• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.03 seconds

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Low-dose radiation therapy for massive chylous leakage after subtotal gastrectomy

  • Kim, Sang-Won;Kim, Jung Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.380-384
    • /
    • 2017
  • Massive chylous leakage is a rare postoperative complication that can prolong hospital stay and cause secondary morbidities. Conservative management strategies are the treatment of choice; however, radiation therapy (RT) can be used as an alternative for cases that are refractory to conservative treatment. Herein, we report a 69-year-old female patient who suffered from massive chylous leakage after subtotal gastrectomy. Due to persistent massive chylous leakage, she was scheduled to undergo low-dose RT. Radiation was delivered with a daily dose of 1 Gy, using an anterior-posterior and posterior-anterior beam arrangement. The clinical target volume encompassed the entire lymph node area of the D2 dissection. RT was completed at the total dose of 8 Gy because the amount of chylous leakage declined rapidly. Percutaneous drainage tube was removed after 3 days of RT. The patient did not complain of any symptoms related to massive chylous leakage 2 years after the completion of RT.

Leakage Characteristics of LPG injector with Low Viscosity LPG Fuel (저점도 LPG연료 인젝터의 누설특성에 관한 연구)

  • Kim, C.U.;Park, C.W.;Oh, S.M.;Kang, K.Y.
    • Journal of ILASS-Korea
    • /
    • v.10 no.4
    • /
    • pp.8-15
    • /
    • 2005
  • The use of clean gaseous fuels for the purpose of high efficiency and low emission in automotive engines has tendency to increase in order to meet the reinforcing emission regulations and to efficiently utilize limited natural resources. Automotive companies developed and commercialized a LPG liquid injection system, which is mounted on LPLi(Liquid Phase LPG Injection) engines and vehicles based on this research trend. This research examines the biggest problem in LPLi engine, that is, the leakage characteristics of low viscosity LPG fuel according to the injector design variables. This study is also aimed to improve the performance of fuel-leakage in LPLi engine through the addition of a lubrication improver in HFRR(High Frequency Reciprocating Rig) facility. The needle displacement and the spring displacement of an LPLi injector are found to be already optimized. The possibility of a maximum of 70% leakage reduction compared to a conventional case, is verified when 1000ppm of a lubrication improvement material is added and 40% increase of a injector spring constant (K) is applied.

  • PDF

Printing of Polymer Dielectric via Optimal Blade Coating for Large-scale Low-Leakage Capacitors (대면적 저누설 커패시터를 위한 최적화 블레이드 코팅 기반 고분자 유전체 프린팅)

  • Seo, Kyeong-Ho;Bae, Jin-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.51-55
    • /
    • 2021
  • We demonstrated a polymer dielectric with low leakage characteristics through an optimal blade coating method for low-cost and large-scale fabrication of metal-insulator-metal (MIM) capacitors. Cross-linked poly(4-vinylphenol) (C-PVP), which is a typically used polymer dielectric, was coated on a 10 × 10 cm indium-tin-oxide (ITO) deposited glass substrate by changing the deposition temperature (TD) and coating velocity (VC) in the blade coating. During the blade coating, the thickness of the thin c-PVP varied depending on TD and VC owing to the 'Landau-Levich (LL) regime'. The c-PVP-dielectric-based MIM capacitor fabricated in this study showed the lowest leakage current characteristics (10-6 A/㎠ at 1.2 MV/㎠, annealing at 200 ℃) and uniform electrical characteristics when TD was 30 ℃ and VC was 5 mm/s. In addition, at TD = 30 ℃, stable leakage characteristics were confirmed when a different electric field was applied. These results are expected to positively contribute to applications with next-generation electronic devices.

An Experimental Study on the Leakage Characteristics of a Labyrinth Seal (Labyrinth Seal 의 누설 특성 실험)

  • 하현천;변형현;박철현
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.141-146
    • /
    • 1999
  • An experimental investigation on the leakage characteristics of a labyrinth seal, high-low seal, is studied. Pressure distribution and leakage flow rate are measured along with the shaft speed and the pressure difference between the entrance and the exit. Pressure distribution vanes almost linearly along the seal and the leakage flow rate increases as the increase of the pressure difference. Furthermore, it is found that both the shaft speed and the shaft vibration have no influence on the leakage of the labyrinth seal.

  • PDF

Low Leakage Input Vector Searching Techniques for Logic Circuits at Standby States (대기상태인 논리 회로에서의 누설전류 최소화 입력 탐색 방법)

  • Lee, Sung-Chul;Shin, Hyun-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.53-60
    • /
    • 2009
  • Due to increased integration density and reduced threshold voltages, leakage current reduction becomes important in the semiconductor IC design for low power consumption. In a combinational logic circuit, the leakage current in the standby state depends on the values of the input. In this research, we developed a new input vector control method to minimize the leakage power. A new efficient algorithm is developed to find the minimal leakage vector. It can reduce the leakage current by 15.7% from the average leakage current and by 6.7% from the results of simulated evolution method during standby or idle states for a set of benchmark circuits. The minimal leakage input vector, with idle input signal, can also reduce the leakage current by 6.8% from the average leakage current and by 3.2% from the results of simulated evolution method for sequential circuits.

A New Method for Resistive Leakage Current Measurement (새로운 저항성 누전전류 측정 방법)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

Dynamic Boric Acid Corrosion of Low Alloy Steel for Reactor Pressure Vessel of PWR using Mockup Test (가압형 경수로 압력용기 재료인 저합금강의 동적 붕산 부식 실증 연구)

  • Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • This work is concerned with an evaluation of dynamic boric acid corrosion (BAC) of low alloy steel for reactor pressure vessel of a pressurized water reactor (PWR). Mockup test method was newly established to investigate dynamic BAC of the low alloy steel under various conditions simulating a primary water leakage incident. The average corrosion rate was measured from the weight loss of the low alloy steel specimen, and the maximum corrosion rate was obtained by the surface profilometry after the mockup test. The corrosion rates increased with the rise of the leakage rate of the primary water containing boric acid, and the presence of oxygen dissolved in the primary water also accelerated the corrosion. From the specimen surface analysis, it was found that typical flow-accelerated corrosion and jet-impingement occurred under two-phase fluid of water droplet and steam environment. The maximum corrosion rate was determined as 5.97 mm/year at the leakage rate of 20 cc/min of the primary water with a saturated content of oxygen within the range of experimental condition of this work.

A Characteristic analysis of EHV insulators on long-term outdoor tests (송전용 애자의 장기실증시험 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.392-396
    • /
    • 2004
  • Experimental equipments for long-term outdoor tests of EHV insulators in outdoor were constructed. The testing insulators have been energized with 89 [kV] phase-to-ground AC voltage under identical condition at station, and the investigation was carried out for leakage current and various environments such as temperature, relative humidity and wind velocity. The test results of leakage current wave trends have forms on distorted waves including harmonics. The porcelain and glass insulators have low leakage current in case of daytime because moisture and humidity have relative low values. In comparison with these conditions, high leakage current was shown at dawn and rainy day due to high humidity. However, leakage current of polymer insulators was shown approximately $129[{\mu}m]$ without relation to the weather due to hydrophobicity on their surface.

  • PDF

A New method for the Calculation of Leakage Reactance in Power Transformers

  • Dawood, Kamran;Alboyaci, Bora;Cinar, Mehmet Aytac;Sonmez, Olus
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1883-1890
    • /
    • 2017
  • Transformers are one of the most precious elements of the electric power system. Stability and reliability of the electric power network mainly depend on the working of the transformer. Leakage reactance of the transformer is one of the important factors and accurate calculation of the leakage reactance is necessary for the transformer designers and electric distributors. Leakage reactance of the transformer depends on the geometry of the transformer. There are many different methods for the calculations of the leakage reactance however mostly are usable when the axial heights of the high voltage and low voltage windings are equal. When the axial heights of high voltage and low voltage windings are asymmetric most of the analytical methods are not reliable. In this study, a new analytical method is introduced for the calculation of the leakage reactance. Fourteen different transformers are investigated in this study and four of them are presented in this paper. The results of the new analytical method are compared with the experimental results. Other analytical and numerical methods are also compared with this new method. Results show that this method is more reliable and accurate as compared to the other analytical methods. The maximum relative error between short-circuit test and proposed method for these fourteen transformers was less than 2.8%.