• 제목/요약/키워드: microfluidics

검색결과 165건 처리시간 0.027초

Bio-MEMS분야의 최근 연구동향 (Recent research trends on Bio-MEMS)

  • 박세광;양주란
    • 센서학회지
    • /
    • 제19권4호
    • /
    • pp.259-270
    • /
    • 2010
  • MEMS(micro electro mechanical systems) is a technology for the manufacture hyperfine structure, as a micro-sensor and a driving device, by a variety of materials such as silicon and polymer. Many study for utilizing the MEMS applications have been performed in variety of fields, such as light devices, high frequency equipments, bio-technology, energy applications and other applications. Especially, the field of Bio-MEMS related with bio-technology is very attractive, because it have the potential technology for the miniaturization of the medical diagnosis system. Bio-MEMS, the compound word formed from the words 'Bio-technology' and 'MEMS', is hyperfine devices to analyze biological signals in vitro or in vivo. It is extending the range of its application area, by combination with nano-technology(NT), Information Technology(IT). The LOC(lab-on-a-chip) in Bio-MEMS, the comprehensive measurement system combined with Micro fluidic systems, bio-sensors and bio-materials, is the representative technology for the miniaturization of the medical diagnosis system. Therefore, many researchers around the world are performing research on this area. In this paper, the application, development and market trends of Bio-MEMS are investigated.

OLED광원이 집적화된 마이크로 플루이딕칩의 제작 및 특성 평가 (Fabrication and characteristic evaluation of microfluidics chip integrated OLED for the light sources)

  • 김영환;한진우;김종연;김병용;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.377-377
    • /
    • 2007
  • A simplified integration process including packaging is presented, which enables the realization of the portable fluorescence detection system. A fluorescence detection microchip system consisting of an integrated PIN photodiode, an organic light emitting diode (OLED) as the light source, an interference filter, and a microchannel was developed. The on-chip fluorescence detector fabricated by poly(dimethylsiloxane) (PDMS)-based packaging had thin-film structure. A silicon-based integrated PIN photo diode combined with an optical filter removed the background noise, which was produced by an excitation source, on the same substrate. The active area of the finger-type PIN photo diode was extended to obtain a higher detection sensitivity of fluorescence. The sensitivity and the limit of detection (LOD S/N = 3) of the system were $0.198\;nA/{\mu}M$ and $10\;{\mu}M$, respectively.

  • PDF

마이크로 채널 충전 과정의 유동 현상(I) - 유동 가시화 실험 - (Flow Phenomena in Micro-Channel Filling Process (I) - Flow Visualization Experiment -)

  • 김동성;이광철;권태헌;이승섭
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.1982-1988
    • /
    • 2002
  • Micro-injection molding and microfluidic devices with the help of MEMS technologies including the LIGA process are expected to play important roles in micro-system industries, in particular the bio-application industry, in the near future. Understanding fluid flows in micro-channels is important since micro-channels are typical geometry in various microfluidic devices and mold inserts for micro-injection molding. In the present study, Part 1, an experimental investigation has been carried out to understand the detailed flow phenomena in micro-channel filling process. Three sets of micro-channels of different thickness (40um,30um and 2011m) were fabricated using SU-8 on silicon wafer substrate. And a flow visualization system was developed to observe the filling flow into the micro-channels. Experimental flow observations are extensively made to find the effects of pressure, inertia force, viscous force and surface tension. A dimensional analysis for experimental results was carried out and several relationships A dimensionless parameters are obtained.

순환종양세포 검출 기술 (Current Methods of Circulating Tumor Cell Detection)

  • 임민지;조윤경
    • 대한상부위장관⦁헬리코박터학회지
    • /
    • 제18권3호
    • /
    • pp.157-161
    • /
    • 2018
  • Liquid biopsy, the analysis of circulating biomarkers from peripheral blood, such as circulating tumor cells (CTCs) and circulating tumor DNA, and exosomes, offers a less invasive, new source of cancer-derived materials that may reflect the status of the disease better and thereby contribute to personalized treatment. Recent advances in microfluidics and molecular analysis technologies have resulted in greatly improved CTC enumeration and detection. In this article, we review commercially available technologies used to isolate CTCs from peripheral blood, including immunoaffinity and label-free, physical property-based isolation methods. Although enormous technological progress has been made, especially within the last decade, only a few CTC detection methods have been approved for routine clinical use. Here, we provide an overview of the current CTC isolation methods and examples of their potential application for early diagnosis, prognosis, treatment monitoring, and prediction of resistance to cancer therapy. Furthermore, the challenges that remain to be addressed before such tools are implemented for routine use in clinical settings are discussed.

Effects of Ionic Strength in the Medium on Sample Preconcentration Utilizing Nano-interstices between Self-Assembled Monolayers of Gold Nanoparticles

  • Nguyen, Ngoc-Viet;Wu, Jian-Sheng;Jen, Chun-Ping
    • BioChip Journal
    • /
    • 제12권4호
    • /
    • pp.317-325
    • /
    • 2018
  • This paper investigated the effects of ionic strength in the medium on a preconcentrator for a protein sample with low concentration. The preconcentration chip was designed and fabricated using a polydimethylsiloxane replica through standard lithophotography. A glass substrate is silanized prior to functionalizing the nanoparticles for self-assembly at a designed region. Due to the overlap of electrical double layers in a nanofluidic channel, a concentration polarization effect can be achieved using an electric field. A nonlinear electrokinetic flow is induced, resulting in the fast accumulation of proteins in front of the induced ionic depletion zone, so called exclusion-enrichment effect. Thus, the protein sample can be driven by electroosmotic flow and accumulated at a specific location. The chip is used to collect fluorescein isothiocyanate-labeled bovine serum albumin (FITC-BSA) diluted in phosphate-buffered saline (PBS) buffer solution. Different concentrations of the buffer media were studied herein. Fluorescence intensity images show that the buffer concentration of 4 mM is more appropriate than all the other ones. The sample of FITC-BSA with an initial concentration of $10{\mu}M$ in the 4 mM PBS solution increases its concentration at the desired region by up to 50 times within 30 min, demonstrating the results in this investigation.

표면파 유도 음향방사력을 이용한 미세액적의 크기 선별 (Size-based separation of microscale droplets by surface acoustic wave-induced acoustic radiation force)

  • 무스타크 알리;차범석;무하마드 소반 칸;전현우;이송하;김우혁;고정우;박진수
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.19-26
    • /
    • 2022
  • In droplet microfluidics, precise droplet manipulation is required in numerous applications. This study presents ultrasonic surface acoustic wave (USAW)-based microfluidic device for label-free droplet separation based on size. The proposed device is composed of a slanted-finger interdigital transducer on a piezoelectric substrate and a polydimethylsiloxane microchannel placed on the substrate. The microchannel is aligned in the cross-type configuration where the USAWs propagate in a perpendicular direction to the flow in the microchannel. When droplets are exposed to an acoustic field, they experience the USAW-induced acoustic radiation force (ARF), whose magnitude varies depending on the droplet size. We modeled the USAW-induced ARF based on ray acoustics and conducted a series of experiments to separate different-sized droplets. We found that the experimental results were in good agreement with the theoretical estimation. We believe that the proposed method will serve as a promising tool for size-based droplet separation in a label-free manner.

Slipchip Device Development in Molecular Diagnostics

  • Qingtian Yin;Huiwen Bai;Ruijie Li;Youngung Seok
    • 한국재료학회지
    • /
    • 제34권2호
    • /
    • pp.63-71
    • /
    • 2024
  • Slipchip offers advantages such as high-throughout, low cost, and simple operation, and therefore, it is one of the technologies with the greatest potential for high-throughput, single-cell, and single-molecule analyses. Slipchip devices have achieved remarkable advances over the past decades, with its simplified molecular diagnostics gaining particular attention, especially during the COVID-19 pandemic and in various infectious diseases scenarios. Medical testing based on nucleic acid amplification in the Slipchip has become a promising alternative simple and rapid diagnostic tool in field situations. Herein, we present a comprehensive review of Slipchip device advances in molecular diagnostics, highlighting its use in digital recombinase polymerase amplification (RPA), loop-mediated isothermal amplification (LAMP), and polymerase chain reaction (PCR). Slipchip technology allows users to conduct reliable droplet transfers with high-throughput potential for single-cell and molecule analyses. This review explores the device's versatility in miniaturized and rapid molecular diagnostics. A complete Slipchip device can be operated without special equipment or skilled handling, and provides high-throughput results in minimum settings. This review focuses on recent developments and Slipchip device challenges that need to be addressed for further advancements in microfluidics technology.

미세채널에서 수력학적 조절을 통한 단분산성 다중 액적 생성 (Microfluidic Preparation of Monodisperse Multiple Emulsion using Hydrodynamic Control)

  • 강성민;최창형;황소라;정재민;이창수
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.733-737
    • /
    • 2012
  • 본 연구는 미세유체의 수력학적 조절을 통한 단분산성 다중 액적 형성방법을 기술한다. 다중 액적을 형성하기 위해 별도의 표면 개질이 필요 없는 co-flowing stream 시스템과 유리 모세관을 이용하여 미세유체 칩을 제작하였다. 유리모세관 미세유체 칩 내부로 0.5 wt% Tween 20이 함유된 증류수, n-hexadecane (5 wt% Span 80), 그리고 10 wt% poly(vinyl alcohol) (PVA) 수용액을 흘려줌으로써 단분산성 다중 액적(W/O/W)을 성공적으로 형성하였다. 더불어, 내부 액적의 개수를 제어하기 위해 수력학적 변수로 작용하는 중간 유체와 최외각 유체의 부피유속을 고정시키고 내부 유체의 부피유속을 조절하는 방법을 사용하여 다양한 내부 액적을 지니는 다중 유화 액적을 성공적으로 완성하였다. 이와 같은 미세유체 시스템을 통해 형성된 다중 액적은 내부물질의 종류에 따라 다양한 화학반응을 위한 하나의 독립된 마이크로 반응기로 사용될 수 있을 것으로 기대한다.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권4호
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

종이-미세유체공학을 이용한 건성안 검사 용지 개발 (Development of Paper-based Microfluidic Device for Dry Eye Test)

  • 서영태;노혜란
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.93-99
    • /
    • 2013
  • 목적: 본 연구는 현장현시 건성안 진단 테스트 중에 현재 사용되고 있으나 부정확한 결과로 신뢰도가 떨어지는 쉬르머 용지를 대체 할 수 있는 차세대 건성안 진단 테스트 용지를 미세유체공학을 이용하여 개발하고자 하였다. 방법: 왁스로 패턴을 제조한 친수성 크로마토그래피 용지를 pH에 따른 색 변화가 나타나도록 안토시안으로 염색을 하였다. 인공 누액의 젖음 속도를 인공 누액과 32명의 참가자의 눈물을 이용하여 임상 측정하였다. 결과: 인공 누액을 이용하였을 경우 쉬르머 용지에서는 소량의 용액은(0.5 ml이하) 흡수거리가 도출되지 않았으나 새로 개발된 용지는 시간에 따른 인공 누액의 흡수거리가 확연히 나타났다. 임상실험에서도 새로 개발된 검사 용지는 TBUT (tear break-up time)결과와 부합하는 건성안 진단 결과를 보였다. 결론: 개발된 건성안 진단 용지는 간편하게 사용될 수 있을 뿐만 아니라 기존 쉬르머 용지와 같은 현장현시 건성안 진단 매체와 비교 했을 경우 건성안 판별의 정확성이 높았다.