• Title/Summary/Keyword: optical eyes

Search Result 153, Processing Time 0.023 seconds

The Study for Refractive Error of the Westerner in 20s: North America Region (20대 서양인의 굴절이상에 대한 연구: 북미지역)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.97-101
    • /
    • 2009
  • Purpose: To assess the refractive state of the westerners (male: 44, female: 62) in twenties who visited the A optical shop at Seoul. Methods: The visual acuity test was performed by the objective and subjective method. Results: The emmetropia and myoptia were 35 and 177 eyes (83.49%), respectively. About 26.76% of tested males was ametropia. Myopia compound and myopia simple astigmatism were found in 60.56% and 12.68% of tested males, respectively. However, about 43.40% of tested females was ametropia. Myopia compound and myopia simple astigmatism were 49.06% and 7.55% were found in tested females, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -0.5D < spheric equivalent ${\leq}$ -2.00D was 35.02% of tested westerners, the -2.00D < spheric equivalent ${\leq}$ -6.00D was 60.45% and anything over the -6.00D was 4.53%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 59.82%, 26.78% and 13.40%, respectively. The average of pupillary distance in male (63.5${\pm}$2.4 mm) was greater than that in female (59.7${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription for the westerners in twenties by this research.

  • PDF

A Case of Unilateral Focal Pigmented Paravenous Retinochoroidal Atrophy (단안에 국소적으로 발현된 색소정맥옆망막맥락막 위축 1예)

  • Park, Hyo Song;Yang, Jong Yun;Park, Hyun Ju
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1190-1194
    • /
    • 2018
  • Purpose: We report a case of unilateral, focal, pigmented paravenous retinochoroidal atrophy (PPRCA). Case summary: A 46-year-old female visited our clinic in complaint of a vague problem with her right eye identified during a general medical examination. The visual acuity (without correction) of both eyes was 1.0. Slit-lamp examination of both eyes revealed no specific signs. Fundus examination of the right eye revealed focal, bony-spicule-shaped retinochoroidal atrophy with pigmentation along the course of the superior retinal vein. A fundus autofluorescence examination revealed principally hypofluorescence with some hyperfluorescence at the margin of the atrophic retinochoroidal lesion. Optical coherence tomography revealed mixed clumping and atrophy of the retinal pigment epithelium (RPE) layer and thinning of the choriocapillaris layer. Fluorescence angiography revealed a window defect and blockage at the site of the lesion (the fluorescent material did not enter the lesion). The site of the window defect was in correlation with the atrophic RPE region. The site of the blockage at lesion also matched with the site of the regional pigment clumping. No definite leakage was observed. Conclusions: To the best of our knowledge, this is the first case of unilateral focal PPRCA reported from Korea.

A Comparative Study on the Ametropias of Philippines and Koreans (한국인과 필리핀인의 굴절이상에 대한 연구)

  • Lee, Hark-Jun;Kwen, Man-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.477-482
    • /
    • 2012
  • Purpose: This study is aimed at finding the conditions of ametropia of adults in the Philippines and the South Korean. Methods: The study objects were 7,695(15,390 eyes) Koreans and 2,256(4,512 eyes) Philippines who visited optic clinics and took refraction test. The distributions of their hypermetropias and myopias about astigmatisms were examined, using the method of equivalent spherical power. When astigmatisms were marked in S-C, cylinder lens diopter and astigmatism axis, presbyopic additions and pupillary distances were analyzed by comparison respectively. Results: Among ametropias of Koreans myopias and hypermetropias were 93.69% and 6.31% respectively and about ametropias of Philippines myopia and hypermetropias were 73.43% and 26.57% respectively. As for spherical equivalent power about Koreans, the results showed that Koreans marked -3.352 D about myopia and Philippines marked -2.213 D about it. There is a gap of -1.139 D between them. About hypermetropia Koreans marked 1.147 D and Philippines, 1.251 D and their gap is 0.104 D. As for ametropia of Koreans there is 49.86% in middle myopia, 32.28% about low myopia, 11.55% about high myopia, and 5.54% about low hypermetropia, 0.75% about middle hypermetropia. As for it about Philippines there is 44.53% in low myopia, 25.11% about middle myopia, 3.79% high myopia and 23.03% low hypermetropia, and 3.51% low hypermetropia respectively. As for cylinder lens there is differences of 0.194 D and 0.22 D between Korean and Philippine for both sexes. Totally Koreans have higher cylinders of 0.175 D than Philippines. As for astigmatism, Koreans have direct astigmatism, inverse astigmatism, and oblique astigmatism in their suffering sequence. As for Philippines, they have direct astigmatism, inverse stigmatism, and oblique astigmatism in their abnormal sequence, and they have higher oblique stigmatism than Koreans. As for presbyopic addition, Philippines have higher distributions than Koreans, and 0.296 D is higher in average. As for pupillary distance, Koreans have longer distance of 0.97 mm in man and 0.63 mm in women than Philippines. Conclusions: As for ametropia, Koreans and Philippines have more myopias than hypermetropias, but Philippines have more rates of hypermetropias than Koreans. And Philippines have more presbyopic additions. Koreans have higher morbidity of inverse astigmatism, and Philippines have higher morbidity of oblique astigmatism comparatively. As for pupillary distance, Koreans have longer length in the body characteristics. This shows that geographical circumstances have much to do with refraction conditions of eyes.

Realtime Visibility Measurement Using Moving Area Filter and Image Contrast (이동영역 필터와 영상대비를 이용한 실시간 시정측정)

  • Kim, Bong-Keun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.3
    • /
    • pp.35-45
    • /
    • 2008
  • Realtime visibility measurement using camera is a new method which can collect some realtime visibility data similar to those of the human eyes, and can replace the existing methods using the expensive optical equipment. There have been a few attempts to measure visibility by extracting depth and three-dimensional structure under bad weather conditions. However, if there are many movements of objects in the image, these approaches seem to be inappropriate. In addition, the realtime visibility measurement will require a relatively simple and fast processing. Typically the contrast degrades exponentially in the bad weather. Therefore, in this paper we propose an easy and quick method that extract contrast from images using a moving area filter and measure visibility by mathematically modelling of the relationship between image contrast and visibility. The moving area filter is used for removing the area of the sky and moving objects that affect visibility measurement on images. The method proposed here can make possible not only realtime visibility measurement from images taken by CCD cameras, but also steady visibility measurement by using the moving area filter in case of much traffic on the road.

  • PDF

Rendering Method of Light Environment Based on Modeling of Physical Characteristic (물리적 특성 모델링에 기반한 라이팅 환경의 랜더링 기법)

  • Lee, Myong-Young;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.46-56
    • /
    • 2006
  • In this paper, we propose an improved reproduction algorithm for a realistic image of the real scene based on the optical characteristics of the light sources and the materials at the lighting environment. This paper is continuation of the previous study to improve the modeling method of the light sources and the materials and apply this to the real rear lamp of automobile. The backward ray tracing method is first used to trace the light ray from a light source, and also considers the physical characteristics of object surfaces and geometric properties of light radiation to estimate accurately the light energy incoming toward to human eyes. For experiments and verification of the proposed method, the simulation results are compared with the measured light stimuli. Accordingly, the simulation results show that the proposed algorithm can estimate light energy well and reproduce the visually similar image with a scene incident on a sight of viewer.

Experimental Study on Flicker Mitigation in VLC using Pseudo Manchester Coding (VLC에서 Pseudo Manchester Coding을 사용한 Flicker 최소화에 관한 실험 연구)

  • Ifthekhar, Md. Shareef;Le, Nam-Tuan;Jang, Yeong Min
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.116-120
    • /
    • 2014
  • Visible Light Communication is one of the promising technologies for wireless communication due to the possibility to use existing LED lightening infrastructure to transmit data. LED has the ability to turn on and off very fast enough that our human eyes can't recognize so it can be used to transmit data via visible light along with illumination. But it faces flicker problem due to the brightness discrepancies between '1' and '0' bit patterns inside a data frame. Various run length limited (RLL) coding scheme like Manchester code, 4B6B, 8B10B or VPPM can be used to solve flickering problem. So we propose pseudo Manchester codding which can transmit data without modifying LED modulator and demodulator circuit as well as solve flickering problem.

Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V (AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석)

  • Jeong, Min-Joo;Her, In-Sung;Kang, In-Cheol;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

Detection of Facial Direction using Facial Features (얼굴 특징 정보를 이용한 얼굴 방향성 검출)

  • Park Ji-Sook;Dong Ji-Youn
    • Journal of Internet Computing and Services
    • /
    • v.4 no.6
    • /
    • pp.57-67
    • /
    • 2003
  • The recent rapid development of multimedia and optical technologies brings great attention to application systems to process facial Image features. The previous research efforts in facial image processing have been mainly focused on the recognition of human face and facial expression analysis, using front face images. Not much research has been carried out Into image-based detection of face direction. Moreover, the existing approaches to detect face direction, which normally use the sequential Images captured by a single camera, have limitations that the frontal image must be given first before any other images. In this paper, we propose a method to detect face direction by using facial features such as facial trapezoid which is defined by two eyes and the lower lip. Specifically, the proposed method forms a facial direction formula, which is defined with statistical data about the ratio of the right and left area in the facial trapezoid, to identify whether the face is directed toward the right or the left. The proposed method can be effectively used for automatic photo arrangement systems that will often need to set the different left or right margin of a photo according to the face direction of a person in the photo.

  • PDF

A Study for Exact Spherical Diopter by Cross Cylinder Lens and Red·Green Card Method (크로스 실린더법과 적·녹검사를 이용한 정밀구면 굴절력에 관한 고찰)

  • Yoon, Kyounghan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.39-43
    • /
    • 1999
  • In this study, It obtained results that the exact spherical diopter to practice test by using Cross cyliner lens and Red Green Card method. In the test used to the 1750 eyes of middle and high school students. The results was as follows ; 1. Using Cross cylinder lens method, I tested a exact spherical diopter after accommodation. At -0.25 Dptr the ratio of spherical Dptr error limits were measured as 58% and at -0.75 Dptr they were oppeared as 1%, at -1.00 Dptr they are not measured. In this method, the error limits of exact spherical Dptr was 91% from 0 Dptr to -0.25 Dptr. 2. Using Red Green Card method, they were measured as 45% at -0.25 Dptr. and measured as 20% at -0.50 Dptr. From the result of these test, Cross cylinder lens method was a better detailed method than Red Green Card method.

  • PDF

Automatic Leather Quality Inspection and Grading System by Leather Texture Analysis (텍스쳐 분석에 의한 피혁 등급 판정 및 자동 선별시스템에의 응용)

  • 권장우;김명재;길경석
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.451-458
    • /
    • 2004
  • A leather quality inspection by naked eyes has known as unreliable because of its biological characteristics like accumulated fatigue caused from an optical illusion and biological phenomenon. Therefore it is necessary to automate the leather quality inspection by computer vision technique. In this paper, we present automatic leather qua1ity classification system get information from leather surface. Leather is usually graded by its information such as texture density, types and distribution of defects. The presented algorithm explain how we analyze leather information like texture density and defects from the gray-level images obtained by digital camera. The density data is computed by its ratio of distribution area, width, and height of Fourier spectrum magnitude. And the defect information of leather surface can be obtained by histogram distribution of pixels which is Windowed from preprocessed images. The information for entire leather could be a standard for grading leather quality. The proposed leather inspection system using machine vision can also be applied to another field to substitute human eye inspection.

  • PDF