Insulation Performance Estimation of Main Relays by Partial Discharges

부분방전에 의한 주계전기의 절연성능 평가

  • 길경석 (한국해양대학교 전기전자공학부) ;
  • 김일권 (한국해양대학교 대학원) ;
  • 박대원 (한국해양대학교 대학원) ;
  • 송재용 (국립과학수사연구소) ;
  • 이강원 (한국철도기술연구원 바이모달수송시스템연구단) ;
  • 조은제 (부산교통공사 호포차량사업소 검사2담당)
  • Published : 2007.08.31

Abstract

A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

Keywords

References

  1. KS C 2127, 1996, 절연 재료의 내전압 시험 방법, Korean Standards Association
  2. A. Kelen and M. G. Danikas. (1994). 'Evidence and presumption in PD diagnostics', IEEE Trans. on DEI, Vol. 2, No. 5, pp.780
  3. A. Lapp and H. G. Kranz. (2000). 'The use of CIGRE data form at for PD diagnosis application', IEEE Trans. on DEI, Vol. 7, No. 1, pp.102 https://doi.org/10.1109/94.839347
  4. W. Pfeiffer. (1991). 'Partial-discharge testing of components for low-voltage equipment', IEEE Trans. on DI, Vol. 31, No. 4, pp.247
  5. A. Mbaye, F. Grigorescu, T. Lebey, and Bui Ai. (1996). 'Existence of partial discharges in low-voltage induction machines supplied by PWM drives', IEEE Trans. on DEI, Vol. 3, No. 4, pp.554 https://doi.org/10.1109/94.536735
  6. IEC 60-1, 1995, Medical electrical equipment-Part 1: General requirements for safety, International Electrotechnical Commission
  7. IEC 60664-1, 2002, Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests, International Electrotechnical Commission
  8. IEC 61558-1, 2005, Safety of power transformers, power supplies, reactors, and similar products, International Electro-technical Commission
  9. KS R 9197, 1996, 철도차량의 절연저항 및 내전압 시험방법, Korean Standards Association
  10. 건설교통부 고시, 2000, 도시철도차량의 성능시험에 관한 기준, 건설교통부
  11. IEC 60270, 2001, High-voltage test techniques - Partial discharge measurement, International Electrotechnical Commission