• Title/Summary/Keyword: kV image

Search Result 742, Processing Time 0.024 seconds

Design of Connectivity Test Circuit for a Direct Printing Image Drum

  • Jung, Seung-Min
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.43-46
    • /
    • 2008
  • This paper proposes an advanced test circuit for detecting the connectivity between a drum ring of laser printer and PCB. The detection circuit of charge sharing is proposed, which minimizes the influences of internal parasitic capacitances. The test circuit is composed of precharge circuit, analog comparator, level shifter. Its functional operation is verified using $0.6{\mu}m$ 3.3V/40V CMOS process parameter by HSPICE. Access time is100ns. Layout of the drum contact test circuit is $465{\mu}m\;{\times}\;117{\mu}m$.

THE STUDY ON THE RELATIONSHIP BETWEEN IMAGE LAYER AND IMAGE PRODUCTION OF THE ORTHOPANTOMOGRAPH. (ORTHOPANTOMOGRAPH에서 IMAGE LAYER와 상조성 관계에 대한 연구)

  • Lee Kee Taek
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-44
    • /
    • 1976
  • The study was performed in order to avoid misunderstanding of the image production in the orthopantomograph and auther tried artificially, the object was not placed on the image layer children who was in mixed dentition was taken with 3 sheets of the film at one time. The results were obtained as following; 1. If the object was placed in front of the image layer and back of it, width of the anterior teeth was narrowed and widened. 2. If the object's midline was not placed on the median line of the equipment, the one side was narrowed and the another side was widened. 3. If the head was inclined upward and downward, the former was shown V shape and the latter was shown inverted V shape outline of the arches. 4. In mixed dentition, auther obtained in each other that the image layer was placed on the deciduous arch, on the permanent arch, in the middle of the deciduous teeth and permanent teeth at one exposure.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Synthesizing Intermediate Images Using Stereoscopic Images

  • Kwak, Ji-Hyun;Komar, V.S.V.;Kim, Kyung-Tae
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.143-149
    • /
    • 2002
  • In this paper, we present an algorithm for synthesizing intermediate views from a stereoscopic pair of images. Syntheses of intermediate images allows one to realize a more comfortable the 3D display system. The proposed method is based on block matching, which is not ordinarily used. The contour information is used for a block decision. In order to find an equivalent (or corresponding) block, there are two steps: "matching of contour-to-original image" and "matching of contour-to-contour image" methods. "Matching of contour-to-contour image" uses both left and right contour images. This block matching method allows us to find the corresponding block in spite of different block sizes. Experimental results illustrate the performance of the proposed technique and we obtained a high quality image of more than 31 dB PSNR.image of more than 31 dB PSNR.

A Design of Power Management IC for CCD Image Sensor (CCD 이미지 센서용 Power Management IC 설계)

  • Koo, Yong-Seo;Lee, Kang-Yoon;Ha, Jae-Hwan;Yang, Yil-Suk
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2009
  • The power management integrated circuit(PMIC) for CCD image sensor is presented in this study. A CCD image sensor is very sensitive against temperature. The temperature, that is heat, is generally generated by the PMIC with low efficiency. Since the generated heat influences performance of CCD image sensor, it should be minimized by using a PMIC which has a high efficiency. In order to develop the PMIC with high efficiency, the input stage is designed with synchronous type step down DC-DC converter. The operating range of the converter is from 5V to 15V and the converter is controlled using PWM method. The PWM control circuit consists of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit. The saw-tooth generator is designed with 1.2MHz oscillation frequency. The comparator is designed with the two stages OP Amp. And the error amplifier has 40dB DC gain and $77^{\circ}$ phase margin. The output of the step down converter is connected to input stage of the charge pump. The output of the charge pump is connected to input of the LDO which is the output stage of the PMIC. Finally, the PMIC, based on the PWM control circuit and the charge pump and the LDO, has output voltage of 15V, -7.5V, 3.3V and 5V. The PMIC is designed with a 0.35um process.

  • PDF

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use (자외선 영상 이미지 비교를 통한 22.9kV 특고압 설비의 상태진단 연구)

  • Kim, Young-Seok;Shong, Kil-Mok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.211-213
    • /
    • 2009
  • This paper was studied about the ultra-violet rays(UV) image area and discharge quantity of 22.9kV class polymer insulator using UV camera. The UV image area was begun to observe to 60kV that is about 40% of breakdown voltage of polymer insulator and the area was increased by applied voltage. Also, the discharge quantity was increased at 60kV sharply. If the intensity of breakdown passes over about 40% we can know that need the check on the electrical facility.

  • PDF

Instagram image classification with Deep Learning (딥러닝을 이용한 인스타그램 이미지 분류)

  • Jeong, Nokwon;Cho, Soosun
    • Journal of Internet Computing and Services
    • /
    • v.18 no.5
    • /
    • pp.61-67
    • /
    • 2017
  • In this paper we introduce two experimental results from classification of Instagram images and some valuable lessons from them. We have tried some experiments for evaluating the competitive power of Convolutional Neural Network(CNN) in classification of real social network images such as Instagram images. We used AlexNet and ResNet, which showed the most outstanding capabilities in ImageNet Large Scale Visual Recognition Challenge(ILSVRC) 2012 and 2015, respectively. And we used 240 Instagram images and 12 pre-defined categories for classifying social network images. Also, we performed fine-tuning using Inception V3 model, and compared those results. In the results of four cases of AlexNet, ResNet, Inception V3 and fine-tuned Inception V3, the Top-1 error rates were 49.58%, 40.42%, 30.42%, and 5.00%. And the Top-5 error rates were 35.42%, 25.00%, 20.83%, and 0.00% respectively.

Effect of Image quality and Radiation Dose using Iterative Reconstruction in Adult and Pediatric CT: A Phantom Study (성인과 소아 CT 촬영시 IR 적용에 따른 영상화질 및 선량에 미치는 영향)

  • Ju, A-ran;Jo, Jung-Hyun;Oh, Young-Kyu;Kim, Kyoung-Ki;Lee, Soo-Been;Jeon, Pil-Hyun;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 2018
  • The main issue of CT is radiation dose reduction to patient. The purpose of this study was to estimate the image quality and dose by iterative reconstruction (IR) for adults and pediatrics. Adult and pediatric images of phantom were obtained with 120 and 140 kV, respectively, in accordance with radiation dose in terms of volume CT dose index ($CTDI_{vol}$): 10, 15, 20, 25, 30, 35 mGy. Then, the adult and the pediatric images are reconstructed by filtered-backprojection (FBP) and iterative reconstruction (IR). The images were analyzed by signal-to-noise ratio (SNR). SNR is improved when IR and 140 kV are applied to acquire adult and pediatric images. In the adult abdomen, according to diagnostic reference level, the SNR values of bone were increased about 27.84 % and 27.77 % at 120 kV and 140 kV, and the tissue's SNR values of the IR were increased about 29.84 % and 33.46 % 120 and 140 kV, respectively. Dose is reduced to 40% in adults abdomen images when using IR reconstruction. In pediatric images, the bone's SNR were also increased about 17.70% and 18.17 % at 120 kV and 140 kV. The tissue's SNR were increased about 26.73 % and 26.15 % at 120 kV and 140 kV. Radiation dose is reduced from 30% to 50% for bone and tissue images. In the case of examinations for adult and pediatric CT, IR technique reduces radiation dose to patient, and it could be applied to adult and pediatric imaging.

Analysis of Image Quality and Scan Dose when Applying Reconstruction Algorithm Changes to Chest CT Scans (흉부 CT 스캔에서 재구성 알고리즘 변화적용 시 화질과 스캔 선량 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.819-825
    • /
    • 2023
  • In this study, among chest CT examination conditions, the tube voltage was changed to 100 and 80 kVp and the reconstruction algorithm was changed to FBP, ASIR-V, and DLIR to compare and analyze changes in examination dose and image quality. As a result, when applying ASIR-V and DLIR at a tube voltage of 100 kVp, which is lower than the existing tube voltage, the dose is lowered while achieving image quality most similar to that when applying 120 kVp and FBP. especially, DLIR reconstructed images had excellent SNR and CNR at all tube voltages. In addition, the SSIM index was analyzed to be closest to 1, showing the highest similarity to the original image. Therefore, when performing repeated chest CT examinations, the application of DLIR can reduce the examination dose by about 29.7%, which is expected to help solve some of the biggest problems with CT examinations, namely radiation exposure due to the examination.