• Title/Summary/Keyword: linear

Search Result 35,734, Processing Time 0.064 seconds

Soil Texture, Electrical Conductivity and Chemical Components of Soils under the Plastic Film House Cultivation in Northern Central Areas of Korea (중북부지역(中北部地域) 시설원예지(施設園藝地) 토양(土壤)의 토성(土性), 염농도(鹽濃度) 및 화학성분(化學成分)의 조성(組成))

  • Jung, Goo-Bok;Ryu, In-Soo;Kim, Bok-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • This survey was conducted to investigate the factors affecting on salt accumulation and chemical components of soils cultivated with horticulture crops in plastic film houses. The soil samples were taken from 40 sites in the northern central areas of Korea and were analyzed for the chemical properties and soil separates. The data were evaluated with soil texture and years of cultivation as major factors. The results are summarized as follows : 1. The chemical properties of surface soils in plastic film house were pH 5.80, EC $3.59mScm^{-1}$, O.M. 4.20%, Av. $P_2O_5$ 1,178ppm, $NO_3-N$ 180ppm, Av. $SO_4{^{2-}}$ 353ppm, $Cl^-$ 240ppm, Ex. Na 0.40me/100g. 2. Compared to the outside soil of plastic film house, the inside soil had 2.5~3 times higher contents of $NO_3-N$, Av. $SO_4{^{2-}}$ and $Cl^-$, 1.2~1.8 times higher exchangeable base elements, and 2.8 times higher electrical conductivity. But pH value of the inside soil was lower than the outside soil by 0.3 pH unit. 3. Soil texture classification showed that sandy loam, loam and silt loam were 32.5 %, 37.5 %, and 30.0 %, respectively. The contents of $NO_3-N$, Av. $SO_4{^{2-}}$, $NH_4-N$ and EC value were very high in silt loam soils. Av. $P_2O_5$ content and pH value of sandy loam soils were higher than those of silt loam and loam soils. 4. The contents of O.M. and Av. $P_2O_5$ were higher in long term cultivation, but the contents of $NO_3-N$, Av. $SO_4{^{2-}}$, $Cl^-$, Ex. Mg and Ex. Na including EC of the soil with 2~4 years cultivation were higher than those of the soil with above 5 years cultivation. 5. Multiple linear regression analysis showed that contribution degree of soil chemical properties to the EC was high in the order of $NO_3-N$ > Av. $SO_4{^{2-}}$ > Ex. Na > $Cl^-$ > Av. $P_2O_5$ > $NH_4-N$ > Ex. Mg>Ex. Ca. Among the soil chemical properties the contribution of anions was remarkably high. 6. EC value correlated with ${\sum}A$(total content of anions)as $r=0.932^{**}$ and with ${\sum}C$(total content of cations) as $r=0.452^{**}$.

  • PDF

Development of a Traffic Accident Prediction Model and Determination of the Risk Level at Signalized Intersection (신호교차로에서의 사고예측모형개발 및 위험수준결정 연구)

  • 홍정열;도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.7
    • /
    • pp.155-166
    • /
    • 2002
  • Since 1990s. there has been an increasing number of traffic accidents at intersection. which requires more urgent measures to insure safety on intersection. This study set out to analyze the road conditions, traffic conditions and traffic operation conditions on signalized intersection. to identify the elements that would impose obstructions in safety, and to develop a traffic accident prediction model to evaluate the safety of an intersection using the cop relation between the elements and an accident. In addition, the focus was made on suggesting appropriate traffic safety policies by dealing with the danger elements in advance and on enhancing the safety on the intersection in developing a traffic accident prediction model fir a signalized intersection. The data for the study was collected at an intersection located in Wonju city from January to December 2001. It consisted of the number of accidents, the road conditions, the traffic conditions, and the traffic operation conditions at the intersection. The collected data was first statistically analyzed and then the results identified the elements that had close correlations with accidents. They included the area pattern, the use of land, the bus stopping activities, the parking and stopping activities on the road, the total volume, the turning volume, the number of lanes, the width of the road, the intersection area, the cycle, the sight distance, and the turning radius. These elements were used in the second correlation analysis. The significant level was 95% or higher in all of them. There were few correlations between independent variables. The variables that affected the accident rate were the number of lanes, the turning radius, the sight distance and the cycle, which were used to develop a traffic accident prediction model formula considering their distribution. The model formula was compared with a general linear regression model in accuracy. In addition, the statistics of domestic accidents were investigated to analyze the distribution of the accidents and to classify intersections according to the risk level. Finally, the results were applied to the Spearman-rank correlation coefficient to see if the model was appropriate. As a result, the coefficient of determination was highly significant with the value of 0.985 and the ranks among the intersections according to the risk level were appropriate too. The actual number of accidents and the predicted ones were compared in terms of the risk level and they were about the same in the risk level for 80% of the intersections.

Comparison of Postoperative Adjuvant Radiation Therapy Alone vs. Chemoradiotherapy in Adenocarcinoma of the Rectum (직장암의 근치적 절제술후 보조요법의 효과 분석 - 방사선치료 단독군과 항암제 방사선 병용치료군의 비교 -)

  • Lim John Jihoon;Park Won;Seong Jinsil;Suh Chang Ok;Kim Gwi Eon;Min Jin Sik;Kim Byung Soo;Roh Jae Kyung;Chung Hyun Cheol;Kim Jooyoung
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.35-41
    • /
    • 1998
  • Purpose : To investigate the role of adjuvant chemoradiotherapy in adenocarcinoma of the rectum, we retrospectively compared the treatment results between postoperative adjuvant radiotherapy alone and combined chemoradiotherapy. Material and Methods : From October 1989 to May 1994, 141 patients with rectal carcinoma were treated by postoperative adjuvant therapy in Yonsei Cancer Center. Sixty eight patients were treated by radiation therapy alone. Seventy three patients were treated by combined chemoradiotherapy. Radiation therapy was delivered with 10 MV linear accelerator, 180cGy fraction/5 days per week. Total radiation doses were 5400cGy in the postoperative radiotherapy alone group. Three to twelve cycles of Fluorouracil(mean dose $393.9mg/m^2$) with Leucovorin($20mg/m^2$) and 5040cGy of radiation were delivered in the combined chemoradiotherapy group. Third and 4th cycle of chemotherapy were administrated during the radiation treatment in the combined group. The median follow up was 38 months with a range of 3 to 81 months. Results : The 5 year overall survival rate of radiation alone group and combined group were $60.1\%$ and $66.3\%$, respectively. The 5 year disease free survival rate of radiation aione group and combined group were $54.2\%$ and $65.5\%$, respectively There was no significant difference of overall survival and disease free survival between RT alone group and combined group(p<0.05). But the 5 year Local failure free survival rate of combined group was significantly better than radiotherapy alone group($05.8\%\;vs.\;50.3\%.\;p=0.04$). Conclusion : There was no significant difference in overall survival, disease free survival, and distant metastasis free survival between postoperative adjuvant radiotheray alone group and combinded chemoradiotherapy group. Only the Local failure free survival rate was superior in the combined treatment group. These results confirm the radiosensitizing effect of the chemotherapeutic agent in the combined chemoradiotherapy treatment.

  • PDF

The Role of Radiotherapy for Carcinomas of the Gall Bladder and Extrahepatic Biliary Duct: Retrospective Analysis (담낭 및 간외담도계 악성종양의 방사선치료결과)

  • Jeong Hyeon Ju;Lee Hyun Ju;Yang Kwang Mo;Suh Hyun Suk;Kim Re Hwe;Kim Sung Rok;Kim Hong Ryong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.43-49
    • /
    • 1998
  • Purpose : Carcinomas arising in the gall bladder(GB) or extrahepatic biliary ducts are uncommon and generally have a poor prognosis. The overall 5-year survival rates are less than $10\%$. Early experiences with the external radiation therapy demonstrated a good palliation with occasional long-term survival. The present report describes our experience over the past decade with irradiation of primary carcinomas of the gallbladder and extrahepatic biliary duct. Materials and Methods : From Feb. 1984 to Nov. 1995, thirty-three patients with carcinoma of the GB and extrahepatic biliary duct were treated with external beam radiotherapy with curative intent at our institution. All patients were treated with 4-MV linear accelerator and radiation dose ranged from 31.44Gy to 54.87Gy(median 44.25Gy), and three Patients received additional intraluminal brachytherapy(range, 25Gy to 30Gy). Twenty-seven Patients received postoperative radiation. Among 27 patients, Sixteen patients underwent radical operation with curative aim and the rest of the patients either had bypass surgery or biopsy alone. In seventeen patients, adjuvant chemotherapy was used and eleven patients were treated with 5-FU, mitomycin and leucovorin. Results : Median follow up period was 8.5 months(range 2-97 months). The overall 2-year and 5-year survival rates in all patients were $29.9\%$ and $13.3\%$ respectively. In patients with GB and extrahepatic biliary duct carcinomas, the 2-year survival rates were $34.5\%$ and $27.8\%$ respectively. Patients who underwent radical operation showed better 2-year survival rates than those who underwent palliative operation($43.8\%\;vs.\;20.7\%$), albeit statistically insignificant(p>0.05). The 2-year survival rates in Stage I and II were higher than in Stage III and IV with statistical significance(p<0.05). Patients with good performance status in the beginning showed significantly better survival rates than those with worse status(p<0.05). The 2-year survival rates in combined chemotherapy group and radiation group were $40.5\%$ and $22.0\%$ respectively. There was no statistical differences in two groups (p>0.05). Conclusion : The survival of patients with relatively lower stage and/or initial good performance was significantly superior to that of others. We found an statistically insignificant trend toward better survival in patients with radical operation and/or chemotherapy, More radical treatment strategies, such as total resection with intensive radiation and/or chemotherapy may offer a better chance for cure in selective patients with carcinoma of gall bladder and extrahepatic biliary ducts.

  • PDF

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

A study on lead exposure indices of male workers exposed to lead less than 1 year in storage battery industries (축전지 제조업에서 입사 1년 미만 남자 사원들의 연 노출 지표치에 관한 연구)

  • HwangBo, Young;Kim, Yong-Bae;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.747-764
    • /
    • 1996
  • This study intended to obtain an useful information for health management of lead exposed workers and determine biological monitoring interval in early period of exposure by measuring the lead exposure indices and work duration in all male workers (n=433 persons) exposed less than 1 year in 6 storage battery industries and in 49 males who are not exposed to lead as control. The examined variables were blood lead concentration (PBB), Zinc-protoporphyrin concentration (ZPP), Hemoglobin (HB) and personal history; also measured lead concentration in air (PBA) in the workplace. According to the geometric mean of lead concentration in the air, the factories were grouped into three categories: A; When it is below $0.05mg/m^3$, B; When it is between 0.05 and $0.10mg/m^3$, and C; When it is above $0.10mg/m^3$. The results obtained were as follows: 1. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in all male workers exposed to lead less than 1 year in storage battery industries were $29.5{\pm}12.4{\mu}g/100ml,\;52.9{\pm}30.0{\mu}g/100ml\;and\;15.2{\pm}1.1\;gm/100ml$. 2. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in control group were $5.8{\pm}1.6{\mu}g/100ml,\;30.8{\pm}12.7{\mu}g/100ml\;and\;15.7{\pm}1.6{\mu}g/100ml$, being much lower than that of study group exposed to lead. 3. The means of blood lead concentration and ZPP concentration among group A were $21.9{\pm}7.6{\mu}g/100,\;41.4{\pm}12.6{\mu}g/100ml$ ; those of group B were $29.8{\pm}11.6{\mu}g/100,\;52.6{\pm}27.9{\mu}g/100ml$ ; those of group C were $37.2{\pm}13.5{\mu}g/100,\;66.3{\pm}40.7{\mu}g/100ml$. Significant differences were found among three factory group(P<0.01) that was classified by the geometric mean of lead concentration in the air, group A being the lowest. 4. The mean of blood lead concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $24.1{\pm}12.4{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $29.2{\pm}13.4{\mu}g/100ml$ ; and it was $28.9\sim34.5{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 5. The mean of ZPP concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $40.6{\pm}18.0{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $53.4{\pm}38.4{\mu}g/100ml$ ; and it was $51.5\sim60.4{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 6. Among total workers(433 person), 18.2% had PBB concentration higher than $40{\mu}g/100ml$ and 7.1% had ZPP concentration higher than $100{\mu}g/100ml$ ; In workers of factory group A, those were 0.9% and 0.0% ; In workers of factory group B, those were 17.1% and 6.9% ; In workers of factory group C, those were 39.4% and 15.4%. 7. The proportions of total workers(433 person) with blood lead concentration lower than $25{\mu}g/100ml$ and ZPP concentration lower than $50{\mu}g/100ml$ were 39.7% and 61.9%, respectively ; In workers of factory group A, those were 65.5% and 82.3% : In workers of factory group B, those were 36.1% and 60.2% ; In workers of factory group C, those were 19.2% and 43.3%. 8. Blood lead concentration (r=0.177, P<0.01), ZPP concentration (r=0.135, P<0.01), log ZPP (r=0.170, P<0.01) and hemoglobin (r=0.096, P<0.05) showed statistically significant correlation with work duration (month). ZPP concentration (r=0.612, P<0.01) and log ZPP (r=0.614, P<0.01) showed statistically significant correlation with blood lead concentration 9. The slopes of simple linear regression between work duration(month, independent variable) and blood lead concentration (dependent variable) in workplace with low air concentration of lead was less steeper than that of poor working condition with high geometric mean air concentration of lead. The study result indicates that new employees should be provided with biological monitoring including blood lead concentration test and education about personal hygiene and work place management within $3\sim4$ month.

  • PDF

Robo-Advisor Algorithm with Intelligent View Model (지능형 전망모형을 결합한 로보어드바이저 알고리즘)

  • Kim, Sunwoong
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.2
    • /
    • pp.39-55
    • /
    • 2019
  • Recently banks and large financial institutions have introduced lots of Robo-Advisor products. Robo-Advisor is a Robot to produce the optimal asset allocation portfolio for investors by using the financial engineering algorithms without any human intervention. Since the first introduction in Wall Street in 2008, the market size has grown to 60 billion dollars and is expected to expand to 2,000 billion dollars by 2020. Since Robo-Advisor algorithms suggest asset allocation output to investors, mathematical or statistical asset allocation strategies are applied. Mean variance optimization model developed by Markowitz is the typical asset allocation model. The model is a simple but quite intuitive portfolio strategy. For example, assets are allocated in order to minimize the risk on the portfolio while maximizing the expected return on the portfolio using optimization techniques. Despite its theoretical background, both academics and practitioners find that the standard mean variance optimization portfolio is very sensitive to the expected returns calculated by past price data. Corner solutions are often found to be allocated only to a few assets. The Black-Litterman Optimization model overcomes these problems by choosing a neutral Capital Asset Pricing Model equilibrium point. Implied equilibrium returns of each asset are derived from equilibrium market portfolio through reverse optimization. The Black-Litterman model uses a Bayesian approach to combine the subjective views on the price forecast of one or more assets with implied equilibrium returns, resulting a new estimates of risk and expected returns. These new estimates can produce optimal portfolio by the well-known Markowitz mean-variance optimization algorithm. If the investor does not have any views on his asset classes, the Black-Litterman optimization model produce the same portfolio as the market portfolio. What if the subjective views are incorrect? A survey on reports of stocks performance recommended by securities analysts show very poor results. Therefore the incorrect views combined with implied equilibrium returns may produce very poor portfolio output to the Black-Litterman model users. This paper suggests an objective investor views model based on Support Vector Machines(SVM), which have showed good performance results in stock price forecasting. SVM is a discriminative classifier defined by a separating hyper plane. The linear, radial basis and polynomial kernel functions are used to learn the hyper planes. Input variables for the SVM are returns, standard deviations, Stochastics %K and price parity degree for each asset class. SVM output returns expected stock price movements and their probabilities, which are used as input variables in the intelligent views model. The stock price movements are categorized by three phases; down, neutral and up. The expected stock returns make P matrix and their probability results are used in Q matrix. Implied equilibrium returns vector is combined with the intelligent views matrix, resulting the Black-Litterman optimal portfolio. For comparisons, Markowitz mean-variance optimization model and risk parity model are used. The value weighted market portfolio and equal weighted market portfolio are used as benchmark indexes. We collect the 8 KOSPI 200 sector indexes from January 2008 to December 2018 including 132 monthly index values. Training period is from 2008 to 2015 and testing period is from 2016 to 2018. Our suggested intelligent view model combined with implied equilibrium returns produced the optimal Black-Litterman portfolio. The out of sample period portfolio showed better performance compared with the well-known Markowitz mean-variance optimization portfolio, risk parity portfolio and market portfolio. The total return from 3 year-period Black-Litterman portfolio records 6.4%, which is the highest value. The maximum draw down is -20.8%, which is also the lowest value. Sharpe Ratio shows the highest value, 0.17. It measures the return to risk ratio. Overall, our suggested view model shows the possibility of replacing subjective analysts's views with objective view model for practitioners to apply the Robo-Advisor asset allocation algorithms in the real trading fields.

Development of Analytical Method for Detection of Fungicide Validamycin A Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Validamycin A의 시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Validamycin A is an aminoglycoside fungicide produced by Streptomyces hygroscopicus that inhibits trehalase. The purpose of this study was to develop a method for detecting validamycin A in agricultural samples to establish MRL values for use in Korea. The validamycin A residues in samples were extracted using methanol/water (50/50, v/v) and purified with a hydrophilic-lipophilic balance (HLB) cartridges. The analyte was quantified and confirmed by liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~0.5 ng) into a blank extract with $R^2$ > 0.99. The limits of detection and quantification were 0.005 and 0.01 mg/kg, respectively. For validation validamycin A, recovery studies were carried out three different concentration levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) with five replicates at each level. The average recovery range was from 72.5~118.3%, with relative standard deviation (RSD) less than 10.3%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the NIFDS (National Institute of Food and Drug Safety) guideline (2016). Therefore, the proposed analytical method is accurate, effective and sensitive for validamycin A determination in agricultural commodities.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.