Browse > Article

Insulation Performance Estimation of Main Relays by Partial Discharges  

Kil, Gyung-Suk (한국해양대학교 전기전자공학부)
Kim, Il-Kwon (한국해양대학교 대학원)
Park, Dae-Won (한국해양대학교 대학원)
Song, Jae-Yong (국립과학수사연구소)
Lee, Gang-Won (한국철도기술연구원 바이모달수송시스템연구단)
Cho, Eun-Je (부산교통공사 호포차량사업소 검사2담당)
Publication Information
Journal of the Korean Society for Railway / v.10, no.4, 2007 , pp. 388-392 More about this Journal
Abstract
A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.
Keywords
Dielectric Test; Partial Discharge; Insulation Performance; Discharge Inception Voltage; Discharge Extinction Voltage;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A. Lapp and H. G. Kranz. (2000). 'The use of CIGRE data form at for PD diagnosis application', IEEE Trans. on DEI, Vol. 7, No. 1, pp.102   DOI   ScienceOn
2 IEC 60-1, 1995, Medical electrical equipment-Part 1: General requirements for safety, International Electrotechnical Commission
3 KS R 9197, 1996, 철도차량의 절연저항 및 내전압 시험방법, Korean Standards Association
4 A. Kelen and M. G. Danikas. (1994). 'Evidence and presumption in PD diagnostics', IEEE Trans. on DEI, Vol. 2, No. 5, pp.780
5 건설교통부 고시, 2000, 도시철도차량의 성능시험에 관한 기준, 건설교통부
6 A. Mbaye, F. Grigorescu, T. Lebey, and Bui Ai. (1996). 'Existence of partial discharges in low-voltage induction machines supplied by PWM drives', IEEE Trans. on DEI, Vol. 3, No. 4, pp.554   DOI   ScienceOn
7 W. Pfeiffer. (1991). 'Partial-discharge testing of components for low-voltage equipment', IEEE Trans. on DI, Vol. 31, No. 4, pp.247
8 IEC 60664-1, 2002, Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests, International Electrotechnical Commission
9 KS C 2127, 1996, 절연 재료의 내전압 시험 방법, Korean Standards Association
10 IEC 60270, 2001, High-voltage test techniques - Partial discharge measurement, International Electrotechnical Commission
11 IEC 61558-1, 2005, Safety of power transformers, power supplies, reactors, and similar products, International Electro-technical Commission