Browse > Article
http://dx.doi.org/10.17946/JRST.2015.38.3.04

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy  

Lee, Mi-Hwa (Dept. of Health Care, Hanseo University, Dept. of Radiology, Kyung Hee University Hospital at GANGDONG)
Publication Information
Journal of radiological science and technology / v.38, no.3, 2015 , pp. 213-220 More about this Journal
Abstract
This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.
Keywords
Auto Exposure Control (AEC); Signal to Noise Ratio (SNR); Contrast Noise Ratio (CNR); Breast biopsy; Stereotactic biopsy; Phantom; Core needle biopsy; Sono guided biopsy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Gallagher WJ, Cardenosa G, Rubens JR, McCarthy KA, Kopans DB: Minimmal-Volume Excision of Nonpalpable Breast Lesions, AJR, 153, 957-961, 1989   DOI
2 Lee, H., M.,Lee, K., S., Lee, D., Y.: Preoperative Localization of Non-Palpable Breast Lesion, Korean Journal of Radiology, 30(2), 379-384, 1994   DOI
3 Gent HJ, Sprenger E, Dowlatshahi K: Stereotaxic needle localization and cytological diagnosis of occult breast lesions, Ann Surg, 204, 580-584, 1986   DOI
4 Hasselgren PO, Robert RP, Fieler MA: Breast biopsy with needle localization: Influence of age and mammographic feature on the rate of malignancy in 350 nonpalpable breast lesions, Surgery, 110, 623-628, 1991
5 Gisvold JJ, Martin JK: Prebiopsy localization of nonpalpable breast lesions, AJR, 143, 477-481, 1984   DOI
6 Huh, S., K., Yoon, J., H., Lee, K., H.: Usefulness of Stereotactic Localization of Nonpalpable Breast Lesions, Korean Journal of Radiology, 38(3), 553-558, 1998   DOI
7 Yang, J., H., Lee, H., K., Jung, S., H., Nam, S., J., Lee, B., B.,: Advanced Breast Biopsy Instrumentation: stereotactic Excisional Breast Biopsy for Nonpalpable Lesions, Journal of the korean surgical society, 56(3), 341-348, 1999
8 http://www.ihalla.com/read.php3?aid=1417705200483371288
9 H. M. Verkooijen: Diagnostic accuracy of stereotactic large-core needle biopsy for nonpalpable breast disease: Results of a multicenter prospective study with 95% surgical confirmation, Int. J. Cancer, 99, 853-859, 2002.   DOI
10 Bolmgren J, Jacobsen B, Nordenstrom B: Stereotactic instrument for needle biopsy of the mammo, Am J Roentgenol, 129, 121, 1997
11 Morrow M: When can stereotactic core biopsy replace excisional biopsy?-A clinical perspective, Br Cancer Res Tre, 36, 1, 1995   DOI
12 Schmidt RA: Srereotactic breast biopsy, Ca Cancer J Clin, 44(3), 172, 1994   DOI