• 제목/요약/키워드: integration length

검색결과 234건 처리시간 0.029초

DYNAMICAL CHARACTERISTICS OF THE QUIET TRANSITION REGION: SPATIAL CORRELATION STUDIES OF H I 931 AND S VI 933 UV LINES

  • YUN HONG SIK;CHAE JONG CHUL;POLAND A. I.
    • 천문학회지
    • /
    • 제31권1호
    • /
    • pp.1-17
    • /
    • 1998
  • To understand the basic physics underlying large spatial fluctuations of intensity and Doppler shift, we have investigated the dynamical charctersitics of the transition region of the quiet sun by analyzing a raster scan of high resolution UV spectral band containing H Lyman lines and a S VI line. The spectra were taken from a quiet area of $100'\times100'$ located near the disk center by SUMER on board SOHO. The spectral band ranges from 906 A to 950 A with spatial and spectral resolution of 1v and $0.044 {\AA}$, respectively. The parameters of individual spectral lines were determined from a single Gaussian fit to each spectral line. Then, spatial correlation analyses have been made among the line parameters. Important findings emerged from the present analysis are as follows. (1) The integrated intensity maps of the observed area of H I 931 line $(1\times10^4 K)$ and S VI 933 line $(2\times10^5 K)$ look very smilar to each other with the same characterstic size of 5". An important difference, however, is that the intensity ratio of brighter network regions to darker cell regions is much larger in S VI 933 line than that in H I 931 line. (2) Dynamical features represented by Doppler shifts and line widths are smaller than those features seen in intensity maps. The features are found to be changing rapidly with time within a time scale shorter than the integration time, 110 seconds, while the intensity structure remains nearly unchanged during the same time interval. (3) The line intensity of S VI is quite strongly correlated with that of H I lines, but the Doppler shift correlation between the two lines is not as strong as the intensity correlation. The correlation length of the intensity structure is found to be about 5.7' (4100 km), which is at least 3 times larger than that of the velocity structure. These findings support the notion that the basic unit of the transition region of the quiet sun is a loop-like structure with a size of a few $10^3 km$, within which a number of unresolved smaller velocity structures are present.

  • PDF

29GHz 국부 발진 신호용 MMIC 주파수 체배기의 설계 및 제작 (Design and fabrication of the MMIC frequency doubler for 29 GHz local oscillator application)

  • 김진성;이성대;이복형;김성찬;설우석;임병옥;김삼동;박현창;박형무;이진구
    • 대한전자공학회논문지TC
    • /
    • 제38권11호
    • /
    • pp.63-70
    • /
    • 2001
  • 밀리미터파 대역에서 안정적이고 경제적인 local oscillator (LO) 신호를 생성하기 위한 주파수 체배기를 설계 및 제작하였다. 주파수 체배기는 14.5 GHz를 입력받아 29 GHz를 생성하도록 설계되었으며, 측정 결과 14.5 GHz에서 S11이 -9.2 dB, 29 GHz에서 S22가 -18.6 dB 로 입력 측은 14.5 GHz에, 출력 측은 29GHz에 매칭이 되었다. 변환손실의 경우 14.5 GHz에서 입력전력 6 dBm일 때 최소 값인 18.2 dB를 보였으며, 출력 단에서의 주파수 스펙트럼 특성은 14.5 GHz에서 15.2dB의 값을 나타내었다. 또한 입력신호의 isolation특성은 10.5 GHz에서 18.5GHz까지 주파수 범위에서 30 dB이상의 값을 보였다. 제작된 MMIC(Microwave monolithic integrated circuits) 주파수 체배기의 칩 사이즈는 $1.5{\times}2.2\;mm^2$이다.

  • PDF

패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석 (Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm)

  • 정민기;김성민;김명주;이종호;명훈;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권3호
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

플로어플랜 기법에 따른 3차원 멀티코어 프로세서의 성능, 전력효율성, 온도 분석 (Analysis of Performance, Energy-efficiency and Temperature for 3D Multi-core Processors according to Floorplan Methods)

  • 최홍준;손동오;김종면;김철홍
    • 정보처리학회논문지A
    • /
    • 제17A권6호
    • /
    • pp.265-274
    • /
    • 2010
  • 공정기술 발달로 인해 칩 내부 집적도가 크게 증가하면서 내부 연결망이 멀티코어 프로세서의 성능 향상을 제약하는 주된 원인이 되고 있다. 내부 연결망에서의 지연시간으로 인한 프로세서 성능 저하 문제를 해결하기 위한 방안 중 하나로 3차원 적층 구조 설계 기법이 최신 멀티코어 프로세서를 설계하는데 있어서 큰 주목을 받고 있다. 3차원 적층 구조 멀티코어 프로세서는 코어들이 수직으로 쌓이고 각기 다른 층의 코어들은 TSV(Through-Silicon Via)를 통해 상호 연결되는 구성으로 설계된다. 2차원 구조 멀티코어 프로세서에 비해 3차원 적층 구조 멀티코어 프로세서는 내부 연결망의 길이를 감소시킴으로 인해 성능 향상과 전력소모 감소라는 장점을 가진다. 하지만, 이러한 장점에도 불구하고 3차원 적층 구조 설계 기술은 증가된 전력 밀도로 인해 발생하는 프로세서 내부 온도 상승에 대한 적절한 해결책이 마련되지 않는다면 실제로는 멀티코어 프로세서 설계에 적용되기 어렵다는 한계를 지니고 있다. 본 논문에서는 3차원 멀티코어 프로세서를 설계하는데 있어서 온도 상승 문제를 해결하기 위한 방안 중 하나인 플로어플랜 기법을 다양하게 적용해 보고, 기법 적용에 따른 프로세서의 성능, 전력효율성, 온도에 대한 상세한 분석 결과를 알아보고자 한다. 실험 결과에 따르면, 본 논문에서 제안하는 온도를 고려한 3가지 플로어플랜 기법들은 3차원 멀티코어 프로세서의 온도 상승 문제를 효과적으로 해결함과 동시에, 플로어플랜 변경으로 데이터 패스가 바뀌면서 성능이 저하될 것이라는 당초 예상과는 달리, 온도 하락으로 인해 동적 온도 제어 기법의 적용 시간이 줄어들면서 성능 또한 향상시킬 수 있음을 보여준다. 이와 함께, 온도 하락과 실행 시간 감소로 인해 시스템에서의 전력 소모 또한 줄일 수 있을 것으로 기대된다.

표층해류 신속예측을 위한 회선적분법의 적용 (Application of a Convolution Method for the Fast Prediction of Wind-Induced Surface Current in the Yellow Sea and the East China Sea)

  • 강관수;정경태
    • 한국해안해양공학회지
    • /
    • 제7권3호
    • /
    • pp.265-276
    • /
    • 1995
  • 본 논문에서는 실시간 해황예보 시스템 개발의 일환으로 수행된 회선적분법을 이용한 신속 표층유속 재현에 대하여 다룬다. 바람응력은 공간적으로 균일하고 대 기압은 무시된다. Data Base 구축을 위하여 4방향의 바람(북서, 북동, 남서, 남동)을 고려하여 각 지점의 회선적분의 가중치를 Galerkin-FEM 모형에 의해 계산하였다. 시간에 따른 바람응력이 주어지면 구성된 Data Base를 이용하여 회선적분법에 의해 신속한 예보가 가능하다. 시간적으로 변하는 임의의 바람응력은 6시간 단위로 정의되는 wind pulse의 연속으로 표현되며 총 12개의 pulse(즉, 72시간전)가 convolution product에 사용된다. 회선적분법의 적용 가능성을 확인하기 위하여 황해 이상화한 해역과 황해와 동지나해에 이르는 실제 해역에서의 수치실험이 수행되었다. 고려한 바람응력은 역풍류 생성 확인을 위하여 시간에 따라 sin 함수적으로 변하는 북풍을 고려하였고, 실험 결과 역풍류 생성의 화인과 회선적분법을 이용한 신속 표층해류 예측 가능성을 확인할 수 있었다.

  • PDF

임플란트 환자의 유형 및 분포에 대한 연구 (The Study of Implant Patient's Type and Implant Distribution)

  • 홍성재;백정원;김창성;최성호;이근우;채중규;김종관;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.539-554
    • /
    • 2002
  • It has been approximately 40 years since $Br{{\aa}}nemark$ first introduced osseo-integration for implants in the early 1960s. Unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. Thus, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The following results on patients type and implant distribution were compiled from 1814 implant cases of 640 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2001. 1. There are no dissimilarities between men and women, with patients in their 40,50s accounting for 49% of patients and 56% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 59% of implant treatments followed by Mx. posterior area(21%), Mx anterior area(l4%) and Mn anterior area 2%. 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 98% and fully edentulous patient accounted for the remaining 2% 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Compared to women, men are more likely to suffer from tooth loss due to periodontal disease. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. The distribution of bone quality for maxillae was 52% for type III, followed by 23% for type II, 20% for type IV and 0% for type I. As for mandible, the distribution was 52% for type II, followed by 37% for type III, 7% for type IV and 4% for type I. 6. The distribution of bone quantity for maxillae was 49% for type C, followed by 34% for type B, 14% for type D, 3% for type A, and 0% for type E. As for mandible, the distribution was 52% for type B, followed by 35% for type C, 6% for type D, 3% for type A and 0% for type E. 7. The majority of implants were those of 10-14mm in length (80%) and regular diameter in width (79%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

서울시 상업 젠트리피케이션 발생 주거지역의 입지적 요인과 변화특성 분석 (An Analysis of Locational Characteristics and Business Change in the Commercially Gentrified Residential Areas in Seoul, Korea)

  • 이기훈;이수기;천상현
    • 지역연구
    • /
    • 제34권1호
    • /
    • pp.31-47
    • /
    • 2018
  • 본 연구는 서울시 상업 젠트리피케이션 발생 주거지역의 입지적 요인과 변화 특성을 로짓모형을 활용하여 분석하였다. 분석결과로 서울시 상업 젠트리피케이션 발생 주거지역은 단독주택 연면적 비율이 높고 근린생활시설이 많은 주거지역에서 발생하는 것으로 나타났다. 이에 더하여, 고속도로 및 지하철 입구와 대학교 그리고 많은 사람을 끌어들일 수 있는 인구 집중시설과 거리가 가까운 곳에서 발생하는 것으로 나타났다. 주거지역 내 상업 젠트리피케어션이 발생한 집계구의 도로 특성은 도로 길이가 길고, 도로 면적이 작으며, 도로망 네트워크의 부분 통합도 값이 크고, 3지 교차로가 많은 집계구에서 발생하는 것으로 나타났다. 이러한 결과는 서울시 상업 젠트리피케이션 발생 주거지역이 골목길과 같은 유기적 도로망과 단독주택 위주의 낮은 주거밀도 그리고 인구유발시설과의 접근성이 좋은 곳에서 발생하는 것을 의미한다. 이어서 서울시 상업 젠트리피케이션 발생 주거지역의 변화특성을 살펴보면, 2006년과 비교하여 2014년에 커피숍과 주점이 증가하고 근린생활시설의 수는 감소한 것으로 나타났다. 또한, 주점과 한식 음식점의 폐업기간은 2006년과 비교하여 2014년에 짧아지는 것으로 나타났다. 본 연구는 서울시 상업 젠트리피케이션 발생 주거지역에 대한 입지특성과 토지이용변화를 토대로 주거지역의 상업 젠트리피케이션에 대한 정책적 시사점을 제시하였다.

코어와 L2 캐쉬의 수직적 배치 관계에 따른 3차원 멀티코어 프로세서의 온도 분석 (Analysis on the Temperature of 3D Multi-core Processors according to Vertical Placement of Core and L2 Cache)

  • 손동오;안진우;박재형;김종면;김철홍
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권6호
    • /
    • pp.1-10
    • /
    • 2011
  • 멀티코어 프로세서를 설계하는데 있어서 구성요소들을 연결하는 와이어 길이의 증가로 인한 지연 현상은 성능향상에 큰 걸림돌이 되고 있다. 멀티코어 프로세서의 와이어 지연 문제를 해결하기 위하여 최근에는 3차원 구조의 멀티코어 프로세서 설계 기술이 많은 주목을 받고 있다. 3차원 구조 멀티코어 프로세서 설계 기술은 코어들을 수직으로 적층함으로써, 물리적인 연결망 길이를 크게 감소시켜 성능향상과 함께 연결망에서 소비되는 전력을 줄일 수 있다. 하지만 많은 전력을 소모하는 회로를 수직으로 적층함으로써 전력밀도가 증가하여 프로세서 내부의 온도가 크게 상승하는 문제를 가지고 있다. 본 논문에서는 3차원 구조 멀티코어 프로세서에서의 발열문제를 해결 할 수 있는 플로어플랜 방법을 제안하기 위해 칩 내부에 적층되는 코어의 수직적 배치 형태를 다양하게 변화시키면서 그에 따른 온도 변화를 살펴보고자 한다. 실험 결과를 통해, 프로세서 내부의 온도 감소를 위해서는 코어와 L2 캐쉬를 수직으로 인접하게 적층함으로써 코어의 온도를 낮추는 기법이 매우 효과적임을 알 수 있다. 코어와 코어가 수직으로 상호 인접하는 플로어플랜과 비교하여, 코어와 L2 캐쉬를 수직으로 인접하게 배치시키는 기법이 4-레이어 구조의 경우에는 평균 22%, 2-레이어 구조의 경우 평균 13%의 온도 감소 효과를 보임을 알 수 있다.

지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향 (Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis)

  • 박현수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성 (Characteristics of Fluoride Releasing of Anodized Titanium Implant)

  • 김하영;송광엽;배태성
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.361-369
    • /
    • 2008
  • 본 연구의 목적은 다공성의 티타늄 산화막에 불소를 처리한 결과를 평가하는 것이다. 디스크에 양극산화법을 통하여 다공성의 티타늄산화막표면을 얻은 후 불소를 처리하고 일정시간동안 Hank액에 침전을 시켰다. 양극산화를 통해 일정거칠기의 표면을 얻었으며 SEM과 XRD를 통하여 표면의 형상과 성분을 분석하였다. 생성된 표면은 빠른 표면 활성도를 보였으며, 적절한 거칠기와 좋은 골반응으로 골유착에 기여할 수 있을 것으로 여겨진다.