• 제목/요약/키워드: polishing methods

검색결과 199건 처리시간 0.019초

원통내면의 자기연마에 관한 연구 (A Study on Internal Surface Finishing of Tube Using Magnetic Assisted Polishing)

  • 이용철;박상길;송치성;이종렬;이득우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.792-795
    • /
    • 2000
  • The magnetic assisted finishing thought to be one of the potential methods for the automatic polishing process. In this study, magnetic assisted finishing process was experimentally attempted to polish the intrnal surface of the cylindrical tube. The newly developed magnetic tool was used, and its polishing performance exmined. From the experimental results, it is found that i ) the newly developed tool is suitable for intrnal surface finishing of the tube. ii ) the surface roughness of 0.9~1${\mu}{\textrm}{m}$Rmax before polishing is improved to the value of 0.2 ${\mu}{\textrm}{m}$Rmax in the finishing experiment of stainless steel STS3602L tube in 6 minutes finishing time.

  • PDF

연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화 (Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods)

  • 오주원;서재민;안승근;박주미;강철균;송광엽
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.106-111
    • /
    • 2012
  • 연구 목적: 본 연구는 탄성의치 제작 시 주로 사용되는 polyamide를 수종의 연마방법을 사용하여 처리 후 $Candida$ $albicans$의 부착정도와 표면거칠기를 비교하고자 하였다. 연구 재료 및 방법: $25{\times}15{\times}2mm$ 크기의 polyamide 시편을 4군으로 나누어 연마재를 사용하여 기공용 lathe 연마하는 방법(기공실내 연마방법)과 각기 다른 2종의 실리콘 포인트로 진료실내 연마하는 방법, 그리고 실리콘포인트 연마 후 pumice로 연마하는 방법으로 처리하였다. $C.$ $albicans$의 부착성을 평가하기 위해 $5{\times}10^6CFU/ml$$C.$ $albicans$ 현탁액에 시편을 2시간 동안 침적하였고 5회 수세처리 후 한천배지에서 배양하였다. 그리고 주사전자 현미경(JSM-5900, JEOL LTd., Tokyo, Japan) 촬영을 시행하였다. Profilometer (Surf-pak; Kawasaki, Japan)를 이용하여 표면거칠기를 측정하였고 통계처리를 위하여 SPSS 18.0 프로그램을 사용하였다. 일원변량분석으로 비교 분석하였고 사후 검증은 $C.$ $albicans$의 부착성 검증을 위해 Scheffe test를 시행하였으며 표면조도검증을 위해 Tamhane's T2 test를 시행하였다(${\alpha}$=.01). 결과: 최대 거칠기 값을 보인 군은 2단계의 연마용 버를 사용한 것으로 $0.32{\mu}m{\pm}0.10$ 값을 나타냈으며, 가장 낮은 거칠기 값을 보인 것은 tungsten carbide를 사용하지 않고 기공용 lathe로만 연마를 한 군으로 $0.02{\mu}m{\pm}0.00$의 거칠기 값을 나타냈다. $C.$ $albicans$ 부착 실험에서는 기공용 lathe만을 이용한 연마방법이 가장 적은 부착수를 보였으며 다른 세 군과 유의한 차이가 발견되었다($P$<.01). 결론: 표면거칠기 및 미생물 부착능 실험 결과 기공실 연마만을 시행한 경우 유의하게 낮은 거칠기 값과 부착율을 보였다. Pumice로 추가 연마한 군은 진료실연마를 시행한 군에 비해 낮은 거칠기 값을 보였으나 $C.$ $albicans$ 부착에 있어서는 유의한 차이를 보이지 않았다($P$>.01).

클로르헥시딘을 이용한 치과기공용 연마기 캔디다균의 감염방지 (Prevention of Candida albicans infection in dental polishing lathe by chlorhexidine)

  • 송영균
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.274-279
    • /
    • 2016
  • 목적: 치과 기공용 연마기 휠을 소독하기 위한 클로르헥시딘의 농도에 따른 캔디다균의 감염방지효과에 대해 알아보고자 하였다. 연구 재료 및 방법: 동일한 모형에서 제작된 상악 총의치를 캔디다균에 감염시키고, 서로 다른 농도의 클로르헥시딘 용액에 1시간 보관한 연마 휠과 멸균된 퍼미스와 증류수를 이용하여, 치과기공용 연마기로 연마하였다. 이후 멸균된 상악 총의치를 연이어 연마한 뒤 연마한 부위를 면봉으로 채취하여, 재배양후 칸디다균의 여부를 확인하였다. 결과: 클로르 헥시딘을 적용한 연마휠은 농도에 관계 없이 감염의 전파가 일어나지 않았으나, 증류수만을 사용한 연마휠에서는 감염의 전파가 나타났다. 결론: 의치 연마기 휠의 감염방지를 위해 클로르헥시딘 용액은 효과적이다.

Effects of different finishing/polishing protocols and systems for monolithic zirconia on surface topography, phase transformation, and biofilm formation

  • Mai, Hang-Nga;Hong, Su-Hyung;Kim, Sung-Hun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.81-87
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the effects of various protocols and systems for finishing and polishing monolithic zirconia on surface topography, phase transformation, and bacterial adhesion. MATERIALS AND METHODS. Three hundred monolithic zirconia specimens were fabricated and then treated with three finishing and polishing systems (Jota [JO], Meisinger [ME], and Edenta [ED]) using four surface treatment protocols: coarse finishing alone (C); coarse finishing and medium polishing (CM); coarse finishing and fine polishing (CF); and coarse finishing, medium polishing, and fine polishing (CMF). Surface roughness, crystal phase transformation, and bacterial adhesion were evaluated using atomic force microscopy, X-ray diffraction, and streptococcal biofilm formation assay, respectively. One-way and two-way analysis of variance with Tukey post hoc tests were used to analyze the results (${\alpha}=.05$). RESULTS. In this study, the surface treatment protocols and systems had significant effects on the resulting roughness. The CMF protocol produced the lowest roughness values, followed by CM and CF. Use of the JO system produced the lowest roughness values and the smallest biofilm mass, while the ME system produced the smallest partial transformation ratio. The ED group exhibited the highest roughness values, biofilm mass, and partial transformation ratio. CONCLUSION. Stepwise surface treatment of monolithic zirconia, combined with careful polishing system selection, is essential to obtaining optimal microstructural and biological surface results.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.

Technical Overview on the Electron Backscattered Diffraction Sample Preparation

  • Kim, Dong-Ik;Kim, Byung-Kyu;Kim, Ju-Heon
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.218-224
    • /
    • 2015
  • A technical overview on the various sample preparation methods for electron backscattered diffraction (EBSD) analysis is carried out. The mechanical polishing with colloidal silica finish, electro-chemical polishing, dual layer coating and ion beam milling are introduced for the common sample preparation methods for EBSD observation and some issues that are frequently neglected by the common EBSD users but should be considered to get a reliable EBSD data are discussed. This overview would be especially helpful to the people who know what EBSD technique is but do not get a reliable EBSD data because of difficulties in sample preparation.

연마방법에 따른 복합레진의 표면특성 평가 (Effects of Polishing Methods on the Surface Characteristics of Composite Resins)

  • 백민경;김종철;장기택
    • 대한소아치과학회지
    • /
    • 제43권3호
    • /
    • pp.275-283
    • /
    • 2016
  • 본 연구는 복합레진의 연마방법에 따른 표면특성을 평가하기 위해, microhybrid 레진(Filtek$^{TM}$ Z250)과 nanofill 레진(Filtek$^{TM}$ Z350)을 연마 전, abrasive disk(Sof-lex) 연마 후, polishing brush(Occlubrush) 연마 후로 나누어 분석하였다. 그 결과 레진 표면조도는 연마 후 증가하였는데, 미세조도는 연마방법에 따른 차이가 없었으나 거시조도는 Occlubrush를 이용한 경우 현저하게 커졌다(p < 0.05). Sof-lex 연마의 경우 레진의 filler까지 연마되어 표면이 보다 균일한 형상을 보였으나 Occlubrush 연마시편은 기질층이 뜯겨져 나간 불균일한 형상을 보였다. 두 연마방법 간의 미세경도 유의차는 없었으며(p > 0.05), 연마 후 경도 값이 약 25% 상승하였다. 결론적으로, 복합레진의 표면경도 향상을 위하여 적합한 연마가 필요하며, Sof-lex를 이용한 연마가 더 우수한 것으로 사료된다.

표면연마와 제작방법에 따른 임시 수복용 레진의 굽힘강도에 관한 비교 연구 (Comparative study of flexural strength of temporary restorative resin according to surface polishing and fabrication methods)

  • 임재훈;이재인
    • 구강회복응용과학지
    • /
    • 제37권1호
    • /
    • pp.16-22
    • /
    • 2021
  • 목적: 표면연마와 제작방법이 임시 수복용 레진의 굽힘강도에 미치는 영향을 분석하고자 한다. 연구 재료 및 방법: 4가지 제작방법을 이용하여 각각 30개의 임시 수복용 레진 시편을 제작하였고, 기계적 연마로 표면연마를 시행한 그룹과 연마를 시행하지 않은 2개의 그룹으로 나누었다. 시편은 37℃ 항온기에 24시간 보관 후 만능시험기(Universal testing machine)을 이용하여 3점 굽힘강도를 측정하였다. 통계분석은 Two-way ANOVA와 Tukey's HSD test, Paired t-test를 이용하여 분석하였다. 결과: 표면연마 여부와 관계없이 CAD/CAM milling으로 제작한 시편이 가장 높은 굽힘강도를 나타냈고, SLA 3D printing, DLP 3D printing, Conventional method 순으로 높은 굽힘강도를 나타냈다. 결론: 표면연마는 임시 수복용 레진의 굽힘강도에 유의한 영향을 끼치지 못했지만(P > 0.05), 제작방법에 의해서는 굽힘강도의 유의한 차이가 나타났다(P < 0.05).

자외선 광을 활용하는 화학기계적 연마에 관한 연구 동향 (Research Trends on Chemical Mechanical Polishing Using Ultraviolet Light)

  • 이현섭
    • Tribology and Lubricants
    • /
    • 제38권6호
    • /
    • pp.247-254
    • /
    • 2022
  • Chemical mechanical polishing (CMP) is a hybrid surface-polishing process that utilizes both mechanical and chemical energy. However, the recently emerging semiconductor substrate and thin film materials are challenging to process using the existing CMP. Therefore, previous researchers have conducted studies to increase the material removal rate (MRR) of CMP. Most materials studied to improve MRR have high hardness and chemical stability. Methods for enhancing the material removal efficiency of CMP include additional provision of electric, thermal, light, mechanical, and chemical energies. This study aims to introduce research trends on CMP using ultraviolet (UV) light to these methods to improve the material removal efficiency of CMP. This method, photocatalysis-assisted chemical mechanical polishing (PCMP), utilizes photocatalytic oxidation using UV light. In this study, the target materials of the PCMP application include SiC, GaN, GaAs, and Ru. This study explains the photocatalytic reaction, which is the basic principle of PCMP, and reviews studies on PCMP according to materials. Additionally, the researchers classified the PCMP system used in existing studies and presented the course for further investigation of PCMP. This study aims to aid in understanding PCMP and set the direction of future research. Lastly, since there have not been many studies on the tribology characteristics in PCMP, research on this is expected to be required.

Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing

  • Yoon, Hyung-In;Noh, Hyo-Mi;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.188-194
    • /
    • 2017
  • PURPOSE. This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were $3.02{\pm}0.34{\mu}m$, $2.44{\pm}0.72{\mu}m$, and $3.49{\pm}0.72{\mu}m$, respectively. Surface roughness of lithium disilicate increased from $2.35{\pm}1.05{\mu}m$ (pristine) to $28.54{\pm}9.64{\mu}m$ (scaling), and further increased after polishing ($56.66{\pm}9.12{\mu}m$, P<.05). The zirconia showed the most increase in roughness after scaling (from $1.65{\pm}0.42{\mu}m$ to $101.37{\pm}18.75{\mu}m$), while its surface roughness decreased after polishing ($29.57{\pm}18.86{\mu}m$, P<.05). CONCLUSION. Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.