• 제목/요약/키워드: pH detection

검색결과 1,098건 처리시간 0.033초

STEREO VISION-BASED FORWARD OBSTACLE DETECTION

  • Jung, H.G.;Lee, Y.H.;Kim, B.J.;Yoon, P.J.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • 제8권4호
    • /
    • pp.493-504
    • /
    • 2007
  • This paper proposes a stereo vision-based forward obstacle detection and distance measurement method. In general, stereo vision-based obstacle detection methods in automotive applications can be classified into two categories: IPM (Inverse Perspective Mapping)-based and disparity histogram-based. The existing disparity histogram-based method was developed for stop-and-go applications. The proposed method extends the scope of the disparity histogram-based method to highway applications by 1) replacing the fixed rectangular ROI (Region Of Interest) with the traveling lane-based ROI, and 2) replacing the peak detection with a constant threshold with peak detection using the threshold-line and peakness evaluation. In order to increase the true positive rate while decreasing the false positive rate, multiple candidate peaks were generated and then verified by the edge feature correlation method. By testing the proposed method with images captured on the highway, it was shown that the proposed method was able to overcome problems in previous implementations while being applied successfully to highway collision warning/avoidance conditions, In addition, comparisons with laser radar showed that vision sensors with a wider FOV (Field Of View) provided faster responses to cutting-in vehicles. Finally, we integrated the proposed method into a longitudinal collision avoidance system. Experimental results showed that activated braking by risk assessment using the state of the ego-vehicle and measuring the distance to upcoming obstacles could successfully prevent collisions.

Amperometric Detection of Hydroquinone and Homogentisic Acid with Laccase Immobilized Platinum Electrode

  • Quan, De;Shin, Woon-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.833-837
    • /
    • 2004
  • DeniLite$^{TM}$ laccase immobilized platinum electrode was used for amperometric detection of hydroquinone (HQ) and homogentisic acid (HGA) by means of substrate recycling. In case of HQ, the obtained sensitivity is 280 nA/ ${\mu}$M with linear range of 0.2-35 ${\mu}$M ($r^2$ = 0.998) and detection limit (S/N = 3) of 50 nM. This high sensitivity can be attributed to chemical amplification due to the cycling of the substrate caused by enzymatic oxidation and following electrochemical regeneration. In case of HGA, the obtained sensitivity is 53 nA/ ${\mu}$M with linear range of 1-50 $[\mu}M\;(r^2$ = 0.999) and detection limit of 0.3 ${\mu}$M. The response times ($t_{90%}$) are about 2 seconds for the two substrates and the long-term stability is 60 days for HQ and around 40-50 days for HGA with retaining 80% of initial activities. The very fast response and the durable long-term stability are the principal advantages of this sensor. pH studies show that optimal pH of the sensor for HQ is 6.0 and that for HGA is 4.5-5.0. This shift of optimal pH towards acidic range for HGA can be attributed to the balance between enzyme activity and accessibility of the substrate to the active site of the enzyme.

Reduced Graphene Oxide Field Effect Transistor for Detection of H+ Ions and Their Bio-sensing Application

  • Sohn, Il-Yung;Kim, Duck-Jin;Yoon, Ok-Ja;Tien, N.T.;Trung, T.Q.;Lee, N.E.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.195-195
    • /
    • 2012
  • Recently, graphene based solution-gated field-effect transistors (SGFETs) have been received a great attention in biochemical sensing applications. Graphene and reduced graphene oxide (RGO) possess various advantages such as high sensitivity, low detection limit, label-free electrical detection, and ease of fabrication due to their 2D nature and large sensing area compared to 1D nanomaterials- based nanobiosensors. Therefore, graphene or RGO -based SGFET is a good potential candidate for sensitive detection of protons (H+ ions) which can be applied as the transducer in various enzymatic or cell-based biosensing applications. However, reports on detection of H+ ions using graphene or RGO based SGFETs have been still limited. According to recent reports, clean graphene grown by CVD or exfoliation is electrochemically insensitive to changes of H+ concentration in solution because its surface does not have terminal functional groups that can sense the chemical potential change induced by varying surface charges of H+ on CVD graphene surface. In this work, we used RGO -SGFETs having oxygen-containing functional groups such as hydroxyl (OH) groups that effectively interact with H+ ions for expectation of increasing pH sensitivity. Additionally, we also investigate RGO based SGFETs for bio-sensing applications. Hydroloytic enzymes were introduced for sensing of biomolecular interaction on the surface of RGO -SGFET in which enzyme and substrate are acetylcholinesterase (AchE) and acetylcholine (Ach), respectively. The increase in H+ generated through enzymatic reaction of hydrolysis of Ach by AchE immobilized on RGO channel in SGFET could be monitored by the change in the drain-source current (Ids).

  • PDF

The Chemical Kinetics for the Reaction of O(³P) with Ethylene

  • 임종태;조경용;최창열;박호림;최중길;Simon H. Bauer
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권7호
    • /
    • pp.595-600
    • /
    • 1995
  • The kinetics of the reaction between O(3P) and C2H4 was investigated by measuring time-dependent concentrations of OH resulting from the reaction by using the LIF detection. Oxygen atoms were generated by titrating microwave discharged N2/He with NO to the chemiluminescent end point. The operating pressures in the flow reactor ranged from 5 to 15 torr and the mixtures consisted of He/O(3/P)/C2H4 in the approximate ratios from 100/1/0.1 to 100/1/1. The controlled residence time prior to the detection were estimated to be 0.8-17 ms at the reactor pressure of 7 torr. Experimentally determined profiles both in shape and magnitude were compared with the computed OH density for a specified set of experimental parameters, allowing us to arrive at a complete mechanism for the reaction of O(3P) with ethylene.

심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기 (An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity)

  • 권혁제;이정환;윤지영;최성균;이준영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF

용존산소와 pH의 동시 검출용 광학 센서 막을 이용한 미생물 발효공정의 온라인 모니터링 (On-line monitoring of microorganism cultivation processes using optical sensing membranes for simultaneous detection of dissolved oxygen and pH)

  • 김춘광;이종일
    • KSBB Journal
    • /
    • 제24권1호
    • /
    • pp.106-112
    • /
    • 2009
  • An optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen(DO) and pH value simultaneously. It has employed HPTS as a pH sensitive dye and a ruthenium(II) complex as a DO sensitive dye. The sensing membrane has been applied to wells in a 24-well microtiter plate. Using the 24-well microtiter plate the concentrations of dissolved oxygen and pH values have been on-line monitored during the cultivations of E.coli DH5${\alpha}$, B.cereus 318 and P.pastoris X-33. On-line monitoring of DO and pH in microorganism cultivation processes showed good performance of the sensing membrane containing 5 mM HPTS and 2 or 5 mg/mL Rudpp.

황산화미생물을 이용한 새로운 수(水)중 생태독성탐지 방법 (A New Methodology of Measuring Water Toxicity using Sulfur Oxidizing Bacteria)

  • 오상은
    • 대한환경공학회지
    • /
    • 제32권6호
    • /
    • pp.555-562
    • /
    • 2010
  • 수중의 독성을 탐지하기 위하여 황산화미생물을 이용한 새로운 형태의 생태독성탐지 방법이 연구되었다. 황산화미생물이 산소 존재 하에서 황입자를 산화하여 황산을 만들게 되고 이는 EC의 증가 및 pH의 감소를 가져온다. 독성물질이 들어오면 미생물의 저해로 황산을 적게 만들게 되므로 EC의 증가 정도가 감소하게 된다. 인공하천수(EC= 0.12 mS/cm and pH=7.2)를 이용하여 황산화미생물을 배양하고 반응조를 HRT 30분으로 연속 운전한 결과 유출 인공하천수의 EC=0.5~1.2 mS/cm, pH= ~2.5이었으며 7일 동안 일정하게 유지되었다. 이러한 유입수와 유출수의 EC의 차이는 인공하천수가 독성이 없는 조건에서 일정 속도로 황산을 만들었기 때문이다. 아질산성질소 2 mg/L를 함유한 인공하천수를 넣은 결과 인공하천수 주입 후 1.5시간 경과 후 EC 값이 급격하게 감소하고 pH 값은 상승하여 독성을 쉽게 탐지 가능하였다. 최적의 체류시간은 30분이었으며 이는 황입자의 크기를 줄임으로써 더 짧은 체류시간에서 운전이 가능할 것으로 판단된다.

세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석 (Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions)

  • 장지운;황인숙;이종목;이선민;강소라;김영미;김나영
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Rapid Detection of SdhBP225F and SdhBH272R Mutations in Boscalid Resistant Botrytis cinerea Strains by ARMS-PCR

  • Liu, Xin;Zeng, Rong;Gao, Shigang;Xu, Lihui;Dai, Fuming
    • The Plant Pathology Journal
    • /
    • 제35권1호
    • /
    • pp.71-76
    • /
    • 2019
  • $SdhB^{P225F}$ and $SdhB^{H272R}$ mutations have been found associated with boscalid resistance in Botrytis cinerea from strawberry in Shanghai, China. For rapid detection of two mutations, tetra-primers were designed and optimized to gain the relatively high accuracy and specificity based on the ARMS-PCR technique, by which resistance can be identified with different lengths of products on agarose gels. The tetra-primer ARMS-PCR systems for $SdhB^{P225F}$ and $SdhB^{H272R}$ were validated by 9 SdhB-squenced strains repeatedly. Then, sensitivity of 30 more strains were also tested by the methods, which were accordant with genotypes by sequencing and the sensitivity of conidial germination to boscalid by 100%. Thus, the methods developed in this study are proved to be rapid, inexpensive, accurate and practical for resistance detection of Botrytis cinerea caused by $SdhB^{P225F}$ and $SdhB^{H272R}$ mutations.

Elution Buffers for Human Enteric Viruses in Vegetables with Applications to Norovirus Detection

  • Moon, Aerie;Ahn, Jaehyun;Choi, Weon Sang
    • 한국식품위생안전성학회지
    • /
    • 제28권4호
    • /
    • pp.287-292
    • /
    • 2013
  • 오염된 식품으로부터 바이러스를 효과적으로 검출하기 위해서는 식품에 부착된 바이러스를 효과적으로 elute시키는 것이 결정적으로 중요하다. 본 연구에서는 채소류에 공통적으로 적용할 수 있는 elution용액을 찾기 위해 폴리오 바이러스를 인위적으로 오염시킨 1가지 엽채류 (깻잎) 와 3가지 근채류 (당근, 양파, 무) 로부터 바이러스 회수율을 조사한 후, 최적의 바이러스 회수조건을 찾기 위해 기보고된 상추와 양배추의 회수율을 함께 분석하였다. 바이러스의 회수율은 식품의 matrix와 사용된 elution용액의 종류에 따라 차이가 컸으나 0.25M threonine / 0.3M NaCl (pH 9.5) 또는 0.25M glycine / 0.14M NaCl (pH 9.5)을 사용하였을 때 6가지 채소 중 5가지로부터 폴리오바이러스를 효과적으로 elute 할 수 있었다. 0.25M threonine / 0.3M NaCl(pH 9.5)를 노로바이러스 검출에 적용해 본 결과 근채류인 당근보다 엽채류인 깻잎으로부터 노로바이러스 GII를 더 잘 검출할 수 있었다. 이 같은 공통 elution용액을 사용할 경우 다양한 종류의 채소류에 오염된 노로바이러스를 포함한 소화기바이러스의 검출을 용이하게 해 줄 것이다.