• 제목/요약/키워드: optical transmission system

검색결과 626건 처리시간 0.037초

Design and Implementation of Open-Loop Clock Recovery Circuit for 39.8 Gb/s and 42.8 Gb/s Dual-Mode Operation

  • Lim, Sang-Kyu;Cho, Hyun-Woo;Shin, Jong-Yoon;Ko, Je-Soo
    • ETRI Journal
    • /
    • 제30권2호
    • /
    • pp.268-274
    • /
    • 2008
  • This paper proposes an open-loop clock recovery circuit (CRC) using two high-Q dielectric resonator (DR) filters for 39.8 Gb/s and 42.8 Gb/s dual-mode operation. The DR filters are fabricated to obtain high Q-values of approximately 950 at the 40 GHz band and to suppress spurious resonant modes up to 45 GHz. The CRC is implemented in a compact module by integrating the DR filters with other circuits in the CRC. The peak-to-peak and RMS jitter values of the clock signals recovered from 39.8 Gb/s and 42.8 Gb/s pseudo-random binary sequence (PRBS) data with a word length of $2^{31}-1$ are less than 2.0 ps and 0.3 ps, respectively. The peak-to-peak amplitudes of the recovered clocks are quite stable and within the range of 2.5 V to 2.7 V, even when the input data signals vary from 150 mV to 500 mV. Error-free operation of the 40 Gb/s-class optical receiver with the dual-mode CRC is confirmed at both 39.8 Gb/s and 42.8 Gb/s data rates.

  • PDF

WDM 광전송시스템의 감시제어 기능실현을 위한 경보신호 적용에 관한 연구 (A Study on the Application of Alarm Signals for the Realization of OAM Function in the WDM Optical Transmission System)

  • 이창기;차영욱
    • 한국정보처리학회논문지
    • /
    • 제7권9호
    • /
    • pp.2958-2968
    • /
    • 2000
  • WDM 시스템에서 효과적으로 감시제어 기능을 수행하기 위해서는 경보신호의 적용이 요구된다. 그러나 광전달망의 각 계층별 적용되어야 할 경보신호에 대한 연구는 현재까지 아직 기초적인 상태에 머물러 있고, 그리고 감시채널의 구조와 구성에 대해서 제안된 연구결과가 없다. 따라서 본 논문은 ITU-T 광전달망의 요구사항을 기초로 하고, 자국과 대구 및 텐덤 구간의 신호 감시기법을 적용하여 단국형과 ADM형 WDM 시스템 모두에 적용할 수 있는 각 계층별 경보신호와 이의 전파 체계를 제시하였고, 감시채널의 구성 및 오버헤드 구조를 보였다. 또한 단국형과 ADM 형의 WDM 시스템에서 다양하게 발생할 수 있는 장애상태에서도 감시제어 기능을 효과적으로 수행할 수 있음을 보였다.

  • PDF

다파장 OCDMA 네트웍에서의 새로운 2차원 코드의 설계 (Design of a new family of multi wavelength two-dimensional codes for optical code division multiple access networks)

  • 유경식;박남규
    • 한국통신학회논문지
    • /
    • 제25권1B호
    • /
    • pp.31-41
    • /
    • 2000
  • 본 논문에서는 광 코드 분할 다중화방식 (OCDMA)에서 사용할 수 있는 ‘파장’과 ‘시간’영역에서는 준 직교 성질을 가지는 다파장 2 차원 코드의 구성 방법을 새로이 제안하였다. ‘파장’과‘시간’영역에서 직교 특성을 가지는 다파장 OCDMA 방삭은 동시 사용자의 수나 오류 확률 등의 여러 측면에서 기존이 다중 사용자 접속 방식에 비해 우수한 성능을 보인다. 특히, 새로 제안된 코드는 브래그 격자를 이용한 광학적 신호 처리 기법으로 생성, 해독 될 수 있어 전기적 신호 처리로 인한 병목 현상을 줄일 수 있는 장점을 가지고 있다.

  • PDF

The Development of Double Clad Fiber and Double Clad Fiber Coupler for Fiber Based Biomedical Imaging Systems

  • Ryu, Seon-Young;Choi, Hae-Young;Ju, Myeong-Jin;Na, Ji-Hoon;Choi, Woo-June;Lee, Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.310-315
    • /
    • 2009
  • We report the fabrication of double clad fiber (DCF) and DCF coupler, suitable for fiber based imaging systems requiring the dual-channel transmission. Unlike the conventional DCF which uses silica for both cladding layers, the proposed DCF uses a low-index polymer for its outer-cladding layer coated over the conventional silica inner-cladding layer. The DCF is drawn with a conventional SMF preform but a low-index polymer coating is used for both jacket and outercladding of the fiber. To achieve the cladding mode coupling, a DCF coupler is fabricated by simply twisting two pieces of the proposed DCF after removing the polymer-coating at contacting regions. A cladding mode coupling ratio of 30% was achieved with a contact length of 16 cm. The proposed DCF and DCF coupler were employed in a composite optical coherence tomography (OCT) and fluorescence spectroscopy (FS) system, and both OCT images and FS signal from a plant tissue are measured simultaneously.

파장분할 다중화 수동광 네트워크에서 적용된 반사형 반도체 증폭기 기반의 광역선폭 광원의 광필터 특성 의존성 (The Optical Filtering Effect of a RSOA-based Broadband Light Source in a Bidirectional WDM-PON System)

  • 최보훈
    • 한국광학회지
    • /
    • 제22권3호
    • /
    • pp.122-128
    • /
    • 2011
  • 하향신호를 위해서는 반사형 반도체 증폭기를 기반으로 한 광역선폭 광원 기술이 사용되었고 상향신호를 위해서는 파장 재사용 기술이 사용된 양방향 파장분할 다중화 수동 광네트워크 (WDM-PON)가 컴퓨터 시뮬레이션을 통해 구현되었다. 이 시스템에서 세가지 다른 종류의 광필터들이 비교되어 필터링의 영향이 분석되었고, 광 스펙트럼과 아이 다이어그램 (eye diagram)의 분석을 통해 파장 재변조 기술을 최적화 하였다. 최적화된 시스템 조건을 이용하여 양방향 신호의 전송 성능 곡선을 구하였고 이 시스템에서 반사에 의한 신호 왜곡의 영향을 분석하였다.

WDM 슬러티드 링 네트워크의 MAC 프로토콜 성능분석 (Performance analysis of a MAC protocol on WDM slotted ring networks)

  • 박강수;정수환;김종훈;신종덕
    • 한국통신학회논문지
    • /
    • 제25권6A호
    • /
    • pp.893-899
    • /
    • 2000
  • 광섬유의 대역폭을 보다 효율적으로 활용하기 위한 방안으로 각각의 채널에 서로 다른 파장을 사용하여 하나의 광섬유에 동시에 전송하는 파장분할 다중화 방식(WDM, Wavelength Division Multiplexing)이 최근 주목받고 있다. WDM 전송 시스템은 광 송수신기의 비용이 고가이므로 경제적인 구축을 위해서는 최소한의 광 송수신기를 사용하여야 하고 성능 파라미터인 전송률(throghput)과 시간 지연의 분석이 중요한 의미를 갖는다. 본 논문에서는 각 노드에 단일 큐 버퍼와 각각 1개씩의 파장가변송신기(TTX), 파장가변수신기(TRX), 파장고정수신기(FRX)가 장착된 슬러티드 링 MAC 프로토콜을 통계적 접근 방법으로 분석하였으며 컴퓨터 실험을 통하여 분석의 타당성을 검증하였다.

  • PDF

Simulative Investigation of Spectral Amplitude Coding Based OCDMA System Using Quantum Logic Gate Code with NAND and Direct Detection Techniques

  • Sharma, Teena;Maddila, Ravi Kumar;Aljunid, Syed Alwee
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.531-540
    • /
    • 2019
  • Spectral Amplitude Coding Optical Code Division Multiple Access (SAC OCDMA) is an advanced technique in asynchronous environments. This paper proposes design and implementation of a novel quantum logic gate (QLG) code, with code construction algorithm generated without following any code mapping procedures for SAC system. The proposed code has a unitary matrices property with maximum overlap of one chip for various clients and no overlaps in spectra for the rest of the subscribers. Results indicate that a single algorithm produces the same length increment for codes with weight greater than two and follows the same signal to noise ratio (SNR) and bit error rate (BER) calculations for a higher number of users. This paper further examines the performance of a QLG code based SAC-OCDMA system with NAND and direct detection techniques. BER analysis was carried out for the proposed code and results were compared with existing MDW, RD and GMP codes. We demonstrate that the QLG code based system performs better in terms of cardinality, which is followed by improved BER. Numerical analysis reveals that for error free transmission (10-9), the suggested code supports approximately 170 users with code weight 4. Our results also conclude that the proposed code provides improvement in the code construction, cross-correlation and minimization of noises.

SOPC를 활용한 NG-SDH 망용 DP-PLL 제어기 설계에 관한 연구 (A Study on the DP-PLL Controller Design using SOPC for NG-SDH Networks)

  • 선권석;박민상
    • 융합신호처리학회논문지
    • /
    • 제15권4호
    • /
    • pp.169-175
    • /
    • 2014
  • NG-SDH 시스템은 광케이블 통하여 연결된 네트워크이다. 네트워크 동기제어기는 광전송시스템에서 데이터 동기에서 필수적이다. 본 논문에서 SOPC(system on a programmable chip) 설계 기술을 활용하여 네트워크 동기제어기를 설계한다. 설계를 위해 Altera사의 FPGA를 활용하고, FPGA안에는 32Bit CPU, DPRAM(dual port ram), 디지털 입출력포트, 송신 및 수신 프레이머, 위상차 검출기 등이 포함되어있다. 설계된 네트워크 동기제어기는 ITU-T G. 813에서 권고하는 동기기준(일시적인 응답에서의 MTIE, 원더 특성시 MTIE 및 TDEV, Holdover시 MTIE)을 만족함을 확인할 수 있다.

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

원격 감시와 제어를 위한 IDLC 채널뱅크의 설계 및 구현 (Design and Implementation of IDLC Channel Bank for Remote Monitoring and Control)

  • 하수호;한성화
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.409-412
    • /
    • 2000
  • In this paper we have implemented CH-MUX system which provides customers with various services, i.e. POTS, ISDN, digital leased line and so on, and supports not only UDLC but IDLC network configuration based on existing optical transmission facilities. Also the RCS equipment has been designed and implemented for remote monitoring and control of CH-MUXs. And then this paper has described IPC procedure and proposed other implemental methods of IPC channel. Service providers will be able to design and construct cost-effective access network with RCS and CH-MUX systems.

  • PDF