• Title/Summary/Keyword: oneM2M Standard

Search Result 653, Processing Time 0.036 seconds

Electrochemical Etch-Stop Suitable for MEMS Applications

  • Chung, Gwiy-Sang;Kim, Sun-Chunl;Kim, Tae-Song
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.26-31
    • /
    • 2001
  • This paper presents the electrochemical etch-stop characteristics of single-crystal Si(001) wafers in tetramethyl ammonium hydroxide(TMAH):isopropyl alcohol(IPA):pyrazine solutions. The addition of pyrazine to TMAH:IPA solutions increased the etch rate of (100) Si, thus the etching time required by the etch-stop process shortened. The current-voltage(I-V) characteristics of n- and p-type Si in TMAH:IPA:pyrazine solutions were obtained, respectively. Open circuit potential(OCP) and passivation potential(PP) of n- and p-type Si, respectively, were obtained and applied potential was selected between n- and p-type Si PPs. The electrochemical etch-stop method was used to fabricate 801 microdiaphragms of 20 ${\mu}{\textrm}{m}$ thickness on a 5-inch Si wafer. The average thickness of fabricated 801 microdiaphragms on one Si wafer was 20.03 ${\mu}{\textrm}{m}$ and the standard deviation was $\pm$0.26 ${\mu}{\textrm}{m}$. The Si surface of the etch-stopped microdiaphragm was extremely flat with no noticeable taper or nonuniformity.

  • PDF

A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant (시흥정수장 막여과시설 시범운영)

  • 김한승;김충환;김학철;윤재경;안효원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

Characteristics of a PMOSFET Photodetector for Highly-Sensitive Active Pixel Sensor (고감도 능동픽셀센서를 위한 PMOSFET 광검출기의 특성)

  • Seo, Sang-Ho;Park, Jae-Hyoun;Lee, June-Kyoo;Wang, In-Soo;Shin, Jang-Kyoo;Jo, Young-Chang;Kim, Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.149-155
    • /
    • 2003
  • A PMOSFET photodetector for highly-sensitive active pixel sensor(APS) is presented. This sensor uses 5V power supply and has been designed and fabricated using I-poly and 2-metal $1.5{\mu}m$ CMOS technology. The feature of a PMOSFET photodetector is that the polysilicon gate of the PMOSFET was connected to n-well, in order to increase the photo sensitivity. The designed MOS photodetector has similar $I_{DS}-V_{DS}$ characteristics with a standard MOSFET. One dimensional image sensor with 16 pixels based on the PMOSFET photodetector has also been designed and fabricated. Unit pixel of the designed sensor consists of a PMOSFET photodetector and 4 NMOSFETs. Unit pixel area is $86{\mu}m{\times}90.5{\mu}m$ and its fill factor is about 12%.

Deep Learning based Estimation of Depth to Bearing Layer from In-situ Data (딥러닝 기반 국내 지반의 지지층 깊이 예측)

  • Jang, Young-Eun;Jung, Jaeho;Han, Jin-Tae;Yu, Yonggyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.3
    • /
    • pp.35-42
    • /
    • 2022
  • The N-value from the Standard Penetration Test (SPT), which is one of the representative in-situ test, is an important index that provides basic geological information and the depth of the bearing layer for the design of geotechnical structures. In the aspect of time and cost-effectiveness, there is a need to carry out a representative sampling test. However, the various variability and uncertainty are existing in the soil layer, so it is difficult to grasp the characteristics of the entire field from the limited test results. Thus the spatial interpolation techniques such as Kriging and IDW (inverse distance weighted) have been used for predicting unknown point from existing data. Recently, in order to increase the accuracy of interpolation results, studies that combine the geotechnics and deep learning method have been conducted. In this study, based on the SPT results of about 22,000 holes of ground survey, a comparative study was conducted to predict the depth of the bearing layer using deep learning methods and IDW. The average error among the prediction results of the bearing layer of each analysis model was 3.01 m for IDW, 3.22 m and 2.46 m for fully connected network and PointNet, respectively. The standard deviation was 3.99 for IDW, 3.95 and 3.54 for fully connected network and PointNet. As a result, the point net deep learing algorithm showed improved results compared to IDW and other deep learning method.

Study of the Effects of Sodium Chloride on Segregation-Distorter Action in D. melanogaster: 1. Theatment of Sodium Chloride on Whole Developmental Stages.

  • Kang, M.J.;Chung, Y.J.;Kim, K.J.
    • The Korean Journal of Zoology
    • /
    • v.13 no.1
    • /
    • pp.21-25
    • /
    • 1970
  • The present paper deals with the results of the experiments, in which the resistibility to NaCl in whole develomental stages is examined by the emergence rate and the effects of NaCl on the SD action in Drosophila melanogaster. The four SD strains and one mutant strain(cn bw)are used and NaCl media are prepared y adding NaCl at a concentration of 1.0M, 0.7M, 0.5M, 0.3M, 0.1M, and 0.0M to the standard media for the present investigations. The results are given below. 1. The emergence rate (resistibility to NaCl) is not significantly different among strains but strikingly different among concentrations of NaCl. 2. The emergence rate decreases as the concentration of NaCl increases; the four SD strains are considerably resistible to the NaCl from a concentration of 0.0M to 0.3M but are susceptible from 0.5M or higher concentrations of NaCl. 3. No eggs are hatched from the culture media containing a concentration of 1.0M NaCl. This suggests that the SD strains are not resistible to NaCl at a concentrations of 1.0M or higher. 4. The difference in k values is not signficant among strains and also among concentrations of NaCl. Thus the SD action is not affected as far as once emerged from the culture media whether containing NaCl or not.

  • PDF

A Study on the Standard Scale of Measuring a Block of Kyongju, the Capital of the Silla Dynasty (신라(新羅) 왕경(王京) 경주(慶州)의 토지(土地) 분할(分割) 척도(尺度)에 관한 고찰(考察))

  • Woo, Seong-Hoon;Lee, Sang-Hae
    • Journal of architectural history
    • /
    • v.6 no.1 s.11
    • /
    • pp.9-25
    • /
    • 1997
  • The purpose of this study is to examine the standard scale of measuring a block of Kyongju(慶州), the Capital of the Silla Dynasty(B.C.57${\sim}$A.D.935). Through the study, it is clarified that 1). the block of Kyongju city is planned and divided by using the eight-Zhou-foot(周尺) as a standard scale, which is equivalent to the length of one-bo(보(步); 2). the distance between the center of the streets is around 100 bo and the width of the block is around 90 bo; 3). the distance between the streets is very near to the distance 167.054m of Jing-tian-zhi(井田制), which supports the use of Zhou-foot as a standard scale. As a result, it can be maintained that the city planning of Kyongju is related to that the Jing-tian-zhi of the Zhou Dynasty and the standard scale of measuring a block of Kyongju us executed by using the eight-Zhou-foot standard scale.

  • PDF

The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET (FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향)

  • Park, Young-Jae;Bang, Seong-Ae;Lee, Seung-Min;Kim, Sang-Un;Ko, Gil-Man;Lee, Kyung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

  • PDF

Medication Reminder System for Smart Aging Services Using IoT Platforms and Products

  • Sung, Nak-Myoung;Yun, Jaeseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.107-113
    • /
    • 2017
  • In this paper, we propose a medication reminder system using IoT platforms and products to help old adults keep track of their medication schedule, one of 10 Korean instrumental activities in daily living (K-IADL). An interworking architecture based on the oneM2M standard platform is designed to allow various IoT products to be connected each other through interworking proxy entities. A prototype system for the medication reminder service is developed, which consists of a pair of off-the-shelf pill bottle and container box embedded with an NFC tag and reader respectively, three types of actuators including a LIFX LED lightbulb, Musaic speaker, Microsoft Band 2, and smartphone applications. The experiment shows that our medication reminder system can make alarms for old adults to take their pills appropriately considering where they are and when they have food inferred from data collected from sensors including ultrasonic sensor and rice cooker, fostering them to keep their medication routine.

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.

A Basic Study on Feasibility Analysis for Solar Energy Facility using Standard Broiler House Roof (표준육계사의 지붕을 활용한 태양에너지 설비 타당성 분석에 관한 기초 연구)

  • Kim, Jin-Hyun;Jung, Sung-Jin;Kim, Tae-Wook;Choi, Jun-Hak;Ha, Yu-Shin
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.57-65
    • /
    • 2014
  • In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.