• Title/Summary/Keyword: office room

Search Result 288, Processing Time 0.035 seconds

A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China- (인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로-)

  • Back, Seong-Kyung;Lee, Seung-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

A Study on Improvement According to Korea and China Evacuation Laws in Office Building (오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

Comparative Study of Emotion Evaluation Based on Lighting Scenario of Office, Meeting Room, Lounge, and OA Room (사무실, 회의실, 휴게실, OA실의 조명 시나리오에 따른 감성평가 비교 연구 - 동·서양인을 대상으로 -)

  • Lee, Min-Jin;Cho, Mee-Ryoung;Ko, Jae-Kyu;Kim, Ju-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.23-35
    • /
    • 2013
  • In this study, we collected the emotion vocabulary novel related to the LED system light emotion and the existing terms through previous research, targeting professionals and KJ method, we selected emotion term of 35 kinds. Targeting this east Foreigner, we compared the emotion evaluation by changing the lighting elements in accordance office, meeting room, lounge, the OA room different behavior patterns. The results, showing the difference between the results of emotion existing research generally derived factors three axes "future, functionality" See, "stability", "activity". As a result of the comparison of the emotion of the East and the West, the Oriental, functional aspects of the LED system light of space office, meeting room, lounge is drawn most, On the other hand, Westerners, come up, stable surface shows the difference in accidentally. Based on these results, the future, and tries to utilized to evaluate the emotion reaction of the illumination elements each Test-Bed actual.

A Conceptual Framework of Virtual Workplace for Collaborative Design (협업설계를 위한 가상업무공간 구축에 관한 연구)

  • 정다운;김미정;김현경;조명은;이현수
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2000.11b
    • /
    • pp.159-165
    • /
    • 2000
  • The purpose of this study is to develop a virtual office design in a 3D digital environment which involves a consideration of what people do and need in a virtual workplace and then translating that into a virtual environment for collaborative design. Areas in a virtual design office are defined according to different uses or activities in a physical office. The workplace includes a hall and information desk, working area, a conference room, a library, an entertainment room and a management room. It is important to define areas considering shared territory and personal territory. Communication and collaboration amonge designers are provided over the World Wide Web.

  • PDF

An Experimental Study on the Ventilation performance in a Test Chamber and Office Room (모형실과 실공간에서의 환기성능에 관한 실험적 연구)

  • Yoon, Suk-Goo;Ku, Jae-Hyun;Yun, Ok-Chun;Han, Jung-Gun;Lee, Jae-Keum;Cho, Min-Chul;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.520-525
    • /
    • 2000
  • This research is to analyze the ventilation performance of mechanical ventilation systems for indoor air quality control and management. A ventilation performance with supply sites is evaluated in a test model chamber and office room. A $CO_2$ gas as a tracer gas is used to measure the ventilation performance. The ventilation performance is found to increase with increased the ventilation rate. The ventilation performance is analysed with 55% at the supply air of 570 lpm and with 20% at the supply air of 100 lpm in a test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570 lpm in office room.

  • PDF

A Study on the Space Innovation of Public Libraries Belonging to Chungcheongnam-do Office of Education (충남교육청 소속 공공도서관의 공간혁신에 관한 연구)

  • Lim, Jeong-Hoon;Oh, Hyoung-Seok;Lee, Byeong-Ki
    • Journal of Korean Library and Information Science Society
    • /
    • v.52 no.4
    • /
    • pp.103-126
    • /
    • 2021
  • This study aims to propose a plan to restructure libraries as a complex space for education and culture for 19 public libraries belonging to the Chungcheongnam-do Office of Education. For the purpose of this, case surveys and user surveys of complex facilities of domestic and foreign public institutions were conducted. Based on the findings, a space restructuring strategy was suggested by dividing the library space into the following ways: a space to learn (a comprehensive data room, a theme data inquiry room, a future classroom, a blended learning center, a STEAM training room, and an online lecture learning room), a space to express (a foyer, a maker room, a digital media creation room and an online lecture production room), a space to share (a club room, a group study room, a well-being complex culture space, a convenient living space, rest area, and a browsing area), and a space to enjoy (a performance-thought playground, infant and child archives, a digital virtual experience room, a specialized alcove room, and an outdoor reading room). In addition, a restructuring model of public libraries belonging to the Office of Education was proposed, such as a leading model, a basic model, a joint model, and a minimum model, in consideration of the size of the building, the size of the library, and the level of service and space.

Annual Variation in Temperature, Relative Humidity and Equilibrium Moisture Content of Wood in Indoor (옥내(屋內)의 온도(溫度), 상대습도(相對濕度)와 목재(木材) 평형함수율(平衡含水率)의 연중(年中) 변이(變異))

  • Jung, Hee-Suk;Lee, Nam-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.540-544
    • /
    • 1994
  • Equilibrium moisture contents(EMC) were calculated based on temperature and relative humidity of atmosphere and actual EMCs were measured at intervals of ten days in previous air-dried wood samples for seven different species including Douglas fir and oaks in four indoor locations in central region for one year. Mean annual air temperature and relative humidity were $23.3^{\circ}C$ and 54.9% in bedroom, $22.4^{\circ}C$ and 59.5% in living room of apartment, $20.1^{\circ}C$ and 57.0% in office room and 19.4 and 64.0% in living room of tile-roofed house, respectively. Mean annual calculated and actual EMCs were 10.2 and 9.7% in bedroom, 11.1 and 10.2% in living room of apartment, 10.7 and 10.4% in office room, and 12.1 and 12.5% in living room of tile-roofed, house, respectively. Actual EMC of kasai were higher than average value of EMC for seven species. However, those of sycamore and apitong were lower than average value.

  • PDF

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Cooling Energy Saving System using Solar Heat Protection Dvices (일사차단용 설비를 이용한 냉방 에너지 절약 방안)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

The Characteristics of HVAC Noise in Office Buildings (사무소 건물의 공조설비소음 특성)

  • Do, Young-Ju;Kim, Dong-Gyu;Kim, Heung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 1989
  • This study aims to provide the basic data useful in assessing indoor-noise and designing sound devices in office buildings of HVAC system. The measurements of HVAC noise were carried out in office room and mechanical room. The performance of absorptive chamber and side branch was also estimated in the office buildings which have HVAC noise problems. The results of experiments show that the NR value of indoor HVAC noise is rather higher than that of ISO recommendations at the frequencies below 500Hz. In addition, the results indicated that the absorptive chamber attenuates noise over broad band frequencies and side branch reduces noise at the special resonant frequency.

  • PDF