• Title/Summary/Keyword: potential and current noise

Search Result 87, Processing Time 0.02 seconds

A Study on the Generation of the Earth Potential and Communication Line Noise. (대지전위와 통신회선 잡음 발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF

INTERPRETATION OF ELECTROCHEMICAL NOISE PARAMETERS AS INDICATORS OF INITIATION AND PROPAGATION OF SCC OF AN ALLOY 600 SG TUBE AT HIGH TEMPERATURES

  • Kim, Sung-Woo;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1315-1322
    • /
    • 2009
  • The present article is concerned with the application of an electrochemical noise (EN) monitoring technique to analyze the initiation and propagation of Pb-assisted stress corrosion cracking (SCC) of an Alloy 600 material in a simulated environment of a steam generator (SG) sludge pile at high temperatures. A typical increase of electrochemical current noise (ECN) and electrochemical potential noise (EPN) was frequently recorded from the EN measurement in a caustic solution with such impurities as PbO and CuO, indicating that there are localized corrosion events occurring. With the aid of microscopic and spectral analyses, the EN data involving information on such stochastic processes as uniform corrosion and the initiation and propagation of SCC, were analyzed based on a stochastic theory.

Electrochemical Random Signal Analysis during Localized Corrosion of Anodized 1100 Aluminum Alloy in Chloride Environments

  • Sakairi, M.;Shimoyama, Y.;Nagasawa, D.
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.168-172
    • /
    • 2008
  • A new type of electrochemical random signal (electrochemical noise) analysis technique was applied to localized corrosion of anodic oxide film formed 1100 aluminum alloy in $0.5kmol/m^3$ $H_3BO_4/0.05kmol/m^3$ $Na_2B_4O_7$ with $0.01kmol/m^3$ NaCl. The effect of anodic oxide film structure, barrier type, porous type, and composite type on galvanic corrosion resistance was also examined. Before localized corrosion started, incubation period for pitting corrosion, both current and potential slightly change as initial value with time. The incubation period of porous type anodic oxide specimens are longer than that of barrier type anodic oxide specimens. While pitting corrosion, the current and potential were changed with fluctuations and the potential and the current fluctuations show a good correlation. The records of the current and potential were processed by calculating the power spectrum density (PSD) by the Fast Fourier Transform (FFT) method. The potential and current PSD decrease with increasing frequency, and the slopes are steeper than or equal to minus one (-1). This technique allows observation of electrochemical impedance changes during localized corrosion.

A Study on the Generation of the Earth Potential and Communication Line Noise (대지전위와 통신회선 잡음.발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.181-189
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

Study on Localized Corrosion Cracking of Alloy 600 using EN-DCPD Technique (EN-DCPD 방법을 이용한 Alloy 600 재료의 국부부식균열 연구)

  • Lee, Yeon-Ju;Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.93-101
    • /
    • 2013
  • The object of this work is to establish an electrochemical noise(EN) measurement technique combined with a direct current potential drop(DCPD) method for monitoring of localized corrosion cracking of nickel-based alloy, and to analyze its mechanism. The electrochemical current and potential noises were measured under various conditions of applied stress to a compact tension specimen in a simulated primary water chemistry of a pressurized water reactor. The amplitude and frequency of the EN signals were evaluated in both time and frequency domains based on a shot noise theory, and then quantitatively analyzed using statistical Weibull distribution function. From the spectral analysis, the effect of the current application in DCPD was found to be effectively excluded from the EN signals generated from the localized corrosion cracking. With the aid of a microstructural analysis, the relationship between EN signals and the localized corrosion cracking mechanism was investigated by comparing the shape parameter of Weibull distribution of a mean time-to-failure.

Elucidation of the Noise in Corrosion of Aluminum Foil

  • Chiba, Atsushi;Hattori, Atsushi;Wu, Weng-Chang
    • Corrosion Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.102-106
    • /
    • 2004
  • Al foil used was 99.9 and 99.99 %. Test solution used was NaCl solution. The noise was determined using controlled potential electrolysis at -200 and -700 mV vs. NHE. The current fluctuation was caused by breakdown and repaired process of aluminum oxide film. The current fluctuation value of noise was proportion to degree of growth. The number of noise was proportion to the number of pit. The examining of current flutulation value and number of noise could be evaluated corrosion. A 99.99 % Al foil was the mostly crystal of {100} plane, and showed three-dimensional, as azimuth pit with along the direction of this place piled up. A 99.9 % Al foil was polycrystal, and in order of (311) >(222) >(200) >(111) plane. The azimuth pit did not occurred as the dissolution was occurred from each plane.

Evaluation of High Order Statistical Parameter for Electrochemical Noise Analysis

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.296-299
    • /
    • 2008
  • High order statistical parameters were evaluated using the electrochemical noise data collected during corrosion of type 430 stainless steel coupled to a inert, platinum electrode in 3.5% NaCl solution. High order statistical parameters are shown to predict uniform corrosion properly. However, Localization index, skewness of current, kurtosis and skewness of potential are capable of predicting pitting corrosion only when the transients are large with long life time. Of the high order statistical parameters evaluated, kurtosis of current is found to be the most sensitive parameter for detecting uniform and pitting corrosion.

Evaluation of BSR Noise Properties of Instrument Panel in a Vehicle (자동차 계기판 BSR 소음특성 평가)

  • Shin, Su-Hyun;Cheong, Cheol-Ung;Kim, Duck-Whan;Jung, Sung-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.644-650
    • /
    • 2010
  • Among various elements to affect customer's evaluation of vehicle quality, BSR(Buzz, Squeak, Rattle) are considered to be a mostly contributing factor. In this paper, we provide the test method which can be used to reduce the BSR noise of instrument panel in a vehicle. First, potential source regions of the instrument panel for BSR are localized by using the vibration-excitor and near-acoustic field visualization system. Then, subjective evaluation of BSR noise from the detected potential noise source regions is made with the Zwicker's loudness and time-varying loudness methods. This illustrative analysis reveals that current experimental methods can be used as a test procedure to systematically tackle BSR issues in early stage of the vehicle development cycle, which can result in the reduction of the production cost.

Electromyo-potential Response to Electric Stimulus Excitation at a Human Antebrachial Joint (인체 주관절에서 전기자극 가진에 의한 근전위 응답)

  • Hong, Jong Han;Kim, Jin Oh;Lee, Dong Chan;Park, Kwang Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2013
  • This paper experimentally deals with the excitation by functional electrical stimulus(FES) and the response of electromyo-potential at the muscles of antebrachial joint in a human body. The excitation of FES, which results in the contraction of the muscles and thus the flection of the joint, shows that the flection angle of the joint is proportional to the magnitude of the stimulus current. The response of electromyo-potential measured according to the FES shows the linearly-proportional relation between the joint torque and the electromyo-potential. The results can be used for active motion of joint rehabilitation.

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.