• 제목/요약/키워드: normal connection

검색결과 258건 처리시간 0.029초

Finite element development of a Beam-column connection with CFRP sheets subjected to monotonic and cyclic loading

  • Rahimipour, Arash;Hejazi, Farzad;Vaghei, Ramin;Jaafar, Mohd Saleh
    • Computers and Concrete
    • /
    • 제18권6호
    • /
    • pp.1083-1096
    • /
    • 2016
  • Beam-column joints are recognized as the weak points of reinforcement concrete frames. The ductility of reinforced concrete (RC) frames during severe earthquakes can be measured through the dissipation of large energy in beam-column joint. Retrofitting and rehabilitating structures through proper methods, such as carbon fiber reinforced polymer (CFRP), are required to prevent casualties that result from the collapse of earthquake-damaged structures. The main challenge of this issue is identifying the effect of CFRP on the occurrence of failure in the joint of a cross section with normal ductility. The present study evaluates the retrofitting method for a normal ductile beam-column joint using CFRP under monotonic and cyclic loads. Thus, the finite element model of a cross section with normal ductility and made of RC is developed, and CFRP is used to retrofit the joints. This study considers three beam-column joints: one with partial CFRP wrapping, one with full CFRP wrapping, and one with normal ductility. The two cases with partial and full CFRP wrapping in the beam-column joints are used to determine the effect of retrofitting with CFRP wrapping sheets on the behavior of the beam-column joint confined by such sheets. All the models are subjected to monotonic and cyclic loading. The final capacity and hysteretic results of the dynamic analysis are investigated. A comparison of the dissipation energy graphs of the three connections shows significant enhancement in the models with partial and full CFRP wrapping. An analysis of the load-displacement curves indicates that the stiffness of the specimens is enhanced by CFRP sheets. However, the models with both partial and full CFRP wrapping exhibited no considerable improvement in terms of energy dissipation and stiffness.

RIBAUCOUR TRANSFORMATIONS ON LORENTZIAN SPACE FORMS IN LORENTZIAN SPACE FORMS

  • Park, Joon-Sang
    • 대한수학회지
    • /
    • 제45권6호
    • /
    • pp.1577-1590
    • /
    • 2008
  • We study Ribaucour transformations on nondegenerate local isometric immersions of Lorentzian space forms into Lorentzian space forms with the same sectional curvatures which have flat normal bundles. They can be associated to dressing actions on the solution space of Lorentzian Grassmannian systems.

As-built modeling of piping system from terrestrial laser-scanned point clouds using normal-based region growing

  • Kawashima, Kazuaki;Kanai, Satoshi;Date, Hiroaki
    • Journal of Computational Design and Engineering
    • /
    • 제1권1호
    • /
    • pp.13-26
    • /
    • 2014
  • Recently, renovations of plant equipment have been more frequent because of the shortened lifespans of the products, and as-built models from large-scale laser-scanned data is expected to streamline rebuilding processes. However, the laser-scanned data of an existing plant has an enormous amount of points, captures intricate objects, and includes a high noise level, so the manual reconstruction of a 3D model is very time-consuming and costly. Among plant equipment, piping systems account for the greatest proportion. Therefore, the purpose of this research was to propose an algorithm which could automatically recognize a piping system from the terrestrial laser-scanned data of plant equipment. The straight portion of pipes, connecting parts, and connection relationship of the piping system can be recognized in this algorithm. Normal-based region growing and cylinder surface fitting can extract all possible locations of pipes, including straight pipes, elbows, and junctions. Tracing the axes of a piping system enables the recognition of the positions of these elements and their connection relationship. Using only point clouds, the recognition algorithm can be performed in a fully automatic way. The algorithm was applied to large-scale scanned data of an oil rig and a chemical plant. Recognition rates of about 86%, 88%, and 71% were achieved straight pipes, elbows, and junctions, respectively.

해커의 공격에 대한 지능적 연계 침입방지시스템의 연구 (A Study of the Intelligent Connection of Intrusion prevention System against Hacker Attack)

  • 박대우;임승린
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권2호
    • /
    • pp.351-360
    • /
    • 2006
  • 기존의 침입차단시스템과 침입탐지시스템의 단점을 개선할 수 있는 지능적 연계 침입방지시스템을 제안한다. 제안된 보안 시스템은 공격 검출, 공격 우회로 설정 및 통신량 대역 확보, 다른 연계 보안 시스템에 공격 정보 홍보, 내부 IPS에서의 필터 생성, 차단 필터링의 즉각적인 업데이트, 공격 패킷 차단 및 서비스와 포트 차단 설정이다. 스위치 타입 구현과 동적 재설정 메모리들을 통해 새로운 보안 규칙과 패킷 필터링을 실시간으로 교환하고 패킷을 처리한다. 네트워크 성능 실험에서 해커의 공격인 2.5 Gbs의 DDoS, SQL Stammer, Bug bear, Opeserv worm 등에 대한 공격검출이 실시간으로 이루어졌다. 이를 갱신하는 보안 정책 알고리즘의 즉각적인 갱신의 결과로 정상적인 패킷 외에 해커의 공격으로 인한 패킷은 차단되었고, 트래픽은 감소되어, 정상적인 내부와 외부 네트워크 트래픽의 잔여 대역폭을 확보하였다.

  • PDF

나사조임토크에 따른 전선접속부의 열적특성에 관한 연구 (A Study on the Thermal Characteristics of Wire Connection Part Depending on the Screw Torque)

  • 김시국;지승욱;박상민;이춘하
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.82-88
    • /
    • 2012
  • 본 논문은 나사조임 단자대에 접속되는 전선접속부의 나사조임토크에 따른 열적특성을 분석하고자, 나사조임토크를 KS C 2625에서 규정한 정상조임토크와 시공불량 및 경년변화 등의 원인으로 인해 나사조임의 풀림으로 발생될 수 있는 이상조임토크를 실험의 변수로 하였다. 이때, 정상조임토크와 이상조임토크에 동일한 부하를 인가한 후, 열화상카메라를 이용하여 전선접속부의 열적특성을 측정한 후 비교 분석하였다. 도출된 결과를 바탕으로 향후 전기안전점검 시 단자대 접속개소의 조임토크 불량으로 인한 발열을 사전에 감지하고, 전기화재의 위험성이 나타날 가능성을 최소화 할 수 있는 대책자료로 활용하고자 한다.

구름접촉에 의한 SM55C의 마멸 거동 (Wear behavior of SM55C steel by rolling contact)

  • 박범수;채영훈;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.240-247
    • /
    • 2002
  • The rolling wear behavior of SM55C is investigated under lubrication. This is a comparative tribological behavior of heat treatment effect for SM55C. Rolling wear test method is used for Ball-on-disk type. Specimens can be classified into two main groups: as-annealing and non-annealing. As result of wear behavior, flanking initial time of non-annealing specimen keep at retard but it have not under high normal load. One of the notable features of annealing specimen is steady flanking initial time for a normal load in this experiment. Failure mechanism of SM55C is due to the fatigue wear such like flanking, pitting etc.. Flanking leads to abruptly fracture of worn surface. Fracture mechanism has a connection with normal load and polishing direction of specimens.

  • PDF

PSEUDO-HERMITIAN MAGNETIC CURVES IN NORMAL ALMOST CONTACT METRIC 3-MANIFOLDS

  • Lee, Ji-Eun
    • 대한수학회논문집
    • /
    • 제35권4호
    • /
    • pp.1269-1281
    • /
    • 2020
  • In this article, we show that a pseudo-Hermitian magnetic curve in a normal almost contact metric 3-manifold equipped with the canonical affine connection ${\hat{\nabla}}^t$ is a slant helix with pseudo-Hermitian curvature ${\hat{\kappa}}={\mid}q{\mid}\;sin\;{\theta}$ and pseudo-Hermitian torsion ${\hat{\tau}}=q\;cos\;{\theta}$. Moreover, we prove that every pseudo-Hermitian magnetic curve in normal almost contact metric 3-manifolds except quasi-Sasakian 3-manifolds is a slant helix as a Riemannian geometric sense. On the other hand we will show that a pseudo-Hermitian magnetic curve γ in a quasi-Sasakian 3-manifold M is a slant curve with curvature κ = |(t - α) cos θ + q| sin θ and torsion τ = α + {(t - α) cos θ + q} cos θ. These curves are not helices, in general. Note that if the ambient space M is an α-Sasakian 3-manifold, then γ is a slant helix.