• Title/Summary/Keyword: isolation material

Search Result 409, Processing Time 0.029 seconds

Speckle Defect by Dark Leakage Current in Nitride Stringer at the Edge of Shallow Trench Isolation for CMOS Image Sensors

  • Jeong, Woo-Yang;Yi, Keun-Man
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.189-192
    • /
    • 2009
  • The leakage current in a CMOS image sensor (CIS) can have various origins. Leakage current investigations have focused on such things as cobalt-salicide, source and drain scheme, and shallow trench isolation (STI) profile. However, there have been few papers examining the effects on leakage current of nitride stringers that are formed by gate sidewall etching. So this study reports the results of a series of experiments on the effects of a nitride stringer on real display images. Different step heights were fabricated during a STI chemical mechanical polishing process to form different nitride stringer sizes, arsenic and boron were implanted in each fabricated photodiode, and the doping density profiles were analyzed. Electrons that moved onto the silicon surface caused the dark leakage current, which in turn brought up the speckle defect on the display image in the CIS.

Design Aspects of a New Reliable Torsional Switch with Excellent RF Response

  • Gogna, Rahul;Jha, Mayuri;Gaba, Gurjot Singh;Singh, Paramdeep
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • This paper proposes a metal contact RF MEMS switch which utilizes a see-saw mechanism to acquire a switching action. The switch was built on a quartz substrate and involves vertical deflection of the beam under an applied actuation voltage of 5.46 volts over a signal line. The see-saw mechanism relieves much of the operation voltage required to actuate the switch. The switch has a stiff beam eliminating any stray mechanical forces. The switch has an excellent isolation of −90.9 dB (compared to − 58 dB in conventional designs ), the insertion of −0.2 dB, and a wide bandwidth of 88 GHz (compared to 40 GHz in conventional design ) making the switch suitable for wide band applications.

Design and Graphic Simulation of a Cleaning Robot for a Radioactive Environment Application

  • Kim, K.;Park, J.;M. Yang;C. Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.161.3-161
    • /
    • 2001
  • This paper describes design features of a cleaning robot for use in a radioactive zone of the Isolation room of the Irradiated Material Examination Facility (IMEF) at Korea Atomic Energy Research Institute (KAERI). This cleaning robot is intended to completely eliminate human interaction with hazardous radioactive contaminants. The clean ing robot that is operated either by manual mode or by autonomous mode is designed to be capable of cleaning the isolation room´s floor surface and collecting dry nuclear fuel debris and other radioactive waste placed on the floor. The functional, mechanical and electrical design considerations of the cleaning robot in terms of remote cleanup operation and remote maintenance at a radioactive environment are presented. A graphical representation of the cleaning ...

  • PDF

Sound Transmission Loss Maximization of Multi-panel Structures Lined with Poroelastic Materials by Topology Optimization (전달손실 최대화를 위한 흡음재-패널 배열 최적설계)

  • Kim, Yong-Jin;Lee, Joong-Seok;Kang, Yeon-June;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.728-733
    • /
    • 2008
  • Though multi-panel structures lined with a poroelastic material have been widely used to reduce sound transmission in various fields, most of the previous works to design them were conducted by repeated analyses or experiments based on initially given configurations or sequences. Therefore, it was difficult to obtain the optimal sequence of multi-panel structures lined with a poroelastic material yielding superior sound isolation capability. In this work, we propose a new design method to sequence a multi-panel structure lined with a poroelastic material having maximized sound transmission loss. Being formulated as a one-dimensional topology optimization problem for a given target frequency, the optimal sequencing of panel-poroelastic layers is systematically carried out in an iterative manner. In this method, a panel layer is expressed as a limiting case of a poroelastic layer to facilitate the optimization process. This means that main material properties of a poroelastic material are treated as Interpolated functions of design variables. The designed sequences of panel-poroelastic layers were shown to be significantly affected by the target frequencies; more panel layers were used at higher target frequencies. The sound transmission loss of the system was calculated by the transfer matrix derived from Biot's theory.

  • PDF

A Disparate Low Loss DC to 90 GHz Wideband Series Switch

  • Gogna, Rahul;Jha, Mayuri;Gaba, Gurjot Singh;Singh, Paramdeep
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.92-97
    • /
    • 2016
  • This paper presents design and simulation of wide band RF microswitch that uses electrostatic actuation for its operation. RF MEMS devices exhibit superior high frequency performance in comparison to conventional devices. Similar techniques that are used in Very Large Scale Integration (VLSI) can be employed to design and fabricate MEMS devices and traditional batch-processing methods can be used for its manufacturing. The proposed switch presents a novel design approach to handle reliability concerns in MEMS switches like dielectric charging effect, micro welding and stiction. The shape has been optimized at actuation voltage of 14-16 V. The switch has an improved restoring force of 20.8 μN. The design of the proposed switch is very elemental and primarily composed of electrostatic actuator, a bridge membrane and coplanar waveguide which are suspended over the substrate. The simple design of the switch makes it easy for fabrication. Typical insertion and isolation of the switch at 1 GHz is -0.03 dB and -71 dB and at 85 GHz it is -0.24 dB and -29.8 dB respectively. The isolation remains more than - 20 db even after 120 GHz. To our knowledge this is the first demonstration of a metal contact switch that shows such a high and sustained isolation and performance at W-band frequencies with an excellent figure-of merit (fc=1/2.pi.Ron.Cu =1,900 GHz). This figure of merit is significantly greater than electronic switching devices. The switch would find extensive application in wideband operations and areas where reliability is a major concern.

A Study on the Electrical Characteristics of Ultra Thin Gate Oxide

  • Eom, Gum-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.5
    • /
    • pp.169-172
    • /
    • 2004
  • Deep sub-micron device required to get the superior ultra thin gate oxide characteristics. In this research, I will recommend a novel shallow trench isolation structure(STI) for thin gate oxide and a $N_2$O gate oxide 30 $\AA$ by NO ambient process. The local oxidation of silicon(LOCOS) isolation has been replaced by the shallow trench isolation which has less encroachment into the active device area. Also for $N_2$O gate oxide 30 $\AA$, ultra thin gate oxide 30 $\AA$ was formed by using the $N_2$O gate oxide formation method on STI structure and LOCOS structure. For the metal electrode and junction, TiSi$_2$ process was performed by RTP annealing at 850 $^{\circ}C$ for 29 sec. In the viewpoints of the physical characteristics of MOS capacitor, STI structure was confirmed by SEM. STI structure was expected to minimize the oxide loss at the channel edge. Also, STI structure is considered to decrease the threshold voltage, result in a lower Ti/TiN resistance( Ω /cont.) and higher capacitance-gate voltage(C- V) that made the STI structure more effective. In terms of the TDDB(sec) characteristics, the STI structure showed the stable value of 25 % ~ 90 % more than 55 sec. In brief, analysis of the ultra thin gate oxide 30 $\AA$ proved that STI isolation structure and salicidation process presented in this study. I could achieve improved electrical characteristics and reliability for deep submicron devices with 30 $\AA$ $N_2$O gate oxide.

The study on the development of phase shifter of FBAR(Film Bulk Acoustic Reonator) Duplexer using photo lithograry (후막 리소그라피 공정을 이용한 FBAR Duplexer용 phase shifter 개발에 관한 연구)

  • Yoo, Joshua;Yoo, M.J.;Kim, Erick;Lee, W.S.;Park, J.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.768-771
    • /
    • 2003
  • Nowadays, the study on the ceramic components and modules used in telecommunication system is being performed. Duplexer is the one of the most important components and has the role of dividing Rx and Tx signal. Duplexer including the FBAR is being done vigorously LTCC is used for package like SAW package, duplexer package. In our research, LTCC material is used for FBAR duplexer package and photo-lithography for the fine line phase shifter. The good characteristics, low loss and good isolation, of duplexer is obtained by the fine line phase shifter having high characteristic impedance of stripline.

  • PDF

Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials (감쇠재 사용에 따른 중량충격음의 소음 및 진동특성)

  • Jeon, Jin-Yong;Jeong, Young;Song, Hee-Soo;Kim, Min-Bae;Lee, Young-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF

Analysis of Heavy Metal Concentration on Working Clothes for Waste Incinerating Workers (생활폐기물 소각장 작업복의 중금속 분석)

  • Park, Soon-Ja
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.1
    • /
    • pp.39-53
    • /
    • 2007
  • The purpose of this study was to determine the characteristics of an experimental protective clothing material with regard to comfort and isolation from the hazardous heavy metals produced in municipal waste incineration. An analysis was conducted on the total concentrations of heavy metals in some parts such as surface, middle layer, and interior for the treated fabric, and the untreated one, and working clothes. We conclude that the processed fabric with charcoal for working clothes showed the least exposure to heavy metals of the three. Working clothes worn by workers during waste incineration were much more contaminated than the untreated and treated materials. The material of working clothes could be chosen according to the function with regard to its original chemical characteristics, which are the proper results of the dyeing process. The processed fabric material has high degrees of moisture regain, thermal insulation, water vapor penetration, and antibacterial function; consequently, it is much more comfortable to wear. The fabric material proposed in this research contributed much more to blocking heavy metal concentrations (such as Cd, Pb, Cu, Cr, Zn, Mn) than did the fabric of working clothes at present. Consequently, we strongly suggest that the material of working clothes be upgraded by adopting the above-mentioned charcoal-processed fabric. Materials of working clothes must be improved to increase comfort and prevent harmful gas, flying dust, and heavy metals from permeating the fabrics.

  • PDF

A Behavior Test on a Frictional-Wedge-Type Vibration Isolation Device for Vibration Reduction of a Railway Track (열차 진동 저감을 위한 마찰쐐기형 방진장치의 거동 시험)

  • Lee, Chanyoung;Choi, Sanghyun;Lee, Yooin;Kwon, Segon;Koh, Yongsung;Ji, Yongsoo
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2015
  • In the case of railway facilities in cities such as a railway station or a bridge, the significance of design for reducing vibration and noise is getting more significant. The vibration control solution is in need especially for an elevated railway station to block vibration of a train and secondary noise effectively. Even though a vertical vibration isolation device is able to be applied effectively to railway facilities such as elevated railway stations which transfer vibration directly from a train to a structure, the development of the vertical device is much slower than a horizontal vibration isolation device. In this paper, a vibration isolation device using wedge type friction material which is currently developing to reduce train-induced vibration effectively is introduced and test results for verification of dynamic performance is also presented. The vibration test on a concrete structure equipped with the developed vibration isolation device is conducted through which the isolation performance and dynamic properties are verified and needs for improving the performance of the device is identified.