• 제목/요약/키워드: low frequency inverter

검색결과 397건 처리시간 0.031초

분말 자성 코어의 형상에 따른 인버터용 인덕터의 소음특성 (Acoustic Noise Characteristics of Inductor According to Magnetic Powder Core Building Structure for Inverter Application)

  • 유광용;이병국;김동희
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1591-1599
    • /
    • 2017
  • In power electronics applications which switching frequency is below audible frequency, the acoustic noise and vibration design of magnetics are as important as the efficiency. In the case of the powder core, which is widely used in grid-connected inverters, many researches have been progressed in terms of efficiency. However, there are only few research have been progressed related with acoustic noise and vibrations. In this paper, the Sendust(Fe-Si-Al) powder core material which has low magnetostriction and low core loss is analyzed in terms of acoustic noise and vibration induced by Maxwell force and magnetostriction. Three building structures such as, rectangular, toroidal, and oval shape are designed for 4kW grid-connected inverter, because magnetic properties and the audible noises of the inductor are varied by magnetic core building structures. The effects of the Maxwell force and magnetostriction behaviors varied with core shapes are analyzed by finite element method and experiments. In addition, experiment results of the inductor efficiency are presented according to core building structures.

무정전 전원(UPS)설계를 위한 PWN 인버터에 관한 연구 (A Study on the PWN Inverter for the Design of UPS)

  • 이성백;구용회;이종규
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제2권2호
    • /
    • pp.59-63
    • /
    • 1988
  • 고정 AC 전력전원에서 PWN(Pulse Width Modulation) 기법은 전압과 기본파 주파수를 가변 시키는 데 이용되어 왔다. 종래의 PWN 기법은 전류수, 필터크기 등의 문제점 때문에 PWN 출력 전압파형을 모터 구동 등의 제어 대상에 응용하는 연구가 진행되었다. 그러나 본 논문에서는 출력단 고속 스윗칭 소자를 사용하여 캐리어 주파수를 10(KHz)-45(KHz)까지 정현 PWN 시키고, 인버터의 출력단 파형은 소용량LPF(Low Pass Filter)를 사용하여 PAM(Pulse Amplitude Modulation)을 얻어냈다. 정현 PWN 제어 회로는 속응성과 제어성을 고려하여 마이크로 프로세서와 아날로그 회로로 혼합구성 하였다. 그리고 실험 결과는 변조도 0.6-1.0까지 변할 때 전압 파형을 관찰했다.

  • PDF

하이브리드 Cascade 5-레벨 PWM 인버터를 이용한 정지형 무효전력 보상기의 동작특성 (Operating Characteristics of Static Var Compensator Using Hybrid Cascade 5-level PWM Inverter)

  • 최남섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.318-321
    • /
    • 2002
  • 본 논문에서는 고전압 대용량 응용에 적합한, 하이브리드 cascade 5-레벨 PWM 인버터를 이용한 정지형 무효전력보상기가 제안된다. 또한, 제안된 시스템을 회로 DQ 모델링하고 이로부터 시스템의 중요한 동작특성을 해석하고 각종 관련 식들을 유도한다. 제안된 무효전력보상기는 대용량으로 구성 이 가능하고, 대용량-저주파 스위칭을 하는 GTO와 소용량-고주파 스위칭을 하는 IGBT등 서로 다른 종류의 스위치를 섞어 사용하는 하이브리드 구성의 장점을 가지므로 전력반도체 스위치의 활용도를 극대화 할 수 있다. 본 논문에서는 제안된 정지형 무효전력보상기의 회로구성과 특성이 설명 및 해석되고, 이를 PSIM 회로 시뮬레이션으로 그 동작특성 해석의 타당성을 입증한다.

  • PDF

보조권선을 사용한 자동차 헤드라이트용 고압방전 등 안정기 (Automotive HID ballast using auxiliary windings)

  • 이규찬;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.595-598
    • /
    • 1999
  • A new of the automotive High Intensity Discharge(HID) lamp ballast systems is proposed. Proposed scheme is consisted of the high frequency DC-DC converter and low frequency DC-AC inverter as same as conventional HID ballast system. But this system separates ignition voltage from dc link voltage, which results to used the lower voltage rating power devices for HID lamp ballast system compared with conventional system. As a result, proposed system has a lower cost and higher efficiency.

  • PDF

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.

액티브 스너버를 이용한 고주파 용접기 컨버터 개발 (Development of Converter for High Frequency Welding Machines using Active Snubber)

  • 신준영;이재민;최승원;이준영
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.351-355
    • /
    • 2016
  • Welding machines are high-capacity systems used in a low-frequency range using IGBT. As their system is similar to a large transformer, most welding machines suffer a great loss because of hard switching and vast leakage inductance. A voltage-balancing circuit is designed to overcome these shortcomings. This circuit can reduce the transformer size by making it into a high frequency and reducing the input voltage by half and by adopting a serial structure that connects two full-bridges in a series to use a MOSFET with a good property at high frequency. In addition, a Schottky diode is used in the primary rectifier to overcome the low efficiency of most welding machines. To use the Schottky diode with a reliably relatively low withstanding voltage, an active snubber is adopted to effectively limit the ringing voltage of the diode cut-off voltage.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

Design of Gain Controller of Decoupling Control of Grid-connected Inverter with LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.124-126
    • /
    • 2008
  • Grid Connected inverter is produced current to deliver power to grid. To provide low THD current, LCL filters is effective to filter high frequency component of current output from inverter. To provide sinusoidal waveform, there are many researchers have been proposed several controllers for grid-connected inverter controllers. Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. But SRF based controller is contained cross-coupling components, which generate some difficulties to analyze. In this paper, SRF based controller is analyzed. By applying decoupling control, cross-coupling component is eliminated and single phase model of the system is obtained. Through this single phase model, gain controller is designed. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF

DTC로 구동되는 대용량 유도전동기의 토크리플 저감법 (Torque ripple reduction for High power Induction Motor driven by DTC)

  • 박영민;윤재학;한기준;최세경;정명길;이세현;이교범;송중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.369-371
    • /
    • 1999
  • A torque ripple minimization technique is proposed for high power induction motors driven by 3-level inverters with switching frequency of inverter switching elements limited around 500Hz level. It is noted that conventional DTC algorithms with torque ripple minimization scheme are devised for applications with relatively high switching frequency above 2-3kHz. A new DTC algorithm, especially for low switching frequency inverter system, illustrates relatively reduced torque ripple characteristics all over the operating speed region. Simulation results show effectiveness of the proposed control algorithm, and associated experimental works will be presented in the final paper.

  • PDF