A Study on the Nonlinear Resistance Model of a F/L Operating in High Frequency (고주파 점등 형광램프의 비선형 저항 모델에 관한 연구)

  • 지철근;장우진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.2
    • /
    • pp.49-56
    • /
    • 1987
  • To save energy consumption, it is proposed to operate a discharge lamp with high frequency power. When designing a high frequency operating circuit containing a discharge lamp, the character of a lamp may be needed. And there are various methods to get and models for this. In this study, to present the volt-ampere character of a fluorescent lamp which gives a good saving effect, the nonlinear resistance model is suggested. And the validity of the model is verified by applying the model for the circuits with inductor ballast and capacifor ballast. This model, in contrast with the others, can be easily obtainable. And for comparison, the model using a modified Francis equation is examined. The method used in this study can be basically applied to the other discharge lamps. As a result, 1) Approximated 3rd order polynomial of nonlinear resistance model gives a good simulation result. 2) When operating in high frequency, the model using a modified Francis equation with constant coefficients can't be applied.

  • PDF

Design of Frequency Reconfigurable Antenna with the Vertically Stacked Dipole Structure (수직 적층형 다이폴 구조를 갖는 주파수 재구성 안테나 설계)

  • Jung, Young-Jin;Hong, Ic-Pyo;Eom, Soon-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • In this paper, the frequency reconfigurable antenna is proposed and designed. The proposed antenna is designed using the vertically stacked dipole structures and have the operating band for Cellular, PCS/WCDMA/Wibro/WiFi and WiMAX. The operating frequency band is selected by three pair of PIN diodes using the voltage difference between each dipole antenna and feeding transmission lines. The proposed antenna meets the required operating bandwidth and the maximum gain for each frequency band are measured as 6.3 dBi, 5.4 dBi and 5.8 dBi, respectively. The proposed antenna in this paper can be applied for the future mobile small base station or repeater antenna because this antenna can provide the small size and high gain features.

A Numerical Study on Sensitivity of Acoustic Response to Pressure Oscillations in Liquid Rocket Engine (압력진동에 대한 액체 로켓엔진의 음향 응답의 민감도에 관한 수치적 연구)

  • Sohn, Chae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.79-87
    • /
    • 2002
  • Acoustic responses to pressure oscillations in axisymmetric combustion chamber are numerically investigated to examine the qualitative trend of acoustic instability in liquid rocket engine. Chamber operating condition and excitation frequency of oscillating pressure are selected as exciting parameters of acoustic instability. Artificial perturbation is simulated by total-pressure oscillation with sine wave at chamber inlet. Many approximations and simplifications are introduced without losing the essence of acoustic pressure response. First, steady-state solution for each operating condition is obtained and next, transient analysis is conducted. Depending on operating condition and excitation frequency, the distinct response characteristics are brought. Weak-strength flames and high-frequency excitation tend to cause sensitive acoustic pressure response leading to unstable pressure field. These results are analyzed based on the correlation with acoustic pressure responses from the previous works adopting laminar flamelet model.

A constant power and optimal power factor drive of doubly fed induction generator (이중여자 유도발전기의 정출력.최적역률 운전)

  • 이우석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.31-38
    • /
    • 2000
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed, power, and power factor control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. The wind turbine speed and constant stator power were controlled by the rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, the rotor current was either less than or equal to the rated value. Accordingly, the optimal power factor can be selected relative to the permissible rated current at the rotor coil which controls the magnitude of the injected rotor voltage to the rotor according to a given rotor frequency. Consequently, it is possible to determine the optimal drive of a DFIG for wind power generation application.

  • PDF

A CMOS Phase-Locked Loop with 51-Phase Output Clock (51-위상 출력 클록을 가지는 CMOS 위상 고정 루프)

  • Lee, Pil-Ho;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.408-414
    • /
    • 2014
  • This paper proposes a charge-pump phase-locked loop (PLL) with 51-phase output clock of a 125 MHz target frequency. The proposed PLL uses three voltage controlled oscillators (VCOs) to generate 51-phase clock and increase of maximum operating frequency. The 17 delay-cells consists of each VCO, and a resistor averaging scheme which reduces the phase mismatch among 51-phase clock combines three VCOs. The proposed PLL uses a 65 nm 1-poly 9-metal CMOS process with 1.0 V supply. The simulated peak-to-peak 지터 of output clock is 0.82 ps at an operating frequency of 125 MHz. The differential non-linearity (DNL) and integral non-linearity (INL) of the 51-phase output clock are -0.013/+0.012 LSB and -0.033/+0.041 LSB, respectively. The operating frequency range is 15 to 210 MHz. The area and power consumption of the implemented PLL are $580{\times}160{\mu}m^2$ and 3.48 mW, respectively.

CS-PDM Series Resonant High Frequency Inverter for Copy Machine

  • Sugimura, Hisayuki;Eid, Ahmad Mohamad;Hiraki, Eiji;Kim, Sung-Jung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1066-1071
    • /
    • 2005
  • This paper presents the two lossless auxiliary inductors-assisted voltage source type half bridge (single ended push pull: SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimental ones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proved from the practical point of view.

  • PDF

Series Load Resonant High Frequency Inverter with ZCS-PDM Control Scheme for Induction-Heated Fusing Roller

  • Sugimura, Hisayuki;Kwen, Soon-Kurl;Koh, Kang-Hoon;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.415-420
    • /
    • 2005
  • This paper presents the two lossless auxiliary inductors-assisted voltage source type half bridge (single ended push pull: SEPP) series resonant high frequency inverter for induction heated king roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimental ones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proved from the practical point of view.

  • PDF

Analysis of Stability of PV System using the Eigenvalue according to the Frequency Variation and Requirements of Frequency Protection

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.480-485
    • /
    • 2012
  • Use of photovoltaic (PV) power generation system will become more widespread in the future due to anticipated cost reduction in PV technology. As the capacity of PV systems increases, a variation of power system frequency may prevent the stable output of PV system. However, the standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s rule does not include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various values of frequency are simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the setting of frequency protection is necessary to consider the stability of PV system.

A Study on the Optimum Design of Charge Pump PLL for High Speed and Fast Acquisition (고속동작과 빠른 Acquisition 특성을 가지는 Charge Pump PLL의 최적설계에 관한 연구)

  • Woo, Young-Shin;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.718-720
    • /
    • 1999
  • This paper describes a charge pump PLL architecture which achieves high frequency operation and fast acquisition. This architecture employs multi-phase frequency detector comprised of precharge type phase frequency detector and conventional phase frequency detector. Operation frequency is increased by using precharge type phase frequency detector when the phase difference is small and acquisition time is shortened by using conventional phase frequency detector and increased charge pump current when the phase difference is large. By virtue of this multi-phase frequency detector structure, the maximum operating frequency of 694MHz at 3.0V and faster acquisition were achieved by simulation.

  • PDF

Review on the reliability of low frequency responses of locally operating sensors (국내 지진센서의 저주파 응답의 신뢰성에 관한 고찰)

  • 박동희;연관희;장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.35-42
    • /
    • 2002
  • Frequency responses for most of the local seismic sensors in Korea have been roughly checked by mutual comparison of Fourier spectra of seismic records from accelerometer and seismometer, both of which are installed at the same location. Especially, because the frequency content of the seismic energy is usually above 1 Hz for local earthquakes, the reliability of low frequency response could have not been evaluated. Fortunately a recent large earthquake, Ms=7.2 on 02/06/29 containing dominant low frequency energy makes it possible to check the low frequency response of the seismic sensors, especially EpiSensor and JC-V100. Considering two types of sensor pairs, (STS-2 and EpiSensor, JC-V100 and EpiSensor), the low frequency response of EpiSensor is confirmed first by comparison with STS-2 which has proved low frequency response. Second, reliable low frequency limit of instrumentally corrected seismic data from JC-V100 data is estimated to be about 0.03 Hz by comparison with EpiSensor data.