• Title/Summary/Keyword: micro-hole

Search Result 328, Processing Time 0.025 seconds

Dependence of the Transmission Characteristics of Photonic Crystal Fiber on the Macrobending Radius and the Mechanically Induced Microbending

  • Lee, Byeong-Ha;Moon, Dae-Seung;Eom, Joo-Beom;Kim, Jin-Chae;Kim, Hok-Young;Paek, Un-Chul
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.72-78
    • /
    • 2003
  • It is reported that the spectral loss of photonic crystal fiber (PCF) having a large hole-to-hole distance (~ 10 ${\mu}{\textrm}{m}$) is sensitive to micro- and macrobending when compared with the conventional single-mode fiber. In this paper, we will present the measurement result of the macro- and microbending characteristics of fabricated PCF with large hole-to-hole distance (> 10 ${\mu}{\textrm}{m}$) . For the macrobending experiment, the fiber was simply wound around a circular structure with variable diameter that could be reduced to a few centimeters. For the microbending case, regularly spaced silica rods were attached on a slide glass and pressed against the fiber by loading a stack of metal plates of known weight on the glass. The transmission loss spectrum shows a rather flat response to the to microbending, and this makes the PCF a good candidate for a wideband variable optical attenuator.

A Study on Improvement of Image Processing for Precision Inner Diameter Measurement of Circular Hole (원형구멍 정밀 내경측정을 위한 영상처리 개선에 관한 연구)

  • Park, ChangYong;Kweon, HyunKyu;Li, JingHua;Zhang, Hua Xin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.8-13
    • /
    • 2017
  • In this paper, the measurement of the inner diameter dimension of the circular hole by using a machine vision system was studied. This paper was focused on the theory and key technologies of machine vision inspection technology for the improvement of measurement accuracy and speed of the micro circular holes. A new method was proposed and was verified through the experiments on Gray conversion, binarization, edge extraction and Hough transform in machine vision system processes. Firstly, the Hough transform was proposed in order to improve the speed increase and implementation ease, it demonstrated the superiority of Hough transform and improvement through a comparative experiment. Secondly, we propose a calibration method of the system in order to obtain exactly the inner diameter of the circular hole. Finally, we demonstrate the reliability of the entire system as a MATLAB-based implementation of the GUI program, measuring the inner diameter of the circular hole through the circular holes of different dimensions measuring experiment.

  • PDF

Fabrication of the Micro-pump using Stereolithography Technology (Stereolithography 기술을 이용한 마이크로 펌프 제작)

  • Lee, Young-Tae;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.232-238
    • /
    • 2001
  • We fabricated micro-pump using stereolithography technology. The pump was fabricated using PZT for its drive and used non-movable valve of diffuser/nozzle concept. Size of the pump chamber is, $14mm{\psi}$, narrow hole of diffuser/nozzle is $0.5mm{\psi}$ and wide hole $1mm{\psi}$ and chamber depth is 1.2mm, respectively. We confirmed its operation at frequency 100Hz, supply voltage $90{\sim}250Vp-p$. As the result of the pump working measurement, when ethanol is used, the pressure head difference between inlet and outlet of the pump is about 53mm in the frequency of 100Hz, 200V of Vp-p.

  • PDF

Microfluidic Control for Biological Cell Orientation

  • Namkung, Young-Woo;Park, Jung-Yul;Kim, Byung-Kyu;Park, Jong-Oh;Kim, Jin-Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2457-2460
    • /
    • 2003
  • There is a great demand to manipulate biological cell autonomously since biologist should spend much time to obtain skillful manipulation techniques. For this purpose, we propose a cell chip to control, carry, fix and locate the cell. In this paper, we focus on the cell rotator to rotate individual biological cell based on a micro fluidics technology. The cell rotator consists of injection hole and rotation well to rotate a biological cell properly. Under the variation of flow rate in injection hole, the angular velocity of a biological cell is evaluated to find the feasibility of the proposed rotation method. As a practical experiment, Zebrafish egg is employed. Based on this research, we find the possibility of non-contact rotation way that can highly reduce the damage of the biological cell during manipulation. To realize an autonomous biological cell manipulation, a cell chip with manipulation well and micro channel in this research will be utilized effectively in near future.

  • PDF

Laser Drilling System for Fabrication of Micro via Hole of PCB (인쇄회로기판의 미세 신호 연결 홀 형성을 위한 레이저 드릴링 시스템)

  • Cho, Kwang-Woo;Park, Hong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.14-22
    • /
    • 2010
  • The most costly and time-consuming process in the fabrication of today's multi-layer circuit board is drilling interconnection holes between adjacent layers and via holes within a layer. Decreasing size of via holes being demanded and growing number of via holes per panel increase drilling costs. Component density and electronic functionality of today's multi-layer circuit boards can be improved with the introduction of cost-effective, variable depth laser drilled blind micro via holes, and interconnection holes. Laser technology is being quickly adopted into the circuit board industry but can be accelerated with the introduction of a true production laser drilling system. In order to get optimized condition for drilling to FPCB (Flexible Printed Circuit Board), we use various drill pattern as drill step. For productivity, we investigate drill path optimization method. And for the precise drilling the thermal drift of scanner and temperature change of scan system are tested.

Design of High frequency Vibration Mechanism with PZT actuator for Ultraprecision Laser Machining (압전구동기를 이용한 초정밀레이저 가공의 고주파진동 장치설계)

  • Kim, Hyun-Uk;Hwang, Dong-Hyun;Park, Jong-Kweon;Cho, Sung-Hak;Lee, Moon-G.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.3
    • /
    • pp.419-425
    • /
    • 2010
  • To machine the micro hole, laser machining system is widely used, however, the system cannot fabricate the micro hole with high aspect ratio and good surface finish. To break the obstacles, the high frequency vibration mechanism with PZT (Piezoelectric Transducers) is proposed in this paper. The mechanism will vibrate the laser beam in vertical direction so that the aspect ratio and surface finish may be higher than the conventional. The mechanism vibrates the eyepiece of laser optics. In addition to the benefits, the mechanism enables us to have high precision and flexibility. It decreases burr and debris during machining. And it is able to machine various materials of workpiece. This research include high frequency and large travel range of the proposed mechanism. The PZT motion of mechanism and analysis on the sensitivity of design parameters are extracted from a finite element method (FEM) simulation. In the analysis, the target vibration mode without parasitic motion is designated to have the target frequency and high amplitude.

The Experiment on the effect of variations of voltage frequency and duty r on the electrochemical discharge machining of Pyrex glass (전압 주파수와 파형 폭 변화에 따른 유리의 미세 전해 방전 가공 성능에 대한 실험)

  • Lee, Jung-Yong;Ahn, Yoo-Min;Ahn, Si-Hong;Park, Chi-Hyun;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3307-3309
    • /
    • 1999
  • Electrochemical discharge machining (ECDM) is a very recent technique in the fabrication of the micro-electro-mechanical system ( MEMS ) devices. This paper presents the experimental results of the machining of micro-holes on pyrex glass substrates by use of ECDM. Electrolyte is used with a KOH aqueous solution, cathode with copper, anode with platinum, and tool feed system is applied with gravity feed system. Already established experimental results were taken under the condition of constant voltage frequency. However in this paper, the effect of variation of the voltage frequency and duty ratio is considered. In this experiment, it is measured the ECDM performances with variation of the voltage frequency and duty ratio under the conditions of constant other machining variables. ECDM performances are described by the hole depth, and the top hole diameter.

  • PDF

Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation- (혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 -)

  • Chang, Jun-Keun;Chung, Seok;Lee, Yong-Ku
    • Tribology and Lubricants
    • /
    • v.15 no.3
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

Forging Simulation of a Micro-Former Forging Process of an ABS Part (ABS 용 부품의 마이크로 포머단조공정 시뮬레이션)

  • Choi, I.S.;Yoo, S.W.;Park, S.G.;Yoon, D.J.;Joun, M.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.165-169
    • /
    • 2007
  • In this study, the factors that have strong relationship with size effects on forging simulation are investigated and then a dimensionless concept is implemented into the forging simulator. The approach is applied to simulating a micro former forging process of which sequence involves a piercing process to make a hole of 0.7mm diameter of the product whose maximum diameter is 3mm. The simulated results are discussed to reveal the size effect in forging simulation.

  • PDF

A Study on the Micro Hole Drilling Characteristics of Machinable Ceramics (머시너블 세라믹스의 마이크로 홀 가공특성에 관한 연구)

  • 김동우;조명우;조원승;이응숙
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.597-602
    • /
    • 2002
  • Ceramics are very difficult-to-cut materials because of its high strength and hardness. Their machining mechanism is characterized by cracking and brittle fracture. In this paper, to give good machinability to the ceramics, BN powders are added to Si$_3$N$_4$ by volume of 20, 25 and 30%. And the machiniability of the produced ceramics are tested using micro drilling system. Through required experimental works, it is shown that the micro drilling machinability is varied along with the volumetric percentage of BN powders. Also, it is verified that the obtained results can be used to develop new machinable ceramics of good material properties and machinability.

  • PDF