHDL. It is composed of about 19K logic gates, which is suitable for low-cost one-chip PC camera. The test system was implemented on Altera Flex EPF10KGC503-3 FPGA chip in real-time mode, and performed successfully.

  • PDF

Sodium Salicylate Activates p38MAPK Though a Specific-Sensing Mechanism, Distinct from Pathways Used by Oxidative Stress, Heat Shock, and Hyperosmotic Stress

  • Kim, Jung-Mo;Oh, Su-Young;Kim, Min-Young;Seo, Myoung-Suk;Kang, Chi-Duk;Park, Hye-Gyeong;Kang, Ho-Sung
    • Biomedical Science Letters
    • /
    • v.9 no.4
    • /
    • pp.241-248
    • /
    • 2003
  • Sodium salicylate, a plant stress hormone that plays an important role(s) in defenses against pathogenic microbial and herbivore attack, has been shown to induce a variety of cell responses such as anti-inflammation, cell cycle arrest and apoptosis in animal cells. p38MAPK plays a critical role(s) in the cell regulation by sodium salicylate. However, the signal pathway for sodium salicylate-induced p38MAPK activation is yet unclear. In this study, we show that although sodium salicylate enhances reactive oxygen species (ROS) production, N-acetyl-L-cysteine, a general ROS scavenger, did not prevent sodium salicylate-induced p38MAPK, indicating ROS-independent activation of p38MAPK by sodium salicylate. Sodium salicylate-activated p38MAPK appeared to be very rapidly down-regulated 2 min after removal of sodium salicylate. Interestingly, sodium salicylate-pretreated cells remained fully responsive to re-induction of p38MAPK activity by a second sodium salicylate stimulation or by other stresses, $H_2O$$_2$ and methyl jasmonate (MeJA), thereby indicating that sodium salicylate does not exhibit both homologous and heterologous desensitization. In contrast, pre-exposure to MeJA, $H_2O$$_2$, heat shock, or hyperosmotic stress reduced the responsiveness to subsequent homologous stimulation. Sodium salicylate was able to activate p38MAPK in cells desensitized by other heterologous p38MAPK activators. These results indicate that there is a sensing mechanism highly specific to sodium salicylate for activation of p38MAPK, distinct trom pathways used by other stressors such as MeJA, $H_2O$$_2$ heat shock, and hyperosmotic stress.

  • PDF

Reliability and Accuracy of the Deployable Particulate Impact Sampler for Application to Spatial PM2.5 Sampling in Seoul, Korea (서울시 PM2.5 공간 샘플링을 위한 Deployable Particulate Impact Sampler의 성능 검증 연구)

  • Oh, Gyu-Lim;Heo, Jong-Bae;Yi, Seung-Muk;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.277-288
    • /
    • 2017
  • Previous studies of health effects of $PM_{2.5}$ performed spatial monitoring campaigns to assess spatial variability of $PM_{2.5}$ across people's residences. Highly reliable portable and cost-effective samplers will be useful for such campaigns. This study aimed to investigate applicability of the Deployable Particulate Impact Sampler(DPIS), one of the compact impact samplers, to spatial monitoring campaigns of $PM_{2.5}$ in Seoul, Korea. The investigation focused on the consistency of $PM_{2.5}$ concentrations measured by DPISs compared to those by the Low-volume Cyclone sampler (LCS). LCS has operated at a fixed site in the Seoul National University Yeongeon campus, Seoul, Korea since 2003 and provided qualified $PM_{2.5}$ data. $PM_{2.5}$ sampling of DPISs was carried out at the same site from November 17, 2015 through February 3, 2016. $PM_{2.5}$ concentrations were quantified by the gravimetric method. Using a duplicated DPIS, we confirmed the reliability of DPIS by computing relative precision and mean square error-based R squared value ($R^2$). Relative precision was one minus the difference of measurements between two samplers relative to the sum. For accuracy, we compared $PM_{2.5}$ concentrations from four DPISs (DPIS_Tg, DPIS_To, DPIS_Qg, and DPIS_Qo) to those of LCS. Four samplers included two types of collection filters(Teflon, T; quartz, Q) and impaction discs(glass fiber filter, g; pre-oiled porous plastic disc, o). We assessed accuracy using accuracy value which is one minus the difference between DPIS and LCS $PM_{2.5}$ relative to LCS $PM_{2.5}$ in addition to $R^2$. DPIS showed high reliability (average precision=97.28%, $R^2=0.98$). Accuracy was generally high for all DPISs (average accuracy=83.78~88.88%, $R^2=0.89{\sim}0.93$) except for DPIS_Qg (77.35~78.35%, 0.82~0.84). Our results of high accuracy of DPIS compared to LCS suggested that DPIS will help the assessment of people's individual exposure to $PM_{2.5}$ in extensive spatial monitoring campaigns.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

Effects of Exposure Period on the Developmental Toxicity of 2-Bromopropane in Sprague-Dawley Rats

  • Shin, In-Sik;Lee, Jong-Chan;Kim, Kang-Hyeon;Ahn, Tai-Hwan;Bae, Chun-Sik;Moon, Chang-Jong;Kim, Sung-Ho;Shin, Dong-Ho;Kim, Jong-Choon
    • Toxicological Research
    • /
    • v.24 no.4
    • /
    • pp.263-271
    • /
    • 2008
  • Recently we reported that 2-bromopropane (2-BP) has maternal toxicity, embryotoxicity, and teratogenicity in Sprague-Dawley rats. The aims of this study are to examine the potential effects of 2-BP administration on pregnant dams and embryo-fetal development, and to investigate the effects of metabolic activation induced by phenobarbital (PB) on developmental toxicities of 2-BP. Pregnant rats received 1000 mg/kg/day subcutaneous 2-BP injections on gestational days (GD) 6 through 10 (Group II and Group IIII) or 11 through 15 (Group IV). Pregnant rats in Group III received an intraperitoneal PB injection once daily at 80 mg/kg/day on GD 3 through 5 for induction of the liver metabolic enzyme system. Control rats received vehicle injections only on GD 6 through 15. All dams underwent caesarean sections on GD 20 and their fetuses were examined for external, visceral, and skeletal abnormalities. Significant adverse effects on pregnant dams and embryo-fetal development were observed in all the treatment groups, and the maternal and embryo-fetal effects of 2-BP observed in Group II were higher than those seen in Group IV. Conversely, maternal and embryo-fetal developmental toxicities observed in Group III were comparable to those seen in Group II. These results suggest that the potential effects of 2-BP on pregnant dams and embryo-fetal development are more likely in the first half of organogenesis (days $6{\sim}10$ of pregnancy) than in the second half and that the metabolic activation induced by PB pre-treatment did not modify the developmental toxic effects of 2-BP in rats.

HYDROLYTIC DEGRADATION OF DENIAL COMPOSITE RESINS (수종 치과용 복합레진의 가수분해)

  • Yang, Kyu-Ho;Kim, Jung-Ran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.370-378
    • /
    • 2000
  • The composite restorative resins have their insufficient resistance to wear. The subsurface degradation within the restoration is considered to be associated with wear. The aim of this study was to evaluate the resistance to degradation of six commercial composite resins in an alkaline solution. The brands studied were Clearfil APX(Kuraray), Heliomolar(Vivadent), Surefil(Dentsply), TPH(Dentsply), Tetric Ceram(Vivadent), and Z100(3M). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCL, washed with water and dried to constant mass at $60^{\circ}C$. Resistance to degradation was evaluated on the basis of the following parameters: (a) mass loss(%) - determined from pre-and post-exposure specimen weights; (b) Si loss (ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were as follows: 1. The mass loss was in descending order by Z100, TC H, S, CL, TPH and in the range of $0.45\sim3.64%$ 2. The degradation layer depth was in descending order by H, Z100, S, TC, TPH, CL and in the range of $10.85\sim73.38{\mu}m$ 3. For the Si concentration, Z100 was the highest of all 4. The highly significant correlation(r=0.81, p<0.05) was observed between mass loss and degradation depth. 5. Under scanning electronmicroscopy, the degradation of connection between resin matrix and fillers was observed 2 weeks after soaking in NaOH solution.

  • PDF

Study on the Development of Modularized Instruction and the Effect of Its Application - Focused on the Asepsis and Elimination Practice - (기본 간호학 실습교육에서 모듈 학습자료 개발과 그 효과 연구 - 감염과 배설에 관한 실습 교육을 중심으로)

  • Jeong, Hyeon-Suk
    • The Korean Nurse
    • /
    • v.33 no.3
    • /
    • pp.56-69
    • /
    • 1994
  • This study was done to develop self - directed learning modules related to asepsis and elimination including urine and stool for Fundamentals in Nursing practice education contents and to measure the effectiveness of those modules. The subjects of this study were 96 sophomore students in the nursing college. Self-directed learning modules were developed by the researcher on the basis of the Lippincott Learning System of Kruger (1986) and Modules for Basic Nursing Care of Ellis (1992). Videotape was editted by using videotape made by the Lippincott Company and Film strip made by the Trainex Company with Korean dubbing. Self-directed learning was done for one week with the asepsis module and two weeks with the elimination modules after confirming the requiered level of knowledge acquisition through pre-test. For measuring proficiency in self-directed learning, a written test for cognitive domain, a sufficiency test for psychomotor domain, and a confidnece examination for affective domain were given. The data were analyzed using descritive statistics, and Pearson correlation coefficient using a SPSS-PC program. The results are summarized as follows: 1. Sufficiency test and confidence examination grades showed high levels in both asepsis and elimination. 2. Written test grades showed a high level in asepsis and elimination of urine but showed a medium level in eliminationin of stool. 3. Grades of sufficiency and confidence in asepsis and elimination practice were statistically significant with a moderate positive correlation (r=0.4- 0.5, p<0.001). 4. Grades of sufficiency and written tests in asepsis and elimination practice also were statistically significant with a moderate positive correlation (r=0.5-0.7, p<0.001). 5. Students showed relatively high contentment with the self-directed learning modules themselves but revealed relatively low contentment with video program and the self-directed learning process. In conclusion, this study disclosed that proficiency levels in cognitive, affective, and psychomotor domains were high when asepsis and elimination modules were applied. Also students showed high satisfaction with the modules themselves, but didn't show high contentment with the video programs. In considering low contentment with the self-directed learning process, it is estimated the students had experienced some difficulties about using self-directed learning modules because this was their first exposure to the self-directed learning module and they were already accustomed to the demonstration-practice method.

  • PDF

Analysis of Air Discharge and Disused Air Filters in Radioisotope Production Facility

  • Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • When air discharged from a radioisotope production facility is contaminated with radiation, the public may be exposed to radiation. The objective of this study is to manage such radiation exposure. We measured the airborne radioactivity concentration at a 30 MeV cyclotron radioisotope production facility to assess whether the exhaust gas was contaminated. Additionally, we investigted the radioactive contamination of the air filter for efficient air purification and radiation safety control. To measure the airborne radiation concentration, specimens were collected weekly for 4 h after the beginning of the radioisotope production. Regarding the air purifier, five specimens were collected at different positions of each filter-pre-filter, high-efficiency particulate air filter, and charcoal filter-installed in the cyclotron production room. The concentrations of F-18, I-123, I-131, and Tl-201 generated in the radioiodine production room were $13.5Bq/m^3$, $27.0Bq/m^3$, $0.10Bq/m^3$, and $11.5Bq/m^3$, respectively; the concentrations of F-18, I-123, and I-131 produced in the radioisotope production room were $0.05Bq/m^3$, $16.1Bq/m^3$, and $0.45Bq/m^3$, correspondingly; and those of F-18, I-123, I-131, and Tl-201 generated in the accelerator room were $2.07Bq/m^3$, $53.0Bq/m^3$, $0.37Bq/m^3$, and $0.15Bq/m^3$, respectively. The maximum radiation concentration of I-123 generated in the radioiodine production room was 1,820 Bq/g, which can be disposed after 2 days. The maximum radiation concentration of Tl-202 generated in the radioisotope production room was 205 Bq/g, and this isotope must be stored for 53 days. The I-123 generated in the radioiodine production room had a maximum concentration of 1,530 Bq/g and must be stored for 2 days. The maximum radiation concentration of Na-22 generated in the radioisotope production room was 0.18 Bq/g and this isotope must be disposed after 827 days. To manage the exhaust, the efficiency of air purification must be enhanced by selecting an air purifier with a long life and determining the appropriate replacement time by examining the differential pressure through systematic measurements of the airborne radiation contamination level.