A study on Installation of Facility Monitoring System in Computer Room's (전산실 기반설비감시시스템 구축에 관한 연구)

  • Choi, Woo-hyoung;Kim, Chang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.159-161
    • /
    • 2013
  • Surveillance system that can respond quickly in case of failure to detect various disorders that can occur for a temperature chamber, and fire extinguishing equipment, such as UPS, communication room, and computer room of enterprises and institutions operating in infrastructure, and to systematically study. Major telecommunications equipment and computational facilities to manage, operating in an environment of air conditioners work status, distribution panel and the UPS status and fault status, rapid notification system in case of fire is needed. By identifying the status and problems of disability surveillance on the periphery of the existing computer room's infrastructure management guidelines presented in the next future Conception and systematic surveillance system for staff to refer to when designing considerations associated with data center monitoring system the necessity of the various studies are presented.

  • PDF

A Loop Filter Size and Spur Reduced PLL with Two-Input Voltage Controlled Oscillator (두 개의 입력을 가진 VCO를 이용하여 루프필터와 스퍼 크기를 줄인 위상고정루프)

  • Choi, Young-Shig;Moon, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1068-1075
    • /
    • 2018
  • In this paper, a novel PLL has been proposed that reduces the size of the loop filter while suppressing spur by using a VCO with two inputs. Through the stability analysis according to the operating status, the PLL is designed to operate stably after the phase fixing. The capacitor of loop filter usually occupies larger area of PLL. It is a VCO that can reduce the size of the loop filter by increasing the effective capacitance of the capacitor through the simultaneous charge and discharge operation by two charge pumps and has two signals operating in opposite phases. The settling time of set to $80{\mu}s$ approximately by using a LSI(Locking Status Indicator) indicating the phase locking status. The proposed PLL is designed using a supply voltage of 1.8V and a $0.18{\mu}m$ CMOS process.

A study of Operational Scenarios for the Wireless Communications Based Train Control System (도시철도용 무선통신기반 열차제어시스템 운영시나리오 연구)

  • Yoon, Yong-Ki;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong;Kim, Yong-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.904-909
    • /
    • 2011
  • The development of train control system shall operate a series of processes like system designing, system production and system performance evaluation as a result of various requirements analysis presented in operation rules, operating guidelines for railway organizations etc, notified by the nation. Therefore, considering operation conditions, operation plan, linkage to railway network etc, the major document like system functional specifications, system development specifications, system test plans etc must be drawn up. In this paper we classify system operating scenarios required to prepare for system standard specification and system performance evaluation report of CBTC system for urban subways supporting unmanned automatic operation, and adjust each of the operating status.

  • PDF

Future Trend and Status of LCD OEM/ODM Operating Model

  • Pan, Po-Chuan;Koo, Horng-Show
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.858-862
    • /
    • 2005
  • The industry of LCD monitor and LCD/TV production is complicate, so there are several OEM/ODM companies concentrated on technical and professional skills. Brand name company establishes its own brand name, sells its own product, and reflects market request. Therefore, the main duty of brand name company is on sales and marketing. This article explains the operating flow on LCD monitor and LCD/TV industry, operating relationship between brand name company and OEM/ODM, and advantage and disadvantage on different points. Furthermore, future trend of LCD monitor and LCD/TV can be reviewed in the article.

  • PDF

Design and Requirement Analysis for Vehicle operating computer of Bimodal Tram (바이모달트램용 차량운영컴퓨터의 요구사항 분석 및 설계)

  • Lee, Kang-Won;Yoon, Hee-Taek;Kim, Gun-Kuk;Hwang, Wi-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1930-1935
    • /
    • 2008
  • Bimodal tram is able to run both general and special road. It has also the advantages of both public bus and subway which have the charateristics of easiness to approach and punctuality respectively. These advantages are accomplished by the cooperative communication between the control center and bimodal tram which is running with the fleet. This paper have investigated the requirement analysis and designing of the car operating computer system which have the functions of communication, broadcasting and display. car operating computer system communicates between bimodal tram and control center with wireless antenna. It can also transmit the location and status information of bimodal tram to control center for managing the bimodal tram fleet on road efficiently and economically.

  • PDF

A Fast Lock and Low Jitter Phase Locked Loop with Locking Status Indicator (Locking 상태 표시기를 이용한 저잡음 고속 위상고정 루프)

  • Choi Young-Shig;Han Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.582-586
    • /
    • 2005
  • This paper presents a new structure of Phase Locked Loop(PLL) which changes its loop bandwidth according to the locking status. The proposed PLL consists of a conventional PLL and, Locking Status Indicator(LSI). The LSI decides the operating bandwidth of loop filler. When the PLL becomes out of lock, the PLL increases the loop bandwidth and achieves fast locking. When the PLL becomes in-lock, this PLL decreases the loop bandwidth and minimizes phase noise output. The PLL can achieve fast locking and low phase noise output at the same time. Proposed PLL's locking time is less than $40{\mu}s$ and spur is 76.1dBc. It is simulated by HSPICE in a Hynix CMOS $0.35{\mu}m$ Process.

Development of VR Monitoring System for Gas Plant (가상현실을 이용한 가스플랜트의 VR Monitoring System 개발)

  • Suh, Myung-Won;Cho, Ki-Yang;Park, Dae-You
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.213-218
    • /
    • 2001
  • VR (Virtual reality) technologies have given engineers the ability to design, test, and evaluate engineering systems in a virtual environment. The virtual plant is the highlight of the application of the VR technology to plant engineering. Plant design, maintenance, control, management, operation are integrated in the virtual plant. The VR monitoring system including the concept of the virtual plant is developed to replace a current control room that has number of gages and warning lamps in two-dimensional panels which shows the operating status of a plant. The operating status of the plant is displayed in the VR monitoring system through the realistic computer graphics. Sophisticated, realistic and prompt control becomes possible. The VR monitoring system consists of advanced visualization, walk-through simulation and navigation. In the virtual environment, a user can navigate and interact with each component of a plant. In addition, the user can access the information by just clicking interesting component. The VR monitoring system is operated with various modules, such as (1) virtual plant constructed with Graphic Management System (GMS), (2) Touch & Tell System, and (3) Equipment DB System of Part. In order to confirm the usefulness of the VR monitoring system, a pilot gas plant which is currently being used for plant operator training is taken as application. The end of the paper gives an outlook on the future work and a brief conclusion.

  • PDF

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.