• Title/Summary/Keyword: line resistance

Search Result 1,374, Processing Time 0.026 seconds

Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model (축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom;Kwon, Sin-Won;Gil, Kyung-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

An Evaluation of Induced Voltage according to the Grounding Resistance of a 22.9 kV-Y Distribution Line Simulated for its Field Application for Lightning Prevention (낙뢰 예방 배전선로의 현장 적용을 위해 모의된 22.9 kV-Y의 접지저항에 따른 유도전압의 평가)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.14-19
    • /
    • 2015
  • This study performed simulation tests to prevent induced lightning that occurs to a 22.9 kV-Y distribution line. A simulated distribution line reduced to 1/50 of an actual distribution line was installed to measure the induced voltage according to the change in grounding resistance. It was found that the induced voltage increased as the grounding resistance increased but that the range of its increase was small. This study examined the reliability of the proposed lightning preventive distribution line using the Minitab program (Minitab 17). When a grounding resistance of $300{\Omega}$ was maintained for each electric pole, the Anderson Darling (AD) was 0.410, the smallest, and the P value was analyzed to be 0.323, verifying that the reliability and stability were excellent. Therefore, these results will be utilized as a basis for the substantiation of a lightning preventive distribution line before its installation.

Effect of cake resistance by first-aggregation of in-line injection system (인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향)

  • KIM, Taeyoung;PARK, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

A Study on a Characteristic of the Three Friction Resistance Lines (세가지 마찰저항곡선의 특성에 관한 연구)

  • Park, Dong-Woo;Kang, Seon-Hyung;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.4
    • /
    • pp.484-495
    • /
    • 2010
  • The speed-power prediction is one of the most important functions of towing-tank facilities. Generally, ITTC-1978 extrapolation method is employed for the full-scale powering prediction. During the procedure, the friction resistance line plays a major role to predict both model- and full-scale resistance. In this paper, the form factors determined by ITTC-1957 line for several kinds of vessels are compared with the values obtained using the lines proposed by Grigson(1993) and Katsui et al.(2005). Resistance and self-propulsion coefficients predicted by three different friction resistance lines are minutely analyzed. Finally, brake powers and revolutions estimated by flat plate friction resistance lines of Grigson and Katsui et al. are compared with the results obtained from ITTC-1957 line.

Investigation on Contact Resistance of Amorphous Indium Gallium Zinc Oxide Thin Film Transistors with Various Electrodes by Transmission Line Method

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.3
    • /
    • pp.139-141
    • /
    • 2015
  • Contact resistance of interface between the channel layers and various S/D electrodes was investigated by transmission line method. Different electrodes such as Ti/Au, a-IZO, and multilayer of a-IGZO/Ag/a-IGZO were compared in terms of contact resistance, using the transmission line model. The a-IGZO TFTs with a-IGZO/Ag/a-IGZO of S/D electrodes showed good performance and low contact resistance due to the homo-junction with channel layer.

Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines (345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향)

  • Lee, Jong-Beom;Jung, Chae-Kyun;Lim, Kwang-Sik;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY (상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구)

  • Lee, Soo Ryong
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF

Influence of Process Condition on Contact Resistance in WSix Deposition (WSix 증착에서 공정조건이 contact 저항에 미치는 영향)

  • 정양희;강성준;강희순
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we discuss influence of process condition on contact resistance in WSix deposition process. In the WSix deposition process, we confirmed that word line to bit line contact resistance(WBCR) due to temperature of word line WSix deposition among various process condition split experiment. RTP treatment, d-poly ion implantation dose and thickness was estimated a little bit influence on contact resistance. Also, life time of shower head in the process chamber for WSix deposition related to contact resistance. The results obtained in this study are applicable to process control and electrical characteristics for high reliability and high density DRAM's.

  • PDF

Resistance of SOD2-transgenic petunia line to oxidative stress

  • Lee, Su-Young;Han, Bong-Hee;Kim, Yeong-Tae;Kim, Jin-Seog
    • Journal of Plant Biotechnology
    • /
    • v.37 no.4
    • /
    • pp.562-566
    • /
    • 2010
  • SOD2-transgenic $T_3$ petunia line (A2-36-2-1-1-35) was treated with different levels of methyl viologen (MV) to determine its resistance to oxidative stress. Four (4) levels of MV (0, 100, 200, and $400\;{\mu}M$) were applied. The SOD2-transgenic $T_3$ petunia line exhibited a very significant oxidative stress resistance at the highest MV concentration ($400\;{\mu}M$) treatment compared to non-transgenic plant. RNA and protein expression of SOD2 transgene and higher parenchyma cell density in the transgenic petunias exhibiting resistance to oxidative stress proves its contribution to the expression of its resistance to oxidative stress.