• 제목/요약/키워드: performance test

검색결과 21,718건 처리시간 0.04초

FRP복합체로 보강된 실물모형 RC보의 보강재 강성에 따른 휨 보강성능 (Flexural Performance of Full-scale RC Beams Strengthened with Different Amount of FRP Composite)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.125-128
    • /
    • 2006
  • Many research have been carried out concerned with the flexural performance of FRP composite in a various ways. Most of them, however, have used a small-scale specimen, so haven't been fully verified by full-scale model test. In this study, a full-scale RC beam model test for flexural strengthening with CFRP composites has been performed in order to verify test results obtained through a series of small-scale model test with respect to FRP stiffness affecting strengthening performance in the previous studies. A total of 4 specimens have been manufactured including control beam. The specimens strengthened with CFRP composites consist of 3 different CFRP stiffness with 2 types of CFRP composite. Consequently, the purpose of this study is to estimate influence of the size effect of specimens and FRP stiffness on the flexural performance. As a result, the effective strain of FRP composite is inversely proportional to FRP stiffness and ensures the same performance with small-scale model test.

  • PDF

극초음속 충격파 풍동 설계/구축 및 성능시험 Part II : 극초음속 충격파 풍동 구축 및 성능 시험 (Design/Construction and Performance Test of Hypersonic Shock Tunnel Part ii : Construction and Performance Test of Hypersonic Shock Tunnel)

  • 이형진;이복직;김세환;정인석
    • 한국항공우주학회지
    • /
    • 제36권4호
    • /
    • pp.328-336
    • /
    • 2008
  • 극초음속으로 비행하는 추진기관이 직면하는 고속 유동 등 제반 현상을 모사하기 위한 지상시험 설비로 충격파 풍동을 설계, 구축한 후 성능 시험을 수행하였다. 개발된 준 일차원 작동 해석을 이용하여 설계점을 파악한 후, 가압식 극고속 시험 구축을 위한 개념 설계를 완료하였다. 이어 단위 해석 코드를 이용하여 구체적인 성능 설계 및 각 구성품에 대한 설계를 완료, 구축한 후, 다양한 운용조건에서 성능시험을 수행하였다. 본 논문에서는 각 구성품 설계 및 구축방법, 구축 후 수행된 다양한 성능 시험 결과를 자세히 제시하였다.

무시멘트 첨가제를 활용한 상온 재활용 아스팔트 혼합물의 성능 분석 (Performance Evaluation of Cold Recycled Asphalt Mixtures with Asphalt Emulsion and Inorganic Additives)

  • 박창규;김경수;김원재;이현종
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.137-142
    • /
    • 2017
  • PURPOSES :The objective of this study is to evaluate the performance of asphalt mixtures containing inorganic additive and a high content of reclaimed asphalt pavement (RAP). METHODS : The laboratory tests verified the superior laboratory performance of inorganic additive compared to cement, in cold recycled asphalt mixtures. To investigate the moisture susceptibility of the specimens, tensile strength ratio (TSR) tests were performed. In addition, dynamic modulus test was conducted to evaluate the performance of cold recycled asphalt mixture. RESULTS :It was determined that NaOH solution mixed with $Na_2SiO_3$ in the ratio 75:10 provides optimum performance. Compared to Type B and C counterparts, Type A mixtures consisting of an inorganic additive performed better in the Indirect tensile strength test, tensile strength ratio test, and dynamic modulus test. CONCLUSIONS : The use of inorganic additive enhances the indirect strength and dynamic modulus performance of the asphalt mixture. However, additional experiments are to be conducted to improve the reliability of the result with respect to the effect of inorganic additive.

방염도료의 방염성능 및 발연특성에 관한 연구 (A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint)

  • 김황진;이성은;오규형
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.78-83
    • /
    • 2009
  • 방염도료의 주성분 및 특성에 따른 방염성능과 발연특성에 대하여 알아보기 위하여 국내에 유통되어지는 17종의 방염도료를 MDF에 방염처리하여 45도 연소실험과 연기밀도실험을 실시하였다. 45도 연소실험 결과 주성분별로는 아크릴 수지를 주성분으로 한 방염도료의 방염성능이 가장 우수한 것으로 평가되어지며 유성방염도료 보다는 수성방염도료의 방염성능이 우수한 것으로 나타났고 또한 무광방염도료보다 유광방염도료의 방염성능이 더 우수한 것으로 평가되었다. 연기밀도실험을 통한 발연특성은 아크릴 수지를 주성분으로 한 시료에서 연기밀도가 상대적으로 낮게 측정되었으며 특성별로는 수성방염도료를 처리한 시료들에서 유성방염도료를 칠한 시료보다 연기밀도가 낮게 측정되었다.

건물내장재(석고보드, 합판)의 화재성능평가 (The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood))

  • 김충환;김종훈;김운형;하동명;이수경
    • 한국화재소방학회논문지
    • /
    • 제15권3호
    • /
    • pp.55-62
    • /
    • 2001
  • 본 연구는 국내와 외국의 건물 내장재 화재성능평가방법을 고찰하고 국내에는 도입되지 않은 실대 화재실험인 Room Corner Test를 국내 내장재중 석고보드와 합판을 대상으로 그 적용성을 위한 실험을 진행하였다. 현재 국내 내장재의 평가규정은 Bench-Scale Test에 의존하고 있으나, 미국, 일본 유럽등에서는 Room Corner Test를 적용한 실질적인 재료의 화재성능평가를 시행하고 있다. 실험 결과, NFPA 265에 의한 석고보드 및 ISO 9705에 의한 합판의 성능은 양호한 것으로 판단되었다. 현재 국내 내장재에 적용되는 등급분류의 평가방법은 재료의 실제 화재성능 평가에 한계가 있으므로 향후 Room Corner Test의 적용과 더불어 Bench-Scale Test 결과를 토대로 화재성능을 예측하는 화재모델을 이용하는 평가 방법의 도입이 필요하다.

  • PDF

Relationship Between Strength of Hip Muscles and Performance of Close Kinetic Chain Dynamic Lower Extremity Stability Test

  • Lee, Hyeon-ju;Hwang, Ui-jae;Jung, Sung-hoon;Ahn, Sun-hee;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제27권4호
    • /
    • pp.257-263
    • /
    • 2020
  • Background: The hip muscle plays various roles. Several types of functional performance tests are used for the assessment of patients with various lower extremity injuries. Hip muscle functions are important to test the performance of maintaining the spine, pelvic, and leg during bridging exercise. We designed a novel functional performance test tool, which we named close kinetic chain dynamic lower extremity stability (CKCLE) test to assess hip muscle functions. Objects: The purpose of this study was to determine the relationship between CKCLE test and hip extensor, external rotator, and abductor strengths. Methods: Twenty-two subjects were recruited in the present study (13 males and 9 females). The hip extensor, external rotator, and abductor muscle strengths were measured using a Smart KEMA strength sensor. When the examiner said "Go", the subject performed the CKCLE test by moving one leg from the floor and touching the opposite knee and then return to the floor while maintaining the bridging position. The subjects attempted as many "touches" as possible in the allotted time (20 seconds) during the maximal tests. The correlation between the hip muscle (extensor, external rotator, and abductor) strength of the supporting leg and the number of CKCLE tests performed in 20 seconds was determined using the Pearson correlation. Results: Hip extensor (r = 0.626, p < 0.05), hip external rotator (r = 0.616, p < 0.05), and hip abductor muscle strengths (r = 0.475, p < 0.05) positively correlated with the number of CKCLE tests performed. Conclusion: We designed a CKCLE test and found that performance in the test correlated with hip extensor, external rotator, and abductor muscle strengths. The result suggests that the CKCLE test can be applied as a performance test to assess the functions of the hip extensor, external rotator, and hip abductor muscles.

터보펌프 조립체의 수력 성능 시험 (Hydrodynamic Performance Test of a Turbopump Assembly)

  • 홍순삼;김대진;김진선;김진한
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.249-254
    • /
    • 2008
  • Hydrodynamic performance test of a turbopump for a liquid rocket engine is carried out. The turbopump is composed of an oxidizer pump, a fuel pump and a turbine, and the two pumps are driven by the turbine. In the test, water is used for the pumps as working media and air is used for the turbine. Performance parameters of pumps and a turbine are drawn, and a power balance between the pumps and the turbine are calculated. The calculation shows a good power balance, which implies that the pump component tests, the turbine component test and the assembly test are reliably performed. At the starting period of the test, pressure rise-flow rate curve of a pump gradually approaches the ideal curve which could be obtained by very slow starting.

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

알루미늄 합금 피스톤과 스틸 단조 피스톤의 내구성능에 관한 실험적 연구 (An Experimental Study on Durability Performance of Aluminum Alloy Piston and Steel Forging Piston)

  • 김현철;이종인;박종호
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.54-59
    • /
    • 2004
  • The goal of this research is to confirm reliable durability and evaluate the engine performance of the current aluminum alloy piston and the newly developed steel forging piston. For such purpose, the test environment was built with 2.91 target engine mounted on the engine dynamometer and additional exhaust gas analysis system. Using the test environment, engine performance test was conducted, and durability test was also conducted using a dedicated piston durability test equipment for 400,000 km. As a result of the experiment, similar durability was appeared for both aluminum piston and steel piston, and the engine output power and torque are slightly reduced because of $158\%$ heavier weight of the steel piston compare to the aluminum alloy piston.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.