• 제목/요약/키워드: office room

검색결과 288건 처리시간 0.031초

인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로- (A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China-)

  • 백승경;이승훈
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구 (A Study on Improvement According to Korea and China Evacuation Laws in Office Building)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

사무실, 회의실, 휴게실, OA실의 조명 시나리오에 따른 감성평가 비교 연구 - 동·서양인을 대상으로 - (Comparative Study of Emotion Evaluation Based on Lighting Scenario of Office, Meeting Room, Lounge, and OA Room)

  • 이민진;조미령;고재규;김주현
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.23-35
    • /
    • 2013
  • In this study, we collected the emotion vocabulary novel related to the LED system light emotion and the existing terms through previous research, targeting professionals and KJ method, we selected emotion term of 35 kinds. Targeting this east Foreigner, we compared the emotion evaluation by changing the lighting elements in accordance office, meeting room, lounge, the OA room different behavior patterns. The results, showing the difference between the results of emotion existing research generally derived factors three axes "future, functionality" See, "stability", "activity". As a result of the comparison of the emotion of the East and the West, the Oriental, functional aspects of the LED system light of space office, meeting room, lounge is drawn most, On the other hand, Westerners, come up, stable surface shows the difference in accidentally. Based on these results, the future, and tries to utilized to evaluate the emotion reaction of the illumination elements each Test-Bed actual.

협업설계를 위한 가상업무공간 구축에 관한 연구 (A Conceptual Framework of Virtual Workplace for Collaborative Design)

  • 정다운;김미정;김현경;조명은;이현수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2000년도 학술발표대회논문집
    • /
    • pp.159-165
    • /
    • 2000
  • The purpose of this study is to develop a virtual office design in a 3D digital environment which involves a consideration of what people do and need in a virtual workplace and then translating that into a virtual environment for collaborative design. Areas in a virtual design office are defined according to different uses or activities in a physical office. The workplace includes a hall and information desk, working area, a conference room, a library, an entertainment room and a management room. It is important to define areas considering shared territory and personal territory. Communication and collaboration amonge designers are provided over the World Wide Web.

  • PDF

모형실과 실공간에서의 환기성능에 관한 실험적 연구 (An Experimental Study on the Ventilation performance in a Test Chamber and Office Room)

  • 윤석구;구재현;현옥천;한정균;이재근;조민철;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.520-525
    • /
    • 2000
  • This research is to analyze the ventilation performance of mechanical ventilation systems for indoor air quality control and management. A ventilation performance with supply sites is evaluated in a test model chamber and office room. A $CO_2$ gas as a tracer gas is used to measure the ventilation performance. The ventilation performance is found to increase with increased the ventilation rate. The ventilation performance is analysed with 55% at the supply air of 570 lpm and with 20% at the supply air of 100 lpm in a test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570 lpm in office room.

  • PDF

충남교육청 소속 공공도서관의 공간혁신에 관한 연구 (A Study on the Space Innovation of Public Libraries Belonging to Chungcheongnam-do Office of Education)

  • 임정훈;오형석;이병기
    • 한국도서관정보학회지
    • /
    • 제52권4호
    • /
    • pp.103-126
    • /
    • 2021
  • 본 연구는 충청남도교육청 소속 19개 공공도서관을 대상으로 교육·문화복합공간으로서의 도서관 재구조화 방안을 제안하고자 하였다. 이를 위해 국내외 공공기관 복합화 시설의 사례 조사, 이용자 설문조사 등을 실시하였다. 그 결과 미래 공공도서관이 갖추어야 할 공간으로 배우는 공간(종합자료실, 테마 자료 탐구실, 미래교실, 블렌디드 러닝센터, STEAM 교육실, 원격강의학습실), 표현하는 공간(포이어, 메이커 룸, 디지털 매체 창작실, 원격강의제작실), 나누는 공간(동아리·모둠학습실, 웰빙 복합문화공간, 생활·편의공간, 휴게실·브라우징), 즐기는 공간(퍼포먼스·생각 놀이터, 유아·어린이 자료실, 디지털 가상체험실, 특화 알코브실, 야외독서실) 등으로 구분하여 공간 재구조화 전략을 제시하였다. 또한, 건축 규모, 장서 규모, 서비스 및 공간 수준 등을 고려하여 선도모형, 기본모형, 이음터 모형, 최소모형 등 도서관별로 특화된 교육청 소속 공공도서관의 재구조화 모형을 제안하였다.

옥내(屋內)의 온도(溫度), 상대습도(相對濕度)와 목재(木材) 평형함수율(平衡含水率)의 연중(年中) 변이(變異) (Annual Variation in Temperature, Relative Humidity and Equilibrium Moisture Content of Wood in Indoor)

  • 정희석;이남호
    • 한국산림과학회지
    • /
    • 제83권4호
    • /
    • pp.540-544
    • /
    • 1994
  • 중부 지방에서 옥내의 목재 사용 4장소별로 기후치평형함수율은 온도와 상대습도를 근거하여 계산하고 실측평형함수율은 더그러스 퍼와 상수리나무 등 7수종의 기건 시험편을 1년간 공시하여 측정하였다. 조사된 각 장소의 연간 평균 온도과 상대습도는 아파트 안방이 $23.3^{\circ}C$와 54.9%, 아파트 거실은 $22.4^{\circ}C$와 59.5%, 사무실은 $20.1^{\circ}C$와 57.0%, 단독주택의 거실은 $19.4^{\circ}C$와 64.0%이었다. 년간 평균 기후치평형함수율과 실측평형함수율은 아파트 안방은 각각 10.2%와 9.7%, 아파트 거실은 각각 11.1%와 10.2%, 사무실은 각각 10.7%와 10.4% 그리고 단독주택의 거실은 각각 12.1%와 12.5%이었다. 카사이의 실측평형함수율은 전체 평균치보다 약간 컸었고 버즘나무와 아피통은 약간 적었다.

  • PDF

대학 내 사무실의 스피치 프라이버시 측정 및 평가 (Measurement and evaluation of speech privacy in university office rooms)

  • 임재섭;최영지
    • 한국음향학회지
    • /
    • 제38권4호
    • /
    • pp.396-405
    • /
    • 2019
  • 본 논문에서는 대학 내 밀폐형 사무실의 SPC(Speech Privacy Class) 값을 측정하고 평가하였다. 대학 캠퍼스 내 3곳의 건물에 위치한 5곳 대상공간에서 실간 음압레벨차이(Level Difference, LD)와 수음실의 암소음 레벨($L_b$)을 각각 측정하였다. 5곳 대상공간은 모두 인접실과 복도가 인접해있다. SPC값을 도출하기 위해 필요한 LD값과 기존의 차음성능 측정방법인 투과손실(Transmission Loss, TL)을 함께 측정하여 비교하였다. 측정결과, 5곳 대상공간은 SPC 최소 기준치인 70을 만족하지 못하였다. 5곳 대상공간의 평균 $L_b$값은 29.2 dB이며 SPC 최소 기준치를 만족하기 위해서는 LD값이 41 dB 이상이어야 한다. SPC 최소 기준치를 만족하기 위해서 1/3옥타브밴드 160 Hz ~ 5000 Hz 주파수대역에서 평균 TL값은 40 dB 이상이 되도록 음향설계가 이루어져야 한다. LD값에 가장 큰 영향을 미치는 인자는 음원실과 수음실 간 인접벽체의 개구부 유무이다. 따라서 인접벽체에 개구부가 존재할 경우 차음성능이 높은 재료로 개구부를 대체하여 적절한 SPC값을 만족할 수 있다.

일사차단용 설비를 이용한 냉방 에너지 절약 방안 (Cooling Energy Saving System using Solar Heat Protection Dvices)

  • 정기범;최상곤
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

사무소 건물의 공조설비소음 특성 (The Characteristics of HVAC Noise in Office Buildings)

  • 도영주;김동규;김흥식
    • 한국음향학회지
    • /
    • 제8권1호
    • /
    • pp.59-66
    • /
    • 1989
  • 공조설비소음의 특성을 파악하기 위하여 서울의 도심에 위치한 고층 사무소 건물을 대상으로 송풍기의 파워레벨과 취출구를 통한 실내소음레벨을 측정하였다. 또한 공조설비소음이 문제시되는 건물에 흡음챔버와 사이드브랜치를 설치하여 소음기의 감음성능을 평가하였다. 연구의 결과, 실내소음레벨은 송풍기 발생소음의 영향으로 500Hz 이하의 저주파수 대역에서 ISO의 허용 기준치인 NR40을 초과하였으며 흠음챔버는 넓은 대역의 주파수, 사이드브랜치는 특정공명주파수에서 감음효과가 크게 나타났다.

  • PDF