• Title/Summary/Keyword: needle biopsy

Search Result 462, Processing Time 0.021 seconds

Interpretation of Image-Guided Biopsy Results and Assessment (영상유도하 조직검사의 해석과 판정)

  • Su Min Ha;Jung Min Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.361-371
    • /
    • 2023
  • The success of image-guided breast biopsy depends on the biopsy method, needle selection, and appropriate technique based on the accurate judgment by the radiologist at biopsy. However, insufficient or inappropriate sampling of specimens may result in false-negative results or pathologic underestimation. Therefore, image-pathology concordance assessments after biopsy are essential for appropriate patient management. Particularly, the assessment of image-pathology concordance can avoid false-negative reports of breast cancer as a benign pathology. Therefore, this study aimed to discuss factors that impact the accurate interpretation of image-guided breast biopsy along with the appropriate assessments.

A Study on the Ceramic Coating of Biopsy Needle (조직생검용 Needle의 세라믹 코팅에 관한 연구)

  • Cho, Sung-Man;Chung, Hyup-Jae;Kim, Man-Tae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.121-126
    • /
    • 2009
  • Stainless steel 316L (STS 316L) is widely used as a material of biopsy needle. However it has a side effect that tissue can be damaged by electrochemical operation between tissue and STS 316L. Many studies have been made on the ceramic coating of biopsy needle to reduce the side effect. In this study, STS 316L was coated with three bioceramics, $Al_2O_3$, $SiO_2$ and $ZrO_2$ using a RF magnetron sputtering method. The effects of ceramic coating on the electrical conductivity and coating strength of ceramic-coated STS 316L were investigated. The results showed that the electrical conductivity of ceramic-coated STS 316L was much lower than that of uncoated STS 316L. The coating strength of $ZrO_2$-coated STS 316L was 30% and 70% higher, respectively than those of $Al_2O_3$-coated STS 316L and $SiO_2_3$-coated STS 316L.

Hematoma-Filled Pneumatocele after CT-Guided Percutaneous Transthoracic Needle Lung Biopsy: Two Case Reports (컴퓨터단층촬영 유도 경피적 바늘 생검 이후에 발생한 혈종으로 채워진 기종: 두 건의 증례 보고)

  • Se Ri Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.311-317
    • /
    • 2023
  • CT-guided percutaneous transthoracic needle biopsy (PTNB) plays a key role in the diagnosis of pulmonary abnormalities. Although the procedure is considered safe and effective, there exists a potential for complications, such as pneumothorax, hemorrhage, hemoptysis, air embolism, and tumor seeding. However, pneumatoceles after CT-guided PTNB have been rarely reported. Herein, we report two cases of pneumatoceles that developed immediately after PTNB for primary lung cancer. A pneumatocele filled with hematoma should be considered in cases with a newly developed nodule along the needle tract during short-term follow-up CT after PTNB.

Ultrasound-guided Core Needle Biopsy in Diagnosis of Soft Tissue Masses (연부조직 종물의 진단에서 초음파 유도하 중심부 침생검)

  • Kim, Jeung-Il;Youn, Myung-Soo;Cheon, Sang-Jin;Choi, Gyung-Un;Lee, Tae-Hong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.113-119
    • /
    • 2004
  • Purpose: To determine the utility of sonographically guided percutaneous core needle biopsy to diagnose musculoskeletal soft tissue masses. Methods: A prospective study was performed in 55 patients referred for image-guided needle biopsy of primary or recurrent soft tissue masses and bone lesion or suspected solitary metastasis with extraosseous masses. Tissue samples were obtained with a 14-gauge or 18-gauge cutting needle coupled to an automated biopsy device under local anesthesia and sonographic guidance. Statistical analysis was based on 49 biopsies confirmed by successful clinical treatment (11 cases) or surgical resection (38 cases). Results: An accurate diagnosis was obtained in 47 (97%) of 49 biopsies; sensitivity was 95%, and specificity was 100%. The method did not yield sufficient tissue to establish a diagnosis in 6 cases. Considering all 55 biopsies, high-quality specimens were obtained in 87%. There were no serious complications. Conclusions: Sonographically guided core needle biopsy is accurate and safe, in soft tissue masses and bone tumors with extraosseous masses in the appendicular skeleton. In such patients, the sonographically guided procedure is the most prompt and effective method for obtaining tissue samples.

  • PDF

Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images (연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가)

  • Lee, So Hee;Kim, Jong Un;Lee, Su Yeol;Ryu, Jeong Won;Choi, Dong Hyuk;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

A Case of Orbital Meningioma Diagnosed by Fine Needle Aspiration Biopsy (세침흡인 생검으로 진단된 안와 수막종 - 1예 보고 -)

  • Lee, Ji-Shin;Kim, Kyung-Soo;Lee, Min-Cheol;Park, Chang-Soo;Juhng, Sang-Woo
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.2
    • /
    • pp.176-179
    • /
    • 1994
  • Orbital meningioma is a rare neoplasm that, even when suspected by CT or echographic examination, requires careful histologic study for precise identification. Fine needle aspiration(FNA) biopsy has become the diagnostic technique of choice in recent years for investigating orbital masses. There have been a few previous reports on FNA biopsy of orbital menigioma. We experienced a case of orbital meningioma in a 11-yr-old boy, diagnosed by FNA biopsy. The cytohistologic features of aspirated material (intranuclear inclusions, psammoma bodies, and cells arranged in whorls) made it easy to diagnose a meningloma.

  • PDF

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Significance of Fine-Needle Aspiration Cytology and Frozen Section Biopsy in Thyroid Nodules (갑상선 결절에서 세침흡인검사와 동결조직검사의 의의)

  • Song Dal-Won;Sohn Su-Gil;Choi Jong-Won;Shin Seung-Jin;Kim Tae-Jong;Nam Sung-Il;Ahn Byung-Hoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2003
  • Background and Objectives: Fine needle aspiration (FNA) cytology is a simple, safe and relatively accurate procedure of diagnosing thyroid nodules. Although the frozen section biopsy is well known as more reliable method than FNA and has high specificity, whether it is necessary it leaves room for adverse criticism. Authors have compared preoperative FNA cytology and frozen section biopsy with permanent histologic findings and evaluated the significance of FNA cytology and frozen section biopsy. Materials and Methods: The medical records of 110 patiens who underwent FNA cytology and frozen section during thyroidectomy from September. 1997 to December. 2001 at the Department of Otolaryngology, School of Medicine, Keimyung University were analyzed retrospectively. Results: Sensitivity, specificity, accuracy of FNA was 75%, 91.4%, and 85.5% respcetively. Sensitivity, specificity and accuracy rate of frozen section biopsy were 92.5%, 100% and 97.3% respectively. Conclusion: FNA is simple, with rare complication and its diagnostic accuracy is comparatively so high that it is being used as primary test to diagnosis thyroid nodules. But frozen section is more accurate and may be helpful to suspicious FNA findings or if it beyond capacity of FNA. Therefore despite of the fact that the intra-operative frozen is more expensive and time consuming, it is very helpful to the treatment of thyroid nodules by using jointly with FNA.

A Cytologic Study of Fine Needle Aspiration Biopsy of Salivary Gland Diseases (타액선 질환의 세침흡인생검에 관한 세포학적 연구)

  • Kim, Mi-Jin;Lee, Tae-Suk
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.2
    • /
    • pp.120-129
    • /
    • 1994
  • Fine needle aspiration biopsy cytology is a widely recognized and useful technique which can provide diagnosis in lesions of the head and neck, enabling appropriate management plans for individual patient to be made. Fifty one fine needle aspirates from salivary gland masses were examined. Four aspirates (8%) were inadequate for examination. Of the remaning 47 samples, 42 cases (82%) were benign lesions which consist of 30 pleomorphic adenoma(58%), 7 inflammatory lesion (14%), 4 Warthin's tumor(8%) and 1 benign lesion(2%). Two cases(4%) were atypical lesions. Three cases(6%) were malignant lesions consisting of 2 adenoid cystic carcinomas(4%) and 1 mucoepidermoid carcinoma (2%). The cytologic diagnoses were compared with the subsequent histologic diagnosis of surgical resected specimen in 24 cases. 19 cases of 21 aspirates from benign tumors were correctly diagnosed by fine needle aspiration cytology, with a specificity of 90%. All 3 aspirates from the 3 patients with malignant tumor were correctly diagnosed by fine needle aspiration cytology, with a sensitivity at 100%. Overall acurracy was 88%. Diagnostic error was encountered in adenoid cystic carcinoma, mucoepidermoid carcinoma and Warthin's tumor Correct histologic diagnosis was made in 86% of benign tumors(84% for pleomorphic adenoma and 100% for Warthin's tumor) and in 100% of malignant tumors.

  • PDF