• Title/Summary/Keyword: integral solution

Search Result 607, Processing Time 0.033 seconds

Analysis of 2-D Potential Problem with L-shape Domain by p-Convergent Boundary Element Method (p-수렴 경계요소법에 의한 L-형 영역을 갖는 2차원 포텐셜 문제 해석)

  • Woo, Kwang-Sung;Jo, Jun-Hyung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.117-124
    • /
    • 2009
  • The p-convergent boundary element method has been proposed to analyze two-dimensional potential problem on the basis of high order Legendre shape functions that have different property comparing with the shape functions in conventional boundary element method. The location of nodes corresponding to high order shape function are not defined along the boundary, called by nodeless node, similar to the p-convergent finite element method. As the order of shape function increases, the collocation point method is used to solve linear simultaneous equations. The collocation patterns of p-convergent boundary element method consist of non-symmetric hierarchial or symmetric non-hierarchical. As the order of shape function increases, the number of collocation point increases. The singular integral that appears in p-convergent boundary element has been calculated by special numeric quadrature technique and semi-analytical integration technique. The L-shape domain problem including singularity in the vicinity of reentrant comer is analyzed and the numerical results show that the relative error is smaller than $10^{-2}%$ range as compared with other results in literatures. In case of same condition, the symmetric p-collocation point pattern shows high accuracy of solution.

A study on the estimation of bubble size distribution using an acoustic inversion method (음향 역산법을 이용한 기포의 크기 분포 추정 연구)

  • Park, Cheolsoo;Jeong, So Won;Kim, Gun Do;Moon, Ilsung;Yim, Geuntae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.151-162
    • /
    • 2020
  • This paper presents an acoustic inversion method for estimating the bubble size distribution. The estimation error of the attenuation coefficient represented by a Fredholm integral equation of the first kind is defined as an objective function, and an optimal solution is found by applying the Levenberg-Marquardt (LM) method. In order to validate the effectiveness of the inversion method, numerical simulations using two types of bubble distribution are performed. In addition, a series of experiments are carried out in a water tank (1.0 m × 0.54 m × 0.6 m), using bubbles generated by three different generators. Images of the distributed bubbles are obtained by a high-speed camera, and the insertion losses of the bubble layer are measured using a source and a hydrophone. The image is post-processed to glance a distribution characteristics of each bubble generator. Finally, the size distribution of bubbles is estimated by applying the inversion method to the measured insertion loss. From the inversion results, it was observed that the number of bubbles increases exponentially as the bubble size decreases, and then increases again after the local peak at 70 ㎛ - 120 ㎛.

A Study on the Relationship Between Length of Time and Contamination in Open Intravenous Solutions (정맥주사용 수액의 개방후 시간경과에 따른 오염도에 관한 실험연구)

  • 김일원
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.1
    • /
    • pp.67-80
    • /
    • 1986
  • The use of intravenous solutions for fluid replacement has become an integral part of patient care, This widespread use of intravenous solutions has increased the risk of contamination that can lead to septicemia and phlebitis. The literature regarding contamination of in use intravenous solutions recommends a standard 24-hour time limit on the use of these fluids. But the desings of these studies did not incorporate a time variable related to contamination. In other studies, however, time was a manipulated variable: but data regarding the onset of contamination were conflicting. Because published reports conflict with regard to a time standard related to the use of intravenous therapy, additional empirical data are needed upon which to base the standards of care regulating use of intravenous therapy. This study investigated rate of contamination in simulated in-use intravenous solutions to obtain data from which to recomend a standard time period for the administration of intravenous solutions. In this study samples were drawn from 60 bottles of 5% D/W solution at predetermined time intervals over 48 hours and samples were inoculated to Thio-glychollate Broth. After 10 days' culturing in that Broth, samples were cultured on blood agar plates for 18∼48 hours to determine the rate of contamination. was found at all time Period, regardless of the presence or absence of nurse's gloving in the preparation of fluids, the location in which the experimentations were performed, the contamination level of surrounding air, or the length of time during which solutions were opened. Data from this study support the use of a 48-hour time period on which to base the standard involved in ready-to-use simple intravenous solutions without additives. In emergency departments and critical care areas where intravenous solutions are prepared in advance, the suggested time standard supported by the data generated from this study is 48 hours, not 24 hour. Data from this study support a 24-hour time standard for changing in-use intravenous solutions when the contamination results from the manipulation of intravenous infusion system by hospital personnel, or from some other exogenous sources during administration. Because contamination that does occur within 48 hours in intravenous solutions must be introduced from some exogenous sources, further empirical studies based on the identification of sources of contamination and factors that affect the rate of contamination, are needed to investigate the currently employed standard of intravenous therapy and to provide the patient with more efficient and safer intravenous thereapy.

  • PDF

How to Change Korean Water Management System? : Focused on Expert's Recognition Analysis (물 관리 행정체계 어떻게 바뀌어야 하는가? : 전문가 인식조사를 중심으로)

  • Kim, Cheol Hoi
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.266-277
    • /
    • 2013
  • Climate change asks the government to make changes in water management system. Although water demand is increasing according to urbanization, clean and safe water supply is limited. Therefore efficient water management is one of the key issues. Korean water management system is evaluated inefficient because it is executed by five different ministries. This study reviewed previous literature about Korean water management system, analysed present function sharing among 5 ministries, and conducted survey on improvement of water management system. Experts recognized that the most important problem of water policy is the failure of policy coordination among Ministries, and the solution of it is to make a new integral organization or to integrate related functions into one Ministry. Based on them, this study conclude that the central government functions related with water management need to be integrated on a new organization or Ministry of Environment focused on water quality improvement in the light of preservation instead of development.

An efficient 2.5D inversion of loop-loop electromagnetic data (루프-루프 전자탐사자료의 효과적인 2.5차원 역산)

  • Song, Yoon-Ho;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2008
  • We have developed an inversion algorithm for loop-loop electromagnetic (EM) data, based on the localised non-linear or extended Born approximation to the solution of the 2.5D integral equation describing an EM scattering problem. Source and receiver configuration may be horizontal co-planar (HCP) or vertical co-planar (VCP). Both multi-frequency and multi-separation data can be incorporated. Our inversion code runs on a PC platform without heavy computational load. For the sake of stable and high-resolution performance of the inversion, we implemented an algorithm determining an optimum spatially varying Lagrangian multiplier as a function of sensitivity distribution, through parameter resolution matrix and Backus-Gilbert spread function analysis. Considering that the different source-receiver orientation characteristics cause inconsistent sensitivities to the resistivity structure in simultaneous inversion of HCP and VCP data, which affects the stability and resolution of the inversion result, we adapted a weighting scheme based on the variances of misfits between the measured and calculated datasets. The accuracy of the modelling code that we have developed has been proven over the frequency, conductivity, and geometric ranges typically used in a loop-loop EM system through comparison with 2.5D finite-element modelling results. We first applied the inversion to synthetic data, from a model with resistive as well as conductive inhomogeneities embedded in a homogeneous half-space, to validate its performance. Applying the inversion to field data and comparing the result with that of dc resistivity data, we conclude that the newly developed algorithm provides a reasonable image of the subsurface.

Thermal and Electrical Behaviors of Polyethylene Oxide/Polyaniline Fibers Prepared by Electrospinning Method (전기방사법에 의해 제조된 폴리에틸렌옥사이드/폴리아닐린 섬유의 열적 및 전기적 거동)

  • Kim, Seok;Cho, Mi-Hwa;Park, Soo-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.16-21
    • /
    • 2006
  • In this study, PEO blend fibers mixed with polyaniline (PANI)/10-camphor sulfonic acid (CSA) and PANI/dodecylbenzene sulfonic acid (DBSA) were electro spun to investigate the influence of PANI content. CSA and DBSA were used as a functionalized doping acid having a bulky volume. PANI/PEO blend solution was prepared by dissolving PEO and PANI doped with CSA or DBSA. The thermal properties were measured by thermogravimetric analyzer (TGA). As a result, with increasing of the PANI content in PANI/CSA and PANI/DBSA, although initial decomposition temperature (IDT) was decreased, thermal stability was increased due to the increase of $A^*{\cdot}K^*$ and integral procedural decomposition temperature (IPDT). The electrical conductivities measured by the 4-probe method. The electric conductivity was increased with increasing of PANI content in PANI/CSA and PANI/DBSA. However, electrical conductivity did not change significantly beyond 30% content of PANI. From CV results, PANI/CSA showed the better defined peak shpae and higher peak current density compared to PANI/DBSA. This was probably related to the slightly higher electrical conductivity or better morphology for easy charge transfer in the case of PANI/CSA.

Suitability evaluation of magnesium substituted biphasic calcium phosphates prepared by coprecipitation method (공침법을 이용한 마그네슘이 첨가된 biphasic calcium phosphate의 적합성 평가)

  • Lee, Hyoung-Sin;Kim, Tae-Wan;Kim, Dong-Hyun;Park, Hong-Chae;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.237-242
    • /
    • 2010
  • Magnesium-substituted BCP (biphasic calcium phosphate) powders were prepared by incorporating small amounts of magnesium into the structure of different hydroxyapatite (HAp)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) ratios through coprecipitation method. A series of magnesium substitutions ranging from 0, 0.5, and 1.0 wt%, which are comparable to the measured magnesium contents, were performed. The obtained powders were characterized by the following analytical techniques: X-ray diffraction analysis (XRD), Thermo Gravimetric Analyzer (TGA) and Fourier transform infrared spectroscopy (FT-IR). The results have shown that substitution of magnesium in the calcium-deficient apatites resulted in the formation of biphasic mixtures of different HAP/${\beta}$-TCP ratios after heating above $1000^{\circ}C$. The 1.0 wt% magnesiumsubstituted-BCP were soaked in Hank's solutions after 2 weeks to observe the morphology of the biocement, especially needle-like hydroxyapatite crystals and to estimate the length and diameter of nanoneedle crystals.

Reliability Assessment Based on an Improved Response Surface Method (개선된 응답면기법에 의한 신뢰성 평가)

  • Cho, Tae Jun;Kim, Lee Hyeon;Cho, Hyo Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.21-31
    • /
    • 2008
  • response surface method (RSM) is widely used to evaluate th e extremely smal probability of ocurence or toanalyze the reliability of very complicated structures. Althoug h Monte-Carlo Simulation (MCS) technique can evaluate any system, the procesing time of MCS dependson the reciprocal num ber of the probability of failure. The stochastic finite element method could solve thislimitation. However, it is limit ed to the specific program, in which the mean and coeficient o f random variables are programed by a perturbation or by a weigh ted integral method. Therefore, it is not aplicable when erequisite programing. In a few number of stage analyses, RSM can construct a regresion model from the response of the c omplicated structural system, thus, saving time and efort significantly. However, the acuracy of RSM depends on the dist ance of the axial points and on the linearity of the limit stat e functions. To improve the convergence in exact solution regardl es of the linearity limit of state functions, an improved adaptive response surface method is developed. The analyzed res ults have ben verified using linear and quadratic forms of response surface functions in two examples. As a result, the be st combination of the improved RSM techniques is determined and programed in a numerical code. The developed linear adapti ve weighted response surface method (LAW-RSM) shows the closest converged reliability indices, compared with quadratic form or non-adaptive or non-weighted RSMs.

Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants (원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.339-345
    • /
    • 2008
  • The heat exchanger tube in nuclear power plants is mainly fabricated from nonferromagnetic material such as a copper, titanium, and inconel alloy, but the moisture separator & reheater tube in the turbine system is fabricated from ferromagnetic material such as a carbon steel or ferrite stainless steel which has a good mechanical properties in harsh environments of high pressure and temperature. Especially, the moisture separator & reheater tubes, which use steam as a heat transfer media, typically employ a tubing with integral fins to furnish higher heat transfer rates. The ferromagnetic tube typically shows superior properties in high pressure and temperature environments than a nonferromagnetic material, but can make a trouble during the normal operation of power plants because the ferrous tube has service-induced damage forms including a steam cutting, erosion, mechanical wear, stress corrosion cracking, etc. Therefore, nondestructive examination is periodically performed to evaluate the tube integrity. Now, the remote field testing(RFT) technique is one of the solution for examination of ferromagnetic tube because the conventional eddy current technique typically can not be applied to ferromagnetic tube such as a ferrite stainless steel due to the high electrical permeability of ferrous tube. In this study, we have designed RFT probes, calibration standards, artificial flaw specimen, and probe pusher-puller necessary for field application, and have successfully carry out RFT examination of the moisture separator & reheater tube of nuclear power plants.

A Study on the Corrosion Prevention of the Integral Series Generator for Military Vehicles (군용차량용 엔진일체형 직렬 발전기 부식 방지에 관한 연구)

  • Kang, Tae-Woo;Kim, Seong-Gon;Shin, Cheol-Ho;Lee, Kye-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.74-79
    • /
    • 2019
  • The military vehicle produces electric power through an engine-integrated serial hybrid generator that is connected to the engine and does not have a separate generator installation space. However, depending on the mechanical characteristics of the connection between the generator and the engine, iron oxide for internal rusting and lubrication grew scattered. The iron oxide is adhered to the starter to deteriorate the starting performance, and there is a problem that the noise of the leg due to wear of the gear is increased. To solve this problem, the connection spline material and the surface treatment of the engine were improved and the shape was changed to a grease sealing type to prevent the generation of iron oxide inside. As the shape of the generator connector composing the shafting system was changed, the integrity of the structure was confirmed through the torsional endurance test. In addition, through the actual vehicle load test, it was verified that no corrosion occurred during the target life span without internal corrosion. It was confirmed that the anti-scattering structure of the grease effectively suppresses the generation of iron oxide, thereby reducing the noise generated from the generator. In this paper, we propose a fundamental solution to the degradation of the starter and the noise generation by preventing the back corrosion caused by the serial hybrid generator installed between the engine and the transmission.