• Title/Summary/Keyword: multiple mode method

Search Result 446, Processing Time 0.037 seconds

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

HPLC/MS/MS Method for Determination of Soyasaponins in the Soybean Varieties (콩 함유 사포닌의 종류 및 함량 분석)

  • Han, Sang-Jun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.3
    • /
    • pp.244-249
    • /
    • 2011
  • A sensitive and rapid high-performance liquid chromatographic-tandem mass spectrometric (HPLC/MS/MS) assay was developed for the determination of soyasaponins in soybean. Among soyasaponins, soyasaponin I was isolated and characterized from methanol extracts of soybean as analytical standards and the development of a new analytical procedure for quantification of its content in various cultivars. The structures of these compound was elucidated by $^1H$, $^{13}C$ NMR experiments and by mass spectrometric analysis. Aqueous ethanol extracts of soybean samples were injected on an Agilent XDB-C18 column ($4.6mm{\times}50mm$, $1.8{\mu}m$) with a mobile phase consisting of 10 mM ammonium acetate-acetonitrile, a flow rate of 0.3 mL/min and a total run time of 8 min. Detection was performed by mass spectrometer bin the multiple reaction monitoring (MRM) mode with negative electrospray ionization (ESI) m/z at 941 ${\rightarrow}$ 615 for soyasaponin I. In the 9 soybean samples, contents of soyasaponin I ranged from 205 to 726 mg/kg, and correlated negatively with seed size.

Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Battulga, Bulgan
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2018
  • Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.

Fabrication Technology of the Focusing Grating Coupler using Single-step Electron Beam Lithography

  • Kim, Tae-Youb;Kim, Yark-Yeon;Han, Gee-Pyeong;Paek, Mun-Cheol;Kim, Hae-Sung;Lim, Byeong-Ok;Kim, Sung-Chan;Shin, Dong-Hoon;Rhee, Jin-Koo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.30-37
    • /
    • 2002
  • A focusing grating coupler (FGC) was not fabricated by the 'Continuous Path Control'writing strategy but by an electron-beam lithography system of more general exposure mode, which matches not only the address grid with the grating period but also an integer multiple of the address grid resolution (5 nm). To more simplify the fabrication, we are able to reduce a process step without large decrease of pattern quality by excluding a conducting material or layer such as metal (Al, Cr, Au), which are deposited on top or bottom of an e-beam resist to prevent charge build-up during e-beam exposure. A grating pitch period and an aperture feature size of the FGC designed and fabricated by e-beam lithography and reactive ion etching were ranged over 384.3 nm to 448.2 nm, and 0.5 $\times$ 0.5 mm$^2$area, respectively. This fabrication method presented will reduce processing time and improve the grating quality by means of a consideration of the address grid resolution, grating direction, pitch size and shapes when exposing. Here our investigations concentrate on the design and efficient fabrication results of the FGC for coupling from slab waveguide to a spot in free space.

An Efficient Data Dissemination Protocol for Cluster-based Wireless Sensor Networks (클러스터 기반의 무선 센서네트워크에서 통신량을 줄인 데이터 보급방법)

  • Cho, Ji-Eun;Choe, Jong-Won
    • Journal of KIISE:Information Networking
    • /
    • v.36 no.3
    • /
    • pp.222-230
    • /
    • 2009
  • A sensor network is an important element of the ubiquitous and it consists of sensor fields that contain sensor nodes and sink nodes that collect data from sensor nodes. Since each sensor node has limited resources, one of the important issues covered in the past sensor network studies has been maximizing the usage of limited energy to extend network lifetime. However, most studies have only considered fixed sink nodes, which created various problems for cases with multiple mobile sink nodes. Accordingly, while maintaining routes to mobile sink nodes, this study aims to deploy the hybrid communication mode that combines single and multi-hop modes for intra-cluster and inter-cluster transmission to resolve the problem of failed data transmission to mobile sink nodes caused by disconnected routes. Furthermore, a 2-level hierarchical routing protocol was used to reduce the number of sensor nodes participating in data transmission, and cross-shape trajectory forwarding was employed in packet transmission to provide an efficient data dissemination method.

Bitcoin and the Monetary System Revolution Changes

  • Alotaibi, Leena;Alsalmi, Azhar;Alsuwat, Hatim;Alsuwat, Emad
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.156-160
    • /
    • 2021
  • Every day brings a new challenge to the humanities. Life nowadays needs accuracy, privacy, integrity, authenticity, and security to run life systems especially the monetary system. Things now differ from previous centuries. Multiple varieties in digital banking have opened the new and most advanced innovations for human beings. The monetary system is going to developed day by day to facilitate the public. Electronic money has amazed the world and gave a challenge to central banking. For this purpose, there will be a need for strict security, information, and confidence. Blockchain technology has opened new gateways. Bitcoin has become the most famous digital currency, which has created a thunderstorm in digital marketing. Blockchain, as a new Financial Technology, has satisfied all the security issues and satisfied doing business in secure ways that encourage investors to invest and keep the world business wheel. Assessment of the sustainability of implementing Bitcoin in financial institutions will be discussed. Every new system has its pros and cons in which a clear vision of what we are about to use can be sought. Through this research paper, a demonstration of the monetary system evolution, the new ways of doing business, some evidence in a form of academic cases will be demonstrated through comparison a table, a suggested method to transfer to the new system in safe mode will be proposed, and a conclusion will be concluded.

Evaluation of storage period of fresh ginseng for quality improvement of dried and red processed varieties

  • Zhang, Na;Huang, Xin;Guo, Yun-Long;Yue, Hao;Chen, Chang-Bao;Liu, Shu-Ying
    • Journal of Ginseng Research
    • /
    • v.46 no.2
    • /
    • pp.290-295
    • /
    • 2022
  • Background: Dried and red ginseng are well-known types of processed ginseng and are widely used as healthy food. The dried and red ginseng quality may vary with the storage period of raw ginseng. Therefore, herein, the effect of the storage period of fresh ginseng on processed ginseng quality was evaluated through multicomponent quantification with statistical analysis. Methods: A method based on ultrahigh performance liquid chromatography coupled to triple quadrupole mass spectrometry in multiple-reaction monitoring mode (UPLC-MRM-MS) was developed for quantitation of ginsenosides and oligosaccharides in dried and red ginseng. Principal component analysis and partial least squares discriminant analysis were conducted to evaluate the dynamic distributions of ginsenosides and oligosaccharides after different storage periods. Results: Eighteen PPD, PPT and OLE ginsenosides and nine reducing and nonreducing oligosaccharides were identified and quantified. With storage period extension, the ginsenoside content in the processed ginseng increased slightly in the first 2 weeks and decreased gradually in the following 9 weeks. The content of reducing oligosaccharides decreased continuously as storage time extending, while that of the nonreducing oligosaccharides increased. Chemical conversions occurred during storage, based on which potential chemical markers for the storage period evaluation of fresh ginseng were screened. Conclusion: According to ginsenoside and oligosaccharide distributions, it was found that the optimal storage period was 2 weeks and that the storage period of fresh ginseng should not exceed 4 weeks at 0 ℃. This study provides deep insights into the quality control of processed ginseng and comprehensive factors for storage of raw ginseng.

Numerical Model for Cerebrovascular Hemodynamics with Indocyanine Green Fluorescence Videoangiography

  • Hwayeong Cheon;Young-Je Son;Sung Bae Park;Pyoung-Seop Shim;Joo-Hiuk Son;Hee-Jin Yang
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.382-392
    • /
    • 2023
  • Objective : The use of indocyanine green videoangiography (ICG-VA) to assess blood flow in the brain during cerebrovascular surgery has been increasing. Clinical studies on ICG-VA have predominantly focused on qualitative analysis. However, quantitative analysis numerical modelling for time profiling enables a more accurate evaluation of blood flow kinetics. In this study, we established a multiple exponential modified Gaussian (multi-EMG) model for quantitative ICG-VA to understand accurately the status of cerebral hemodynamics. Methods : We obtained clinical data of cerebral blood flow acquired the quantitative analysis ICG-VA during cerebrovascular surgery. Varied asymmetric peak functions were compared to find the most matching function form with clinical data by using a nonlinear regression algorithm. To verify the result of the nonlinear regression, the mode function was applied to various types of data. Results : The proposed multi-EMG model is well fitted to the clinical data. Because the primary parameters-growth and decay rates, and peak center and heights-of the model are characteristics of model function, they provide accurate reference values for assessing cerebral hemodynamics in various conditions. In addition, the primary parameters can be estimated on the curves with partially missed data. The accuracy of the model estimation was verified by a repeated curve fitting method using manipulation of missing data. Conclusion : The multi-EMG model can possibly serve as a universal model for cerebral hemodynamics in a comparison with other asymmetric peak functions. According to the results, the model can be helpful for clinical research assessment of cerebrovascular hemodynamics in a clinical setting.

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.

Development of LC-MS/MS Quantitation Method for Ethoxyquin in Fishery Products (수산물 중 에톡시퀸의 LC-MS/MS 정량분석법 개발)

  • Shin, Dasom;Chae, Young-Sik;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.432-438
    • /
    • 2016
  • Ethoxyquin (EQ, 1,2-dihydro-6-ethoxy-2,2,4-trimethyl-quinoline) is quinoline-based antioxidant used in the animal feed and food industry to protect the raw materials and final products against oxidation. In recent years the use of synthetic antioxidants in fishmeal ingredients carry-over to farmed fish fillets has received increasing attention in food safety. This study was conducted to develop an analytical method to determine EQ in aquatic products. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with 1 N HCl (in case of flatfish extracted with 1 N HCl containing 10% acetonitrile). Then, solid phase extraction (SPE) was used for the cleanup. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.99, analyzed at 0.005-0.2 mg/kg concentration. The developed method was validated according to the Codex Alimentarius Commission (CAC) guideline. The limits of quantitation for EQ were 0.01 mg/kg. Average recoveries ranged from 81.3% to 107%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was below 10%. The analytical method was characterized with high accuracy and acceptable sensitivity to meet CODEX guideline requirements and would be applicable to analyze the EQ residue in aquatic products.